International Code Council 93-Tall-Mass-Timber-Buildings Exam Syllabus Topics:

SectionObjectives
Topic 1: Tall Mass Timber Building Code Provisions- Special Inspection Requirements
  • 1. Inspection of connections and protective measures
    • 2. Special inspection of mass timber construction
      - Type IV Construction
      • 1. Construction Types IV-A, IV-B and IV-C
        • 2. Heights, Stories and Allowable Areas
          - Applicable Codes and References
          • 1. International Fire Code
            • 2. International Building Code
              • 3. Mass Timber Buildings and the IBC
                - Fire Safety and Fire Resistance
                • 1. Fire protection systems and construction fire safety
                  • 2. Fire-resistance ratings and noncombustible protection
                    - Structural and Connection Requirements
                    • 1. Mass timber structural systems
                      • 2. Connections and connection protection
                        - Mass Timber Products and Definitions

                        >> 93-Tall-Mass-Timber-Buildings試験内容 <<

                        93-Tall-Mass-Timber-Buildings合格内容、93-Tall-Mass-Timber-Buildings受験内容

                        あなたは今International Code Councilの93-Tall-Mass-Timber-Buildings試験のために準備していますか。そうであれば、あなたは夢がある人だと思います。我々JPNTestはあなたのような人に夢を叶えさせるという目標を持っています。我々の開発するInternational Code Councilの93-Tall-Mass-Timber-Buildingsソフトは最新で最も豊富な問題集を含めています。あなたは我々の商品を購入したら、一年間の無料更新サービスを得られています。我々のソフトを利用してInternational Code Councilの93-Tall-Mass-Timber-Buildings試験に合格するのは全然問題ないです。

                        International Code Council 93-Tall-Mass-Timber-Buildings 認定 93-Tall-Mass-Timber-Buildings 試験問題 (Q51-Q56):

                        質問 # 51
                        Refer to the exhibit by clicking on the EXHIBIT button above.

                        Given: The connections between the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, and wood cover is designed per AWC Technical Report 10 to provide the entire 2 hours of protection.
                        The bearing area between the CLT and glulam is the minimum required.
                        What are the minimum dimensions, in inches, for the wood block shown in red?

                        正解:D

                        解説:
                        Under the illustrated connection detail, the minimum wood-block dimensions are 3 inches by 3 inches.
                        Therefore, option C is correct.
                        The block is part of the sacrificial wood-cover system used to protect the connection for the full two-hour fire- resistance period. It must provide sufficient timber beyond the protected connection region to account for calculated charring and the increased exposure that can develop at the interface between abutting wood members. Because the problem states that the CLT-to-glulam bearing area is already the minimum required, the primary members do not provide surplus material that can be credited as additional protection at that edge.
                        AWC connection-fire-design guidance requires the protective geometry to remain effective after the calculated char front advances. Char contraction can open a gap at abutting edges and expose material deeper in the connection than would occur on an uninterrupted planar surface. The 3-inch-by-3-inch block maintains the required protective envelope for the stated two-hour condition.
                        This dimension is specific to the illustrated configuration and assumptions; it is not a universal minimum for every mass timber connection. The inspector must verify the approved detail rather than substitute nominal blocking based solely on field availability.
                        References/Topics: AWC Technical Report 10; AWC Fire Design Specification provisions for wood-cover protection and char contraction at abutting members.


                        質問 # 52
                        Which of the following is an acceptable alternative for protecting structural connections from fire in Type IV- A, IV-B or IV-C construction?

                        正解:A

                        解説:
                        Option D directly reflects the engineering-analysis method authorized by 2021 IBC Section 2304.10.1. For structural connections in Type IV-A, IV-B, or IV-C construction, the analysis must demonstrate that temperatures at every relevant portion of the connection remain within prescribed limits for a period corresponding to the fire-resistance rating required of the connected structural element.
                        The code establishes two critical temperature-rise limits: an average rise of not more than 250°F and a maximum rise of not more than 325°F . For this purpose, the "connection" includes the connectors, fasteners, and those portions of the wood members that participate structurally in the connection.
                        Option A is incorrect because ASTM E136 is a test for determining whether a material is noncombustible; it is not the fire-resistance test method for a structural connection. Option B is not a code-recognized substitute for the required connection fire evaluation. Option C is insufficient because a manufacturer's generalized fire- performance representation does not establish the required code fire-resistance duration unless supported through an approved test, evaluation, or engineering analysis.
                        References/Topics: 2021 IBC Section 2304.10.1; engineering-analysis method for Type IV-A, IV-B, and IV- C structural connections.


                        質問 # 53
                        Materials acceptable for use in fire-protecting connections in Type IV-A construction includes each of the following except:

                        正解:D

                        解説:
                        Steel plates are not themselves a fire-protective material for the connection; therefore, option A is the exception. Steel plates frequently form part of mass timber structural connections, but because steel is highly thermally conductive, exposed steel can rapidly transmit heat into fasteners and adjacent wood. Consequently, the steel connection components are normally the items that require protection , not the material relied upon to provide that protection.
                        AWC guidance recognizes wood cover, fire-rated gypsum board, and other approved protection materials as valid means of shielding structural connections. TR10 specifically provides calculation procedures and worked examples using sacrificial wood cover and Type X gypsum wallboard. An approved protective coating can also be used where its documented fire-performance characteristics establish the required endurance under the approved design.
                        The distinction is important for inspection. A concealed steel plate does not automatically mean a protected connection. The special inspector must verify whether sufficient wood cover, gypsum protection, approved coating, or another engineered protection system surrounds the steel for the required duration. Hardware geometry, exposed edges, gaps, and penetrations can all materially affect thermal performance.
                        References/Topics: AWC Technical Report No. 10, protection of structural connections; 2021 IBC Section
                        2304.10.1; AWC guidance that connection protection can be provided by wood cover, gypsum board, or other approved material.


                        質問 # 54
                        Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:

                        正解:D

                        解説:
                        Option A is the incorrect statement and therefore the required answer. Under 2021 IBC Table 601, an exterior bearing wall in Type IV-C construction requires a two-hour fire-resistance rating , not one hour.
                        The tall mass timber classifications progressively vary the degree of noncombustible protection and allowable exposure, but the structural fire-resistance requirements remain substantial. Type IV-A exterior bearing walls require three hours. Type IV-B exterior bearing walls require two hours. Type IV-C exterior bearing walls also require two hours. Thus, options B, C, and D correctly reproduce the Table 601 values.
                        The special inspector must also recognize that Table 601 is not necessarily the only rating criterion affecting an exterior wall. Exterior walls are additionally subject to the requirements associated with fire separation distance, particularly Table 705.5. Where another IBC provision requires a higher rating, that more restrictive condition controls.
                        For mass timber construction, compliance also depends on the prescribed protective system, member dimensions, connections, joints, intersections, and exterior-side protection. A wall cannot be accepted as compliant solely because the timber cross section appears substantial; it must conform to the approved rated design.
                        References/Topics: 2021 IBC Section 601; Table 601; Section 602.4; Table 705.5.


                        質問 # 55
                        Calculated mass timber fire resistance can include each of the following except:

                        正解:B

                        解説:
                        Minimum prescriptive dimensions are not themselves a component added into a calculated fire-resistance time. Therefore, option A is the exception.
                        IBC Section 602.4 states that a mass timber element's required fire resistance can be based on the fire- resistance contribution of the mass timber, the noncombustible protection, or a combination of those two components. Options B, C, and D reflect those permitted approaches.
                        Minimum dimensions under Section 2304.11 serve a different function. They establish the minimum cross- sectional size and construction characteristics required for qualifying heavy timber or mass timber elements.
                        A member can satisfy the minimum dimensional requirement without automatically achieving every required one-, two-, or three-hour fire-resistance rating. The structural fire calculation must evaluate the remaining effective section after charring, elevated-temperature effects, applied loading, and any credited protective materials.
                        The inspector must therefore verify both requirements independently: the installed member must meet the minimum code dimensions and must match the approved fire-resistance design. Increasing a member to the minimum prescriptive size does not by itself replace the required calculation, tested assembly, or approved protection system.
                        References/Topics: 2021 IBC Sections 602.4, 703.2, 722.7 and 2304.11; calculated mass timber fire resistance.


                        質問 # 56
                        ......

                        93-Tall-Mass-Timber-Buildings認定試験問題には、高品質と効率に加えて、非常に高品質のサービスがあります。 93-Tall-Mass-Timber-Buildingsテスト準備を使用すると、能力を向上させながら非常に楽しい経験をすることができます。私たちは常に最初に顧客を提唱しています。あなたの目標を達成するために93-Tall-Mass-Timber-Buildings学習教材を使用する場合、私たちは光栄に思います。また、93-Tall-Mass-Timber-Buildings pdfファイルにより、学習効率が向上し、限られた時間で最高の結果を得ることができます。 93-Tall-Mass-Timber-Buildings pdfファイルは、選択する必要がある最高の試験ツールです。