順便提一下,可以從雲存儲中下載KaoGuTi LEED-AP-BD-C考試題庫的完整版:https://drive.google.com/open?id=1LryppPCqpfCcv-78LzhtOhU3VbYXGdgA
現在很多IT專業人士都一致認為USGBC LEED-AP-BD-C 認證考試的證書就是登上IT行業頂峰的第一塊墊腳石。因此USGBC LEED-AP-BD-C認證考試是一個很多IT專業人士關注的考試。
| 主題 | 簡介 |
|---|---|
| 主題 1 |
|
| 主題 2 |
|
| 主題 3 |
|
| 主題 4 |
|
| 主題 5 |
|
| 主題 6 |
|
對於 USGBC的LEED-AP-BD-C考試認證每個考生都很迷茫。每個人都有自己不用的想法,不過總結的都是考試困難之類的,USGBC的LEED-AP-BD-C考試是比較難的一次考試認證,我相信大家都是耳目有染的,不過只要大家相信KaoGuTi,這一切將不是問題,KaoGuTi USGBC的LEED-AP-BD-C考試培訓資料是每個考生的必備品,它是我們KaoGuTi為考生們量身訂做的,有了它絕對100%通過考試認證,如果你不相信,你進我們網站看一看你就知道,看了嚇一跳,每天購買率是最高的,你也別錯過,趕緊加入購物車吧。
問題 #302
Which of the following activities must be prohibited within a building as a prerequisite to LEED certification?
答案:D
解題說明:
Smoking tobacco products must be prohibited within a building as a prerequisite to LEED certification, according to the Indoor Environmental Quality Prerequisite, Environmental Tobacco Smoke Control1. This prerequisite aims to prevent or minimize exposure of building occupants, indoor surfaces, and ventilation air distribution systems to environmental tobacco smoke (ETS), which is a known human carcinogen and a source of indoor air pollution2. The prerequisite requires the project to meet one of the following options:
* Option 1. No Smoking. Prohibit smoking in the building and within 25 feet (8 meters) of all entries, outdoor air intakes, and operable windows.
* Option 2. Smoking Areas. Designate smoking areas outside the building and at least 25 feet (8 meters) from all entries, outdoor air intakes, and operable windows. If smoking areas are enclosed, they must be negatively pressurized and vented directly to the outdoors. Prohibit smoking in all common areas of residential buildings and provide signage to indicate smoking and nonsmoking areas.
The other activities, such as burning fossil fuels, preparing non-organic foods, and manufacturing toxic chemicals, are not explicitly prohibited by any LEED prerequisites, although they may have negative impacts on the environment, health, and energy performance of the building.
問題 #303
Which one of the following represents quality transit service as defined in Location and Transportation Credit, Access to Quality Transit?
答案:B
解題說明:
The Location and Transportation Credit, Access to Quality Transit requires projects to locate within walking distance of existing or planned transit stops that provide access to quality transit service1. Quality transit service is defined as transit service that meets the minimum weekday and weekend headways (time between vehicles) and hours of operation listed in Table 1 of the credit requirements2. According to Table 1, the minimum weekday headway for bus service is 15 minutes, and the minimum weekday headway for rail service is 10 minutes. The minimum weekend headway for both bus and rail service is 30 minutes. The minimum hours of operation for both bus and rail service are 6 a.m. to 8 p.m. on weekdays and 8 a.m. to 6 p.m. on weekends2. In addition, the credit requires projects to locate within a 1/4 mi. (0.40 km) walking distance of bus, streetcar, or rideshare stops or within a 1/2 mi. (0.80 km) walking distance of bus rapid transit stops, light or heavy rail stations, commuter rail stations, or ferry terminals1.
Option A does not represent quality transit service because it only has two bus lines that may not meet the minimum headway and hours of operation requirements. Option C does not represent quality transit service because it is beyond the maximum walking distance of 1/2 mi. (0.80 km) for rail stations. Option D does not represent quality transit service because it is a private shuttle bus that does not qualify as a public transportation service, and it provides hourly service that does not meet the minimum headway requirements. Option B represents quality transit service because it has a rail station that is within the maximum walking distance of 1/2 mi. (0.80 km) from the project building, and it has one train line that operates Monday through Sunday, which implies that it meets the minimum headway and hours of operation requirements.
:
Access to Quality Transit
Access to Quality Transit - Canada Green Building Council
問題 #304
The results of a building energy model show that a building will consume 2,200,435 kilowatt-hours (kWh) per year (building is served solely by electricity). The building owner wants to achieve Energy and Atmosphere Credit, Green Power and Carbon Offsets. What is the minimum amount of green energy required to be purchased on an annual basis?
答案:B
解題說明:
LEED requires that at least 50% of a building's annual electricity consumption be offset by green power or carbon offsets to achieve the Energy and Atmosphere Credit: Green Power and Carbon Offsets. For this building with a projected annual consumption of 2,200,435 kWh, half of this amount, 1,100,218 kWh, must be purchased from green sources to meet the credit requirements. This strategy helps mitigate carbon emissions by promoting the use of renewable energy.
問題 #305
When preparing the Sustainable Sites Prerequisite, Construction Activity Pollution Prevention, the Construction General Permit must contain which of the following?
答案:C
解題說明:
The Construction General Permit (CGP) for the Sustainable Sites Prerequisite, Construction Activity Pollution Prevention, must contain an installation plan for perimeter control.This is part of the Erosion and Sedimentation Control (ESC) Plan, which is designed toprevent loss of soil during construction by stormwater runoff and/or wind erosion, prevent sedimentation of storm sewer or receiving streams, and prevent polluting the air with dust and particulate matter1.
:
Sustainable Sites Prerequisites | GlobalSpec
問題 #306
Which of the following strategies will aid in reducing indoor water use?
答案:B
解題說明:
According to theLEED V5: Building Design + Construction Guide, one of the strategies to reduce indoor water use is to optimize the consumption of showerheads by selecting fixtures that have a flow rate lower than the baseline of 2.0 gallons per minute (gpm) at 80 psi, or a local equivalent for projects outside the U.S.This can help the project achieve the Water Efficiency Prerequisite, Indoor Water Use Reduction, and the Water Efficiency Credit, Indoor Water Use Reduction, by reducing the aggregate water consumption from plumbing fixtures and fittings by at least 20% from the baseline1.
The other choices are not strategies to reduce indoor water use, because:
Designing drip irrigation for landscape is a strategy to reduce outdoor wateruse, not indoor water use1.
Using high-efficiency HVAC systems is a strategy to reduce energy use, not water use, although it may have some indirect water savings by reducing the cooling tower water use2.
Excluding janitor closets in the building is not a feasible or practical strategy, as janitor closets are necessary for cleaning and maintenance purposes, and may also be required by codes or standards3.
:LEED V5: Building Design + Construction Guide, Water Efficiency Prerequisite, Indoor Water Use Reduction, Requirements1;LEED V5: Building Design + Construction Guide, Water Efficiency Credit, Indoor Water Use Reduction, Requirements1;LEED V5: Building Design + Construction Guide, Energy and Atmosphere Credit, Optimize Energy Performance, Requirements2;LEED V5: Building Design + Construction Guide, Indoor Environmental Quality Credit, Green Cleaning - High-Performance Cleaning Program, Requirements3
問題 #307
......
KaoGuTi提供給你最權威全面的LEED-AP-BD-C考試考古題,命中率極高,考試中會出現的問題可能都包含在這些考古題裏了,我們也會隨著大綱的變化隨時更新考古題。它可以避免你為考試浪費過多的時間和精力,助你輕鬆高效的通過考試。即便您沒有通過考試,我們也將承諾全額退款!所以你將沒有任何損失。機會是留給有準備的人的,希望你不要錯失良機。
LEED-AP-BD-C最新考古題: https://www.kaoguti.com/LEED-AP-BD-C_exam-pdf.html
2026 KaoGuTi最新的LEED-AP-BD-C PDF版考試題庫和LEED-AP-BD-C考試問題和答案免費分享:https://drive.google.com/open?id=1LryppPCqpfCcv-78LzhtOhU3VbYXGdgA