| Section | Objectives |
|---|---|
| Topic 1: Chimneys and Vents | - Connectors and Terminations
|
| Topic 2: General Administration | - Code Scope and Administration
|
| Topic 3: Combustion Air and Fuel Supply | - Combustion Air
|
| Topic 4: Heating and Cooling Systems | - Heating Appliances
|
| Topic 5: Materials and Specifications | - Approved Materials
|
| Topic 6: Ventilation and Exhaust Systems | - Commercial Kitchens
|
| Topic 7: Hydronic Piping and Refrigeration | - Refrigeration
|
| Topic 8: Duct Systems | - Duct Construction
|
International Code Council인증 M2시험을 준비하기 위해 잠도 설쳐가면서 많이 힘들죠? Itcertkr덤프가 고객님의 곁을 지켜드립니다. Itcertkr에서 제공해드리는International Code Council인증 M2덤프는 실제International Code Council인증 M2시험문제를 연구하여 만든 공부자료이기에 최고의 품질을 자랑합니다. Itcertkr덤프를 열심히 공부하여 멋진 IT전문가의 꿈을 이루세요.
질문 # 12
An 8-inch Type B venting system with a listed vent cap must terminate a minimum of _____ feet above the flat roof through which it passes.
정답:C
설명:
For a Type B gas vent with a listed vent cap terminating through a flat roof , the minimum required termination height is 1 foot above the roof . That makes Option A correct. This is consistent with gas vent termination tables used with listed Type B vent systems and the code framework for Type B vent terminations.
질문 # 13
What is the minimum air velocity that must be provided by an exhaust duct system serving a Type I range hood?
정답:D
설명:
For commercial kitchen exhaust associated with Type I hood systems, the recognized code-based minimum duct transport velocity is 1,500 feet per minute , so C is the correct answer. Option B uses the wrong unit, and the other listed velocities do not match the code minimum used for this question type.
질문 # 14
Termination of vents for appliances listed for and installed outdoors that incorporate integral venting shall:
정답:D
설명:
For appliances listed for outdoor installation and incorporating integral venting , the IMC requires them to be installed in accordance with their listings and the manufacturer's installation instructions . That matches Option C exactly.
질문 # 15
Supports for hazardous exhaust duct shall be constructed of:
정답:D
질문 # 16
Given: single-wall vent, which serves only one appliance, and has a height of 10 feet.
The maximum horizontal length permitted for a 5-inch diameter vent connector serving this vent is _____ feet.
정답:A
설명:
For a single-wall vent connector serving one appliance, the maximum horizontal length is determined from the vent connector sizing and length rules. For a 5-inch diameter connector with a 10-foot vent height , the permitted maximum horizontal length is 7.5 feet . Therefore, Option B is correct.
질문 # 17
......