無料でクラウドストレージから最新のPass4Test COH-285 PDFダンプをダウンロードする:https://drive.google.com/open?id=1QVI-CLyZ01OZ7PrdaNvQhVbSoVdnxYFa
実際のCOH-285試験では常に緊張しており、実際の試験に適応するのは難しいと感じていますか? 「はい」と答えた場合、COH-285試験クイズのソフトウェアバージョンを使用してみてください。 ソフトウェアバージョンは実際のテスト環境をシミュレートできるため、COH-285試験ガイドのソフトウェアバージョンが最適です。ソフトウェアバージョンごとにCOH-285試験の雰囲気を事前に感じることができます。
| Certification Vendor: | Cohesity |
|---|---|
| Exam Name: | COH-285 – Cohesity Certified Protection Professional – NetBackup Appliances |
| Exam Number: | COH-285 |
| Available Languages: | English |
| Related Certifications: | Cohesity Certified Protection Professional – NetBackup |
| Exam Format: | Multiple choice (single-select), Multiple select |
| Passing Score: | 65% |
| Certificate Validity Period: | 2 years |
| Exam Duration: | 105 minutes |
| Exam Price: | $200 USD |
| Recommended Training: | Cohesity Academy Training Resources |
| Exam Registration: | Official Cohesity Certification Registration |
| Sample Questions: | Cohesity COH-285 Sample Questions |
| Exam Way: | Online proctored exam (third-party delivery platform) |
| Pre Condition: | None |
| Official Syllabus URL: | https://www.cohesity.com/academy/certification/exam-vcs-285/ |
別の人の言い回しより自分の体験感じは大切なことです。我々の希望は誠意と専業化を感じられることですなので、お客様に無料のCohesity COH-285問題集デモを提供します。購買の後、行き届いたアフタサービスを続けて提供します。Cohesity COH-285問題集を更新しるなり、あなたのメールボックスに送付します。あなたは一年間での更新サービスを楽しみにします。
| トピック | 出題範囲 |
|---|---|
| トピック 1 |
|
| トピック 2 |
|
| トピック 3 |
|
| トピック 4 |
|
質問 # 158
A NetBackup restore job is failing with the message "Unable to find backup file". What could be the cause of this error?
正解:B
質問 # 159
Which guide should be consulted to learn about the function and configuration of cloud storage in NetBackup?
正解:D
質問 # 160
An administrator runs the following command on the primary server to test connectivity to a client:
bptestbpcd -client clientA
The administrator receives the following message:
< 16 > bptestbpcd main: Function ConnectToBPCD (clientA) failed: 25 cannot connect on socket Which two reasons may cause this error message? (Select two.)
正解:C、E
解説:
The correct causes are an incorrect client host-name resolution entry on the primary server and stopped NetBackup client processes. The bptestbpcd utility is specifically used to establish a connection from a NetBackup server to the bpcd daemon on a NetBackup host or client, and successful output reports the socket connections that were established. A status 25: cannot connect on socket means the primary server could not complete that socket connection. Official NetBackup troubleshooting guidance states that status 25 commonly results when the client does not acknowledge the TCP connection, the server cannot resolve the client, the client is not listening on bpcd/vnetd, or name resolution fails. Therefore, an incorrect hosts-file entry for clientA on the primary server can send the connection attempt to the wrong address or prevent proper resolution. Likewise, if the NetBackup processes on the client are stopped, the client will not be listening on the required bpcd/vnetd ports. The troubleshooting procedure specifically instructs administrators to verify that the client has bpcd and vnetd ports in listening mode. Options B and E are unrelated to this client-side connection test, while C aligns more closely with authorization failures such as status 59. References/topics:
bptestbpcd, status code 25, client name resolution, and bpcd/vnetd client connectivity troubleshooting.
質問 # 161
After creating a NBU-Catalog type backup policy, an administrator receives the following message:
"DR file is on the same partition as your catalog and will be unusable in an actual disaster or disk failure." Which two options are available to the administrator to ensure the DR file is available for future use? (Select two.)
正解:C、D
解説:
The correct options are A and E. The warning indicates that the catalog disaster recovery file is being written to a location that would likely be lost with the NetBackup catalog during a disk or server failure. Cohesity NetBackup documentation for the NBU-Catalog policy's Disaster Recovery tab states that the DR path is where disaster recovery information is saved, and explicitly recommends not saving that information to the local computer; instead, it should be saved to a network share or removable device. It also states that, on UNIX, the path cannot be on the same partition as /usr/openv/netbackup; it must be changed to a directory on a different partition. Therefore, placing the DR file on a volume other than the NetBackup volume resolves the warning. Cohesity also documents the Send disaster recovery email option, where one or more administrator email addresses can be entered so NetBackup sends DR information after every catalog backup.
The disaster recovery email includes recovery instructions and the image file/package attachments needed for catalog recovery. References/topics: NBU-Catalog policy, Disaster Recovery tab, DR file path, and disaster recovery email configuration.
質問 # 162
How can you manually duplicate a backup image?
正解:B
質問 # 163
......
COH-285日本語認定: https://www.pass4test.jp/COH-285.html
ちなみに、Pass4Test COH-285の一部をクラウドストレージからダウンロードできます:https://drive.google.com/open?id=1QVI-CLyZ01OZ7PrdaNvQhVbSoVdnxYFa