BTW, DOWNLOAD part of TestPassed NCM-MCI-6.10 dumps from Cloud Storage: https://drive.google.com/open?id=1xhSgDIlRPB7A671syMjSthMxPJ1KJuHu
Our Nutanix NCM-MCI-6.10 dumps assists the candidates of the test with its three formats to advance their preparation as per various learning needs. A team of experts at TestPassed has designed the NCM-MCI-6.10 Pdf Format to help applicants who are too busy to prepare intensively for the Nutanix NCM-MCI-6.10 certification exam on the first go.
| Section | Weight | Objectives |
|---|---|---|
| Business Continuity and Disaster Recovery | 15% | - Disaster recovery strategy implementation - BCDR testing and validation - Failover and failback operations - Replication and recovery configuration |
| Advanced Platform Configuration and Troubleshooting | 25% | - Cluster management, expansion and maintenance - Integration with third-party systems - Prism Central and Prism Element configuration - Security configuration and compliance - API and CLI-based operations |
| Analyze and Optimize Storage Performance | 20% | - Evaluate and resolve competing workload requirements - Optimize storage configuration and settings - Understand storage internals and I/O patterns - Troubleshoot storage performance bottlenecks |
| Monitoring, Automation and Operational Efficiency | 5% | - Operational process optimization - Automation workflows and tools - Monitoring and alerting configuration |
| Network Performance and Security | 20% | - Implement and analyze Flow security policies - Tune overlay networking and traffic flow - Optimize physical and virtual network configurations - Network troubleshooting and optimization |
| Virtualization and VM Performance Optimization | 15% | - VM resource adjustment and optimization - Performance metrics analysis and tuning - AHV administration and workload management - High availability and migration management |
>> NCM-MCI-6.10 Exam Details <<
Are you ready to gain all these Nutanix NCM-MCI-6.10 certification benefits? Looking for a simple, smart, and quick way to pass the challenging Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI) exam? If your answer is yes then you need to enroll in the NCM-MCI-6.10 exam and prepare well to crack this NCM-MCI-6.10 Exam with good scores. In this career advancement journey, you can get help from TestPassed. The TestPassed will provide you with real, updated, and error-free NCM-MCI-6.10 Exam Dumps that will enable you to pass the final Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI) exam easily.
NEW QUESTION # 23
An administrator needs to configure a new write-intensive MS-SQL VM on Cluster 1.
VM specifications:
* vCPU: 12
* vRAM: 128GB
* Storage: 100 GB OS, 750 GB Data
Create the VM and any objects needed in the current environment to meet requirements, maximizing performance for the production environment. Include NEWSQL in the name of any new objects.
Production environment:
* 4 nodes
* Each node has two 8-core CPUs
* Each node has 1024 GB RAM
* Storage: 4 × 7.16 TB SSD Disks and 8 × 8 TB HDD disks
Make sure the VM is configured for maximum performance for the production environment.
Note: Network configuration is not required at this time. Do not power on the VM.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to create the high-performance SQL VM on Cluster 1.
This task requires two phases: first, creating a new all-flash storage container, and second, creating the VM with a specific vNUMA and disk controller configuration for maximum performance.
1. Access Cluster 1 Prism Element
* From the main Prism Central dashboard, navigate to Hardware > Clusters.
* Find Cluster 1 in the list and click its name. This will open the specific Prism Element login page for that cluster.
* Log in to Cluster 1's Prism Element interface.
2. Create the All-Flash Storage Container
To maximize performance for a "write-intensive" workload on a hybrid cluster, the data and log disks must be placed on an all-flash container.
* In the Cluster 1 PE interface, click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Storage.
* Click the + Storage Container button.
* Fill in the basic details:
* Name: NEWSQL_Flash_Container
* Click Advanced Settings.
* Scroll down to the Storage Tier section.
* Select the SSD radio button. This pins all data in this container to the SSD tier, ensuring all-flash performance.
* Click Save.
3. Create and Configure the VM
Now, create the VM, applying vNUMA and multi-SCSI controller best practices.
* From the main PE dashboard, navigate to the VM view.
* Click the + Create VM button.
* Enter the compute details. This configuration is critical for vNUMA performance, as it tells the VM's guest OS about the underlying physical NUMA topology (2 CPUs with 8 cores each).
* Name: NEWSQL_VM
* vCPUs: 12
* Number of Sockets: 2
* Cores per vCPU: 6 (This creates a 2-socket, 6-core VM, totaling 12 vCPUs)
* Memory: 128 GB
* Scroll down to the Disks section and add the OS disk:
* Click + Add New Disk.
* Storage Container: Select the default (hybrid) container.
* Size: 100 GB
* Bus: SCSI
* Device Index: 0 (This will be scsi.0)
* Click Add.
* Add the Data disk (on its own controller for parallel processing):
* Click + Add New Disk.
* Storage Container: Select NEWSQL_Flash_Container.
* Size: 750 GB
* Bus: SCSI
* Device Index: 1 (This creates a new controller, scsi.1)
* Click Add.
* Add a Log disk (on its own controller, a best practice for "write-intensive" SQL):
* Click + Add New Disk.
* Storage Container: Select NEWSQL_Flash_Container.
* Size: 100 GB (A common size for a log disk)
* Bus: SCSI
* Device Index: 2 (This creates a third controller, scsi.2)
* Click Add.
* Review the configuration: You should now have three disks attached, each on a separate controller (scsi.
0, scsi.1, scsi.2). This provides the maximum I/O performance.
* Ensure the Power on VM after creation box is unchecked.
* Click Save.
Topic 1, Performance Based Questions Set 1
Environment
You have been provisioned a dedicated environment for your assessment which includes the following:
Initial Steps
* When you first log into Prism Central or Prism Element you may see the EULA screen. Accept the EULA with any name and then disable Pulse.
* To access Prism Element, the pass-through from Prism Central
(Infrastructure\Hardware\Clusters\cluster-x\Launch Prism Element) works better than directly using the external IP:9440.
Workstation
* Windows Server 2019
* All software/tools/etc to perform the required tasks
* Nutanix Documentation and whitepapers can be found in Desktop\Files\Documentation and Desktop\Files\Documentation 6.10
* Note that the Workstation is the system you are currently logged into
* Windows Server 2019
* All software/tools/etc to perform the required tasks
* Nutanix Documentation and whitepapers can be found in Desktop\Files\Documentation and Desktop\Files\Documentation 6.10
* Note that the Workstation is the system you are currently logged into Nutanix Cluster
* There are two clusters provided, connected to one Prism Central. The connection information for the relevant cluster will be displayed to the right of the question. Please make sure you are working on the correct cluster for each item. Please ignore any licensing violations.
Important Notes
* If the text is too small and hard to read, or you cannot see all of the GUI, you can increase/decrease the zoom of the browser with CTRL + and CTRL - (the plus and minus keys).
Prism Central Web Console
* admin / ykZUCJMER7V*
* nutanix / UJ2xE!DEXGY
Cluster 1
* CVM external IP: 34.53.118.63
* CVM DR IP: 172.30.0.6
* admin / 9Fw0B!3QH4X)
* nutanix / GNP*FE2504XWZ
* root / KR*6HY0z5E8
Cluster 2
* CVM external IP: 34.82.155.5
* CVM DR IP: 172.30.0.4
* admin / 5*K30fA76X
* nutanix / N*3F%1ME!Z7T9
NEW QUESTION # 24
Task 16
An administrator is working to create a VM using Nutanix V3 API calls with the following specifications.
* VM specifications:
* vCPUs: 2
* Memory: BGb
* Disk Size: 50Gb
* Cluster: Cluster A
* Network: default- net
The API call is falling, indicating an issue with the payload:
The body is saved in Desktop/ Files/API_Create_VM,text
Correct any issues in the text file that would prevent from creating the VM. Also ensure the VM will be created as speeded and make sure it is saved for re-use using that filename.
Deploy the vm through the API
Note: Do not power on the VM.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
https://portal.nutanix.com/page/documents/kbs/details?targetId=kA00e000000LLEzCAO
https://jsonformatter.curiousconcept.com/#
acli net.list (uuid network defult_net)
ncli cluster info (uuid cluster)
Put Call: https://Prism Central IP address : 9440/api/nutanix/v3vms
Edit these lines to fix the API call, do not add new lines or copy lines.
You can test using the Prism Element API explorer or PostMan
Body:
{
{
"spec": {
"name": "Test_Deploy",
"resources": {
"power_state":"OFF",
"num_vcpus_per_socket": ,
"num_sockets": 1,
"memory_size_mib": 8192,
"disk_list": [
{
"disk_size_mib": 51200,
"device_properties": {
"device_type":"DISK"
}
},
{
"device_properties": {
"device_type":"CDROM"
}
}
],
"nic_list":[
{
"nic_type": "NORMAL_NIC",
"is_connected": true,
"ip_endpoint_list": [
{
"ip_type": "DHCP"
}
],
"subnet_reference": {
"kind": "subnet",
"name": "default_net",
"uuid": "00000000-0000-0000-0000-000000000000"
}
}
],
},
"cluster_reference": {
"kind": "cluster",
"name": "NTNXDemo",
"uuid": "00000000-0000-0000-0000-000000000000"
}
},
"api_version": "3.1.0",
"metadata": {
"kind": "vm"
}
}
https://www.nutanix.dev/2019/08/26/post-a-package-building-your-first-nutanix-rest-api-post-request/ Reference
NEW QUESTION # 25
An administrator regularly sees a WARN for backup_schedule_check and also receives alerts for Pulse not being enabled on Cluster 1.
Detailed information for backup_schedule_check:
Node xx.xx.xx.xx:
WARN: Backup schedule(s) exist for protection domain NoVMs; however, there are no entities in the protection domain.
Refer
to KB 1910 (http://portal.nutanix.com/kb/1910) for details on backup_schedule_check or Recheck with: ncc health_checks data_protection_checks protection_domain_checks backup_schedule_check.
This shows up in NCC, however, it is something set up by the company and they do not want the NCC check to be run.
Configure Cluster 1 to no longer have messages in NCC about the backup_schedule_check.
Turn off the alert for Pulse not being enabled, and resolve the alert. They would like messages about Pulse to be recorded, but do not want an alert.
Note: You may need to run the "Pulse is not enabled" check in order to have one to resolve.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to configure Cluster 1 from its Prism Element interface.
1. Disable the backup_schedule_check NCC Check
This will prevent the WARN message for the NoVMs protection domain.
* Log in to the Cluster 1 Prism Element (PE) interface.
* Navigate to the Health dashboard (click the "heart" icon in the top-left).
* In the left-hand menu, select NCC.
* In the search bar for the checks, type backup_schedule_check to find the specific check.
* Select the checkbox next to the backup_schedule_check in the list.
* Click the Disable button that appears above the table. This will stop this check from running during NCC health reports.
2. Configure and Resolve Pulse Alerts
This process involves two parts: disabling the alerting policy, and then enabling Pulse itself to resolve the underlying condition.
A. Disable the Alert Policy
This stops the system from generating a new alert if Pulse is ever disabled, satisfying the "do not want an alert" requirement.
* Click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Alert Policies.
* In the search bar, type Pulse to find the policy.
* Select the checkbox for the alert policy named Pulse is not enabled (or pulse_disabled_alert).
* Click the Update button.
* Uncheck the Enable box for the policy.
* Click Save.
B. Enable Pulse (to Resolve the Condition)
This enables the Pulse service to record messages (as requested) and fixes the root cause of the alert, allowing it to be resolved.
* Click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Pulse.
* Click the Enable Pulse button (or "Update" if it's already partially configured).
* Check the box for Enable Pulse.
* (Note: Any "Enable alerts for Pulse" boxes would remain unchecked or be ignored, as the main Alert Policy itself is now disabled.)
* Click Save.
C. Resolve the Active Alert
* Navigate to the Alerts dashboard (click the "bell" icon in the top-left).
* Find the active alert: Pulse is not enabled.
* (Note: If the alert is not present, you would first go to the Health dashboard, run the check_pulse NCC check to generate it, and then return to the Alerts dashboard.)
* Select the checkbox next to the "Pulse is not enabled" alert.
* Click the Resolve button that appears at the top of the list. Since the underlying condition (Pulse being disabled) is now fixed, the alert will be successfully resolved.
NEW QUESTION # 26
The DB team is requesting an SQL database instance and has requested it be configured for best performance.
This VM has been migrated from a 3 tier solution into Nutanix.
The database VM hosts 4 databases, each set to a 20 GB limit. Logs are expected to not grow beyond 20 GB and should be limited to within 25% to avoid runaway processes. Do not configure more storage than is needed.
The VM that has been migrated is identified as sql3532. Once the VM has been properly reconfigured, the DBA team will reconfigure the OS and database.
The VM should be configured as per KB-3532.
While this VM is being tested, make sure it is the first VM to power up in the event the node it is on goes down.
To maximize performance, ensure as much of the VM as possible will be kept on SSD drives.
Note: The VM does not need to be powered on. The VM should remain on the default container and should not be configured with a volume group. No network is required at this time.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to reconfigure the sql3532 virtual machine.
This task is performed from the Prism Element interface for the cluster the VM is on (e.g., Cluster 1).
1. Locate and Update the VM
* From the Prism Element main dashboard, navigate to the VM view.
* Find the VM named sql3532 in the VM table.
* Select the checkbox next to sql3532 and click the Update button.
2. Configure HA Priority and Flash Mode
In the "Update VM" dialog, configure the HA and SSD performance settings:
* HA Priority:
* Find the VM High Availability section.
* Select the High Priority radio button. This ensures it is one of the first VMs to power on during an HA event.
* Flash Mode (SSD Performance):
* Scroll down to the Flash Mode section.
* Check the box to Enable Flash Mode. This pins the VM's vDisks to the SSD tier, satisfying the requirement to keep as much of the VM as possible on SSDs, especially since it's on the default (hybrid) container.
3. Reconfigure Disks (per KB-3532)
While still in the "Update VM" dialog, scroll to the Disks section to add the new data and log disks. The key to "best performance" (KB-3532) is to place Data and Logs on separate vSCSI controllers.
* (The VM already has an OS disk, which we will assume is on scsi.0.)
* Add Data Disk:
* Click the + Add New Disk button.
* Storage Container: default (as required).
* Size: 80 GB (for the 4 x 20 GB databases).
* Bus Type: SCSI.
* Device Index: 1. (This creates a new vSCSI controller, scsi.1, for the data disk).
* Click Add.
* Add Log Disk:
* Click the + Add New Disk button.
* Storage Container: default (as required).
* Size: 20 GB.
* Bus Type: SCSI.
* Device Index: 2. (This creates a third vSCSI controller, scsi.2, for the log disk).
* Click Add.
4. Save Configuration
* After adding the disks and setting HA/Flash Mode, click the main Save button at the bottom of the
"Update VM" dialog.
The VM is now configured with high availability, its storage is pinned to SSD, and its disk layout follows performance best practices by separating the OS, Data, and Log I/O paths onto three different controllers.
NEW QUESTION # 27
A company who offers Infrastructure as a Service needs to onboard a new customer. The new customer requires a dedicated cloud plan which tolerates two host failures.
The customer is planning to move current workloads in three waves, with three months between waves starting today:
* Wave One: 100 VMs
* Wave Two: 50 VMs
* Wave Three: 20 VMs
Workload profile is:
* vCPU: 4
* vRAM: 16 GB
* Storage: 200 GB
The service provider company needs to estimate required resources upfront, to accommodate customer requirements, considering also that:
* limit the number of total nodes
* selected system vendor HPE
* selected model DX365-10-G11-NVMe
* full-flash node (including NVMe + SSD)
* 12 months runway
Create and save the scenario as IaaS and export to the desktop, name the file IaaS-requirement.pdf Note: You must export the PDF to the desktop as IaaS-requirement.pdf to receive any credit.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to create and export the capacity planning scenario. This task is performed within Prism Central.
1. Navigate to the Planning Dashboard
* From the Prism Central main menu (hamburger icon), navigate to Operations > Planning.
2. Create and Define the Scenario
* Click the + Create Scenario button.
* In the dialog box:
* Scenario Name: IaaS
* Scenario Type: Select New Workload
* Click Create. This will open the scenario editor.
3. Configure Cluster and Runway Settings
* In the "IaaS" scenario editor, find the Runway setting (top left) and set it to 12 Months.
* Find the Cluster configuration tile and click Edit.
* Set Number of Host Failures to Tolerate to 2.
* Click Save.
4. Define the Workload Profile
* In the Workloads section, click the + Add Workload button.
* Select Create a new workload profile.
* Fill in the VM specifications:
* Workload Name: Customer-VM (or similar)
* vCPU per VM: 4
* Memory per VM: 16 GB
* Storage per VM: 200 GB
* Click Add.
5. Set the Workload Growth Plan (Waves)
* You will be returned to the main scenario editor. In the timeline section ("Workload Plan"), add the VMs:
* Wave One (Today):
* Click + Add under the "Today" column.
* Select the Customer-VM profile.
* Enter 100 VMs.
* Click Add.
* Wave Two (3 Months):
* Click the + icon on the timeline itself.
* Set the date to 3 Months from today.
* Click + Add under this new "3 Months" column.
* Select the Customer-VM profile.
* Enter 50 VMs.
* Click Add.
* Wave Three (6 Months):
* Click the + icon on the timeline.
* Set the date to 6 Months from today.
* Click + Add under this new "6 Months" column.
* Select the Customer-VM profile.
* Enter 20 VMs.
* Click Add.
6. Select the Hardware
* In the Hardware configuration tile, click Change Hardware.
* In the "Select Hardware" pane:
* Vendor: Select HPE.
* Model: Search for and select DX365-10-G11-NVMe.
* Note: This model is full-flash by definition, satisfying the requirement.
* Click Done. The planner will recalculate the required nodes.
7. Save and Export the Scenario
* Click the Save icon (floppy disk) in the top-right corner to save the IaaS scenario.
* Click the Export icon (arrow pointing down) in the top-right corner.
* Select PDF from the dropdown menu.
* A "Save As" dialog will appear.
* Navigate to the Desktop.
* Set the file name to IaaS-requirement.pdf.
* Click Save.
NEW QUESTION # 28
......
We continually improve the versions of our NCM-MCI-6.10 exam guide so as to make them suit all learners with different learning levels and conditions. The clients can use the APP/Online test engine of our NCM-MCI-6.10 exam guide in any electronic equipment such as the cellphones, laptops and tablet computers. Our after-sale service is very considerate and the clients can consult our online customer service about the price and functions of our NCM-MCI-6.10 Quiz materials. So our NCM-MCI-6.10 certification files are approximate to be perfect and will be a big pleasant surprise after the clients use them.
NCM-MCI-6.10 Test Collection Pdf: https://www.testpassed.com/NCM-MCI-6.10-still-valid-exam.html
DOWNLOAD the newest TestPassed NCM-MCI-6.10 PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1xhSgDIlRPB7A671syMjSthMxPJ1KJuHu