記録に便利なように原稿に印刷されたInternational Code CouncilのM2試験問題をすばやく学習したい場合は、M2ガイドトレントの模擬模擬テストを選択できます。 JPTestKing学習効果をタイムテストし、M2学習クイズでソフトウェアモデルを提供します。実際のテスト環境で問題と速度を解決する能力を発揮するのに役立ちます。 最後に、他の電子機器で練習したい場合は、オンライン版を使用してM2練習資料を選択できます。
| Section | Objectives |
|---|---|
| Topic 1: Materials and Specifications | - Approved Materials
|
| Topic 2: General Administration | - Code Scope and Administration
|
| Topic 3: Heating and Cooling Systems | - Cooling Systems
|
| Topic 4: Combustion Air and Fuel Supply | - Combustion Air
|
| Topic 5: Hydronic Piping and Refrigeration | - Hydronic Systems
|
| Topic 6: Chimneys and Vents | - Vent Systems
|
| Topic 7: Duct Systems | - Air Distribution
|
| Topic 8: Ventilation and Exhaust Systems | - Ventilation
|
JPTestKingのM2には何か品質問題があることを見つければ、あるいは試験に合格しなかったのなら、弊社が無条件で全額返金することを約束します。JPTestKingは専門的にInternational Code CouncilのM2試験の最新問題と解答を提供するサイトで、M2についての知識をほとんどカバーしています。
質問 # 18
An 8-inch Type B venting system with a listed vent cap must terminate a minimum of _____ feet above the flat roof through which it passes.
正解:C
解説:
For a Type B gas vent with a listed vent cap terminating through a flat roof , the minimum required termination height is 1 foot above the roof . That makes Option A correct. This is consistent with gas vent termination tables used with listed Type B vent systems and the code framework for Type B vent terminations.
質問 # 19
Given: a six-story, sprinklered, multifamily building with a continuously ventilated shaft extending vertically from the first floor to the roof and used for exhaust.
Which of the following requirements must also be met?
正解:B
解説:
For this type of continuously ventilated exhaust shaft serving a multifamily building, the code requires the kitchen exhaust connection to penetrate the shaft and extend vertically not less than 22 inches without a fire damper. That matches Option D .
質問 # 20
Which of the following is not a required mechanical inspection?
正解:C
解説:
The ICC mechanical administrative inspection sequence includes underground inspection , rough-in inspection , and final inspection as required inspections. An annual system test is not listed as one of the required permit inspections in that section, so Option D is the correct answer. This fits the M2 General Administration content area, which includes permit and inspection administration.
質問 # 21
To test for tightness, a consumer's gas piping should never be filled with:
正解:C
解説:
The IFGC section on test medium states that the test medium shall be air, nitrogen, carbon dioxide or an inert gas , and specifically states that oxygen shall not be used as a test medium . That makes C the correct answer.
質問 # 22
Given: Fabricated of type 430 stainless steel.

Optional type _____ stainless steel is available.
正解:B
解説:
Based on the specification sheet shown in the exhibit, the hood is fabricated of Type 430 stainless steel , and the optional stainless steel listed is Type 304 . Therefore, the correct answer is C .
質問 # 23
......
あなたの目標はとても高いですから、あなたに色々なヘルプをあげられる資料が必要です。JPTestKing International Code CouncilのM2試験問題集はあなたが自分の目標を達成することを助けられます。JPTestKing International Code CouncilのM2問題資料は高度に認証されたIT領域の専門家の経験と創造を含めているものです。当社の製品は、すべての可能性のある問題を試させられます。受験生の皆様に問題の100パーセント真実な解答を提供することを保証します。
M2資料勉強: https://www.jptestking.com/M2-exam.html