The Tech in Surgery - Certified (NCCT), TS-C (NCCT) (TS-C) is available in three easy-to-use forms. The first one is TS-C dumps PDF format. It is printable and portable. You can print TS-C questions PDF or access them via your smartphones, tablets, and laptops. The PDF format can be used anywhere and is essential for students who like to learn on the go.
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Preoperative Care and Preparation | 32% | - Sterile Technique
|
| Topic 2: Intraoperative Care and Preparation | 24.7% | - Surgeon Support
|
| Topic 3: End of Procedure Tasks and Postoperative Care | 16% | - End of Procedure Tasks
|
| Topic 4: Perioperative Care and Preparation | 27.3% | - Communication and Reporting
|
>> New Braindumps TS-C Book <<
As we know, our products can be recognized as the most helpful and the greatest NCCT TS-C test engine across the globe. Even though you are happy to hear this good news, you may think our price is higher than others. We can guarantee that we will keep the most appropriate price because we want to expand our reputation of NCCT TS-C Preparation test in this line and create a global brand about the products.
NEW QUESTION # 164
When preparing a patient for a total hip replacement, how should pressure pads be placed?
Answer: B
Explanation:
An axillary roll is an appropriate positioning device for a patient undergoing total hip arthroplasty when the procedure is performed in the lateral decubitus position.
During many posterior-approach total hip replacements, the patient is positioned on the nonoperative side to provide access to the affected hip. This position places pressure on the dependent shoulder, thorax, and upper extremity, creating a potential risk of brachial plexus compression and impaired circulation.
The axillary roll is positioned beneath the dependent thorax, just distal to the axillary fold, rather than directly within the axilla. Its purpose is to reduce pressure on the neurovascular structures and help protect the brachial plexus.
STERIS positioning guidance recommends placing the roll at approximately the seventh to ninth rib level and verifying bilateral radial pulses after positioning.
steris.com
Option B is incorrect because placing a pillow under both knees does not address the principal pressure risks associated with lateral hip positioning.
Option C is incorrect because a kidney rest is associated with selected lateral kidney procedures rather than routine total hip arthroplasty.
Option D is incorrect because bilateral chest rolls are more characteristic of selected prone-positioning techniques.
Additional padding should protect the dependent ear, shoulder, hip, knees, and ankles while maintaining neutral spinal alignment.
References: NCCT TS-C Detailed Test Plan - Preoperative Care and Preparation; Section 2B, Patient Safety; Surgical Positioning; Orthopedic Procedures.
Supporting references: STERIS - The Ultimate Guide to the Lateral Position ; Surgical Approaches for Total Hip Arthroplasty .
Clinical qualification: The question assumes lateral positioning. Some total hip arthroplasties use a supine anterior approach, for which an axillary roll is not routinely required.
NEW QUESTION # 165
Which of the following is the MOST common scope used during genitourinary surgery?
Answer: B
Explanation:
The cystoscope is one of the most commonly used endoscopic instruments in genitourinary surgery because it permits direct visualization of the urethra, urinary bladder, and associated anatomical structures.
Cystoscopy is performed for diagnostic and therapeutic purposes, including evaluation of hematuria, bladder tumors, urethral abnormalities, urinary obstruction, and recurrent urinary tract conditions.
Cystoscopes are available in rigid and flexible configurations. Rigid cystoscopes commonly consist of a telescope, sheath, obturator, bridge, and irrigation components. Flexible cystoscopes provide greater maneuverability and are frequently used during outpatient diagnostic procedures.
The NCBI Bookshelf identifies cystourethroscopy as one of the most frequently performed procedures in urologic practice.
NCBI
Option A is incorrect because a surgical microscope provides magnification during selected procedures but is not a genitourinary endoscope.
Option B is incorrect as the best answer because laparoscopes are used for minimally invasive abdominal and pelvic procedures across several specialties.
Option D is incorrect because an arthroscope is designed for visualization and treatment of joint structures.
The surgical technologist must ensure that the appropriate cystoscope, light source, camera, irrigation equipment, and specialized accessories are available and functioning correctly.
References:
NCCT TS-C Detailed Test Plan - Intraoperative Care and Preparation; Surgical Instrumentation; Endoscopic Equipment; Genitourinary Procedures.
NCBI Bookshelf - Cystoscopy .
Urologic Surgery - Endoscopic Instrumentation and Equipment .
NEW QUESTION # 166
Intraoperatively, the surgeon asks the surgical technologist to assist with hemostasis of a bleeding vessel near the median nerve. Which of the following should the surgical technologist anticipate passing to the surgeon?
Answer: A
Explanation:
Bipolar forceps and atraumatic forceps without teeth are the most appropriate instruments for controlled hemostasis near the median nerve.
The median nerve supplies motor and sensory innervation to important structures of the forearm and hand.
Injury can produce sensory loss, weakness, impaired thumb opposition, and functional disability.
Bipolar electrosurgery delivers electrical current between two closely positioned electrode tips. This confines the current pathway primarily to tissue held between the forceps, allowing relatively localized coagulation.
Compared with monopolar electrosurgery, bipolar instrumentation provides greater control when operating near delicate nerves and vascular structures. AORN identifies bipolar energy as particularly useful in procedures involving delicate tissues.
Aorn.org
Option A is less appropriate because a conventional monopolar electrosurgical pencil produces a broader current pathway.
Option B is incorrect because toothed forceps may traumatize delicate neural or vascular tissues, while monopolar electrosurgery presents additional thermal risk.
Option D includes the appropriate bipolar device but combines it with toothed forceps rather than the preferred atraumatic tissue-handling instrument.
The surgical technologist must anticipate precision instruments, appropriate electrosurgical settings, and irrigation when required.
Bipolar electrosurgery can still cause thermal injury. Published research emphasizes careful electrode positioning and irrigation when coagulating close to neural structures.
PubMed
References:
NCCT TS-C Detailed Test Plan - Intraoperative Care and Preparation; Section 3B1, Instrument Selection; Section 3B4, Electrosurgical Assistance.
AORN - The Electrosurgical Unit .
Prevention of Nerve Root Thermal Injury Caused by Bipolar Cauterization .
NEW QUESTION # 167
The sterility of the Mayo stand is breached after a carotid procedure is complete while the patient is still intubated. The surgical technologist should do which of the following?
Answer: D
Explanation:
When the sterility of the Mayo stand is compromised while the patient remains intubated in the operating room, the surgical technologist must remove the contaminated setup from use and establish a replacement sterile instrument arrangement.
The Association of Surgical Technologists (AST) explicitly requires the Mayo stand to remain sterile until the patient has been transported out of the operating room. This precaution ensures the immediate availability of surgical instruments if unexpected complications require emergency intervention.
ast.org
Following carotid surgery, complications may include postoperative hemorrhage, expanding cervical hematoma, and airway compromise. A rapidly expanding neck hematoma can compress the airway and necessitate emergency wound reopening or surgical exploration.
PubMed
Option A is correct because contaminated instruments and surfaces must be replaced with sterile substitutes to restore emergency surgical readiness.
Option B is incorrect because ignoring the compromised stand leaves the surgical team without an immediately available sterile instrument setup.
Option C is incorrect because instruments cannot be resterilized immediately on the existing stand, and the patient should not be unnecessarily exposed to delays.
Option D is incorrect because covering a contaminated area with another sterile drape does not reliably restore sterile integrity.
Replacement instruments, including hemostats, scissors, retractors, and a needle holder, should remain available until patient transfer.
References:
NCCT TS-C Detailed Test Plan - End of Procedure Tasks and Postoperative Care, Section 4B1: Maintaining Sterility of the Back Table and Mayo Stand.
AST - Position Statement on the Back Table and Mayo Stand Remaining Sterile Until Patient Transport .
Neck Haematoma After Carotid Endarterectomy: Risks, Rescue, and Prevention .
NEW QUESTION # 168
The surgical hand scrub is intended to remove which of the following microorganisms from the skin?
Answer: C
Explanation:
The principal objective of surgical hand antisepsis is to eliminate transient microorganisms and substantially reduce resident microbial flora on the hands and forearms before sterile gowning and gloving.
Transient microorganisms are organisms acquired through contact with patients, contaminated objects, environmental surfaces, and other external sources. They predominantly occupy superficial skin layers and are more readily removed through appropriate handwashing and antiseptic preparation.
Option C is correct because transient microorganisms are the population most directly targeted for removal during surgical hand preparation.
Option B is incorrect as the best single answer because resident flora colonize deeper structures, including hair follicles and sebaceous glands. Surgical antisepsis reduces their numbers but does not completely eliminate them.
Option D is incorrect because indigenous microorganisms generally represent normal resident skin flora.
Option A is incorrect because opportunistic describes a microorganism ' s capacity to cause infection under favorable conditions, rather than its classification according to duration of skin colonization.
The World Health Organization distinguishes the two principal objectives of surgical hand preparation:
removal of transient flora and substantial reduction of resident flora.
NCBI
Maintaining antimicrobial activity throughout surgery is important because microorganisms remaining beneath surgical gloves may contribute to contamination if gloves become perforated.
Reference Topics: NCCT TS-C Detailed Test Plan - Preoperative Care and Preparation, Section 2C2:
Surgical Hand Scrub Sequence; Aseptic Technique; Microbiology; Infection Prevention.
NEW QUESTION # 169
......
No matter the worker generation or students, they are busy in dealing with other affairs, so spending much time on a TS-C exam may make a disturb between their work and life. However if you buy our TS-C exam engine, you just only need to spend 20-30 hours to practice training material and then you can feel secure to participate in this exam. We can make sure the short time on TS-C training engine is enough for you to achieve the most outstanding result.
Reliable TS-C Exam Testking: https://www.crampdf.com/TS-C-exam-prep-dumps.html