使用Fast2test公司推出的93-Tall-Mass-Timber-Buildings考試學習資料,您將發現與真實考試95%相似的考試問題和答案,以及我們升級版之后的International Code Council 93-Tall-Mass-Timber-Buildings題庫,覆蓋率會更加全面。我們的專家為你即將到來的考試提供學習資源,不僅僅在于學習, 更在于如何通過93-Tall-Mass-Timber-Buildings考試。如果你想在IT行業擁有更好的發展,擁有高端的技術水準,International Code Council 93-Tall-Mass-Timber-Buildings是確保你獲得夢想工作的唯一選擇,為了實現這一夢想,趕快行動吧!
| Section | Objectives |
|---|---|
| Topic 1: Construction Fire Safety | |
| Topic 2: Structural & Connection Inspection | - Connection Design and Protection - Framing and Structural Elements |
| Topic 3: General & Construction Types | - Construction Classification — Type IV-A, IV-B, IV-C
|
| Topic 4: Mass Timber Materials | - CLT, Glulam, NLT, SCL and Engineered Wood Products |
| Topic 5: Fire-Resistance & Protection | - Concealed Spaces Protection - Noncombustible Protection & Encapsulation - Fire-Resistance-Rated Assemblies |
| Topic 6: Inspection Duties & Documentation | - Inspection Reporting and Compliance Verification - Statement of Special Inspections |
>> 93-Tall-Mass-Timber-Buildings考試重點 <<
當你準備93-Tall-Mass-Timber-Buildings考試的時候,盲目地學習與考試相關的知識是很不理想的學習方法。其實想要通過考試是有竅門的。如果你使用了好的工具,不僅可以節省很多的時間,還能得到輕鬆通過考試的保證。如果你想问什么工具,那当然是Fast2test的93-Tall-Mass-Timber-Buildings考古題了。
問題 #37
The fire-resistance of a protected mass timber assembly is equivalent to the fire resistance time of the:
答案:C
解題說明:
The fire resistance of a protected mass timber element is determined by adding the inherent fire resistance of the mass timber to the protection time contributed by the approved noncombustible protection. Therefore, option D is correct.
The mass timber component provides structural endurance through its large cross section and predictable charring behavior. The noncombustible protection delays heating, ignition, and charring of the protected timber surfaces. Its contribution may be established by testing or by assigned values permitted under IBC Section 722.7. The combined value must equal or exceed the rating required for the building element.
Option A ignores the additional protection contribution. Option B ignores the structural endurance provided by the timber after the protective membrane has performed its assigned function. Option C incorrectly substitutes "finish rating time." A finish rating measures temperature rise behind a protective membrane and is not automatically the same as the added fire-resistance contribution established for protected mass timber.
Inspection must confirm that the protection system matches the approved calculation or tested configuration, including material type, thickness, layer count, fastening, edge treatment, joints, penetrations, and continuity.
References/Topics: 2021 IBC Sections 703.6, 703.8 and 722.7; protected mass timber performance method and noncombustible protection contribution.
問題 #38
Which of the following products is not included in the definition of mass timber?
答案:D
解題說明:
Prefabricated wood I-joists are engineered wood framing products, but they are not mass timber elements because their configuration does not meet the minimum solid cross-sectional dimensions required for Type IV mass timber construction. Option B is therefore correct.
An I-joist consists of relatively thin flanges connected by a thin structural web. Its efficient open- web-like cross section is fundamentally different from a large solid, laminated, built-up or panelized timber element. I- joists are separately regulated by IBC Section 2303.1.2 and are manufactured and evaluated in accordance with ASTM D5055.
Solid-sawn lumber can qualify as mass timber when it satisfies the minimum heavy-timber dimensions.
Structural glued-laminated timber is a recognized large-section engineered timber product, while cross- laminated timber is explicitly recognized as a panelized mass timber product and is regulated by ANSI/APA PRG 320.
The critical inspection point is that the term "engineered wood" does not automatically mean "mass timber." The special inspector must verify the product category, minimum dimensions, approved construction type, applicable product standard, identification marks and installation requirements shown in the approved construction documents.
References/Topics: 2021 IBC Chapter 2 definition of "Mass Timber"; Sections 2303.1.2, 2303.1.3, 2303.1.4 and 2304.11; ASTM D5055.
問題 #39
In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:
答案:B
解題說明:
A 7/16-inch wood structural panel does not satisfy the prescribed minimum thickness for fireblocking.
Therefore, option C is the exception.
IBC Section 718.2.1 permits one thickness of 23/32-inch wood structural panel where the joints are properly backed. A 7/16-inch panel is substantially thinner and cannot be substituted without an approved alternative- material determination. The code also recognizes one-half-inch gypsum board and properly installed batts or blankets of mineral wool or other approved materials.
Mass timber complying with Section 2304.11 is also permitted as fireblocking. Its large cross section provides resistance to the movement of flame, hot gases, and smoke through a concealed space that is at least equivalent to the nominal lumber traditionally accepted for this purpose.
The inspector must distinguish fireblocking from a tested firestop system. Fireblocking divides or interrupts concealed combustible cavities; it does not automatically protect a penetration through a fire-resistance-rated wall or floor. Installation must completely fill or close the required space, remain securely supported, and comply with requirements for joints, edges, penetrations, and mineral-fiber compression.
References/Topics: 2021 IBC Section 718.2.1; Section 2304.11; approved fireblocking materials in mass timber construction.
問題 #40
Which of the following is true regarding Type IV-B unprotected portions of mass timber ceilings and walls?
答案:C
解題說明:
Type IV-B construction is fundamentally protected mass timber construction, but the 2021 IBC permits specifically limited areas of interior mass timber to remain exposed. Section 602.4.2.2.2 establishes two independent exposure limits. Unprotected portions of mass timber ceilings, including attached beams, are limited to 20 percent of the floor area of the dwelling unit or fire area. Unprotected portions of mass timber walls, including attached columns, are limited to 40 percent of that floor area . Accordingly, option C correctly states the permitted percentages.
These percentages do not operate in isolation. Exposed areas must also comply with Section 602.4.2.2.4, which establishes separation requirements between unprotected mass timber surfaces. Where both walls and ceilings are exposed within the same dwelling unit or fire area, Section 602.4.2.2.3 requires use of the mixed- unprotected-area equation rather than independently maximizing both percentages.
Option A describes neither Type IV-B nor its controlled-exposure concept. Option B incorrectly characterizes Type IV-B as requiring complete encapsulation. Option D reverses the ceiling and wall percentages.
References/Topics: 2021 IBC Sections 602.4.2.2.2, 602.4.2.2.3 and 602.4.2.2.4; Type IV-B permitted exposed mass timber.
問題 #41
Periodic special inspection of sealants or adhesives shall be conducted where sealants or adhesives are part of a mass timber building element as designated in the approved construction documents.
All of the following statements are correct in reference to sealants or adhesives in mass timber buildings except:
答案:C
解題說明:
Option C is the incorrect statement. The sealing inspection requirements in IBC Section 1705.20 do not automatically apply to every item classified as a "joint" under Section 202. They apply specifically where a sealant or adhesive required by Section 703.7 is installed on mass timber building elements identified in the approved construction documents.
Section 703.7 addresses abutting edges and intersections of fire-resistance-rated mass timber elements and intersections between mass timber and other materials where both elements require a fire-resistance rating.
These conditions require periodic special inspection because continuity of the air seal affects the fire performance assumed for the timber assembly.
Option A is correct: qualifying sealants must comply with ASTM C920. Option B is also correct: adhesives used for this purpose must comply with ASTM D3498. Option D reflects the required inspection of sealant applications at the prescribed abutting edges and intersections, although the technically precise term is "mass timber building elements." Fire-resistant joint systems are governed separately by IBC Section 715 and may require inspection under Section 1705.18. The two inspection categories must not be treated as interchangeable.
References/Topics: 2021 IBC Sections 703.7, 715, 1705.18 and 1705.20; ASTM C920; ASTM D3498.
問題 #42
......
為了幫助你準備93-Tall-Mass-Timber-Buildings考試認證,我們建議你有健全的知識和經驗93-Tall-Mass-Timber-Buildings考試,我們Fast2test設計的問題,可以幫助你輕鬆獲得認證,Fast2test International Code Council的93-Tall-Mass-Timber-Buildings考試的自由練習測試,93-Tall-Mass-Timber-Buildings考試問題及答案,93-Tall-Mass-Timber-Buildings考古題,93-Tall-Mass-Timber-Buildings書籍,93-Tall-Mass-Timber-Buildings學習指南。