NETA NETA_2 Exam Syllabus Topics:

SectionWeightObjectives
Component Testing20-25%- Switchgear Testing
  • 1. Dielectric Withstand Tests
  • 2. Contact Resistance Tests
  • 3. Circuit Breaker Timing Tests
- Transformers Testing
  • 1. Excitation Current Tests
  • 2. Winding Resistance Tests
  • 3. Turns Ratio Tests
- Protective Devices Testing
  • 1. Overcurrent Relay Tests
  • 2. Coordination Studies
- Conductors and Cables Testing
  • 1. Insulation Resistance Tests
  • 2. Hi-Pot Tests
  • 3. Continuity Tests
Electrical Theory and Fundamentals15-20%- Electrical Safety Principles
  • 1. Personal Protective Equipment
  • 2. Lockout/Tagout Procedures
  • 3. Arc Flash Safety
- AC/DC Circuit Analysis
  • 1. Ohm's Law and Power Calculations
  • 2. Series and Parallel Circuits
  • 3. Kirchhoff's Laws
  • 4. Three-Phase Systems
Testing Equipment and Instrumentation20-25%- Relay Testing Equipment
  • 1. Protective Relay Testers
- Voltmeters and Ammeters
  • 1. Digital Multimeters
  • 2. Clamp Meters
- Circuit Breaker Testers
  • 1. Secondary Injection Test Sets
  • 2. Primary Injection Test Sets
- Grounding and Bonding Testers
  • 1. Earth Resistance Testers
  • 2. Ground Bond Testers
- Insulation Testing Equipment
  • 1. Hipot Testers
  • 2. Insulation Resistance Analyzers
  • 3. Megohmmeters
Documentation and Reporting10-15%- Test Documentation
  • 1. Data Recording Procedures
  • 2. Test Results Interpretation
- Reports and Certification
  • 1. NRTL Certification Requirements
  • 2. Test Report Writing
Testing Procedures and Standards25-30%- IEEE Testing Standards
  • 1. IEEE 62.45 Low-Voltage Testing
  • 2. IEEE 4 High-Voltage Testing
- NETA Maintenance Testing Specifications
  • 1. Visual Inspection Procedures
  • 2. Acceptance Testing Standards
  • 3. Electrical Testing Procedures
- NFPA 70E Electrical Safety
  • 1. energized Work Permits
  • 2. Arc Flash Hazard Analysis

>> NETA_2試験情報 <<

NETA_2復習問題集 & NETA_2実際試験

確かにNETA NETA_2試験に準備する過程は苦しいんですけど、NETA NETA_2資格認定を手に入れるなり、IT業界で仕事のより広い将来性を持っています。あなたの努力を無駄にするのは我々GoShikenのすべきことです。GoShikenのレビューから見ると、弊社GoShikenは提供している質高い試験資料は大勢の顧客様の認可を受け取ったと考えられます。我々はあなたにNETA NETA_2試験に合格させるために、全力を尽くします。

NETA Level 2 Certified Assistant Electrical Testing Specialist 認定 NETA_2 試験問題 (Q70-Q75):

質問 # 70
OSHA requires testing of a voltmeterafterverifying absence of voltage when testing circuits above what voltage level?

正解:D

解説:
A core safety practice in electrical testing is verifying that your voltage tester is functioning properlyboth before and afterperforming a test for absence of voltage. This practice is commonly summarized as"live- dead-live": test the meter on a known live source, test the circuit (dead check), then re-test on a known live source to ensure the meter didn't fail during the process.
Within OSHA-related electrical safety expectations and common field practice aligned with NETA work, this verification is emphasized especially in higher-voltage contexts, and the flash-card target here isabove 600 V.
Above this threshold, the consequences of a false "dead" reading are severe, and verification of instrument operation becomes non-negotiable.
NETA Level 2 technicians must demonstrate disciplined instrument verification habits. Even if a meter reads zero, it must be proven functional immediately afterward. This prevents relying on a meter with a blown fuse, dead battery, damaged leads, or internal failure-each of which could incorrectly indicate "no voltage" on an energized system.


質問 # 71
A transformer contains insulating fluid with aspecific gravity greater than 1. From where should the oil sample be drawn?

正解:C

解説:
Specific gravity greater than 1 means the insulating fluid isheavier than water. Any free water contamination will settlebelowthe oil. To avoid collecting settled contaminants and to obtain a representative oil sample, NETA practice requires sampling from thetop of the tank.
Correct sampling technique is critical for accurate dielectric, moisture, and dissolved gas analysis results.
NETA Level 2 technicians must understand fluid properties to avoid misleading test conclusions.


質問 # 72
Arc-flash incident energy is expressed in:

正解:B

解説:
Incident energy quantifies thermal exposure from an arc flash and is expressed incal/cm². This value is used to determine PPE requirements and safe work practices.


質問 # 73
When reinstalling a draw-out circuit breaker into a metal-clad switchgear cubicle, in what condition must the breaker be?

正解:A

解説:
For safety and mechanical integrity, circuit breakers must beopen and racked outbefore installation or removal from cubicles. NETA Level 2 technicians must follow correct breaker handling procedures to prevent arc flash, equipment damage, and mechanical interlock failures during commissioning and maintenance.


質問 # 74
When making a resistance measurement, which ohmmeter range should be selectedinitially?

正解:A

解説:
Starting with thelowest resistance rangeprovides maximum sensitivity and allows the technician to determine whether resistance is within the expected low-ohmic range. This approach supports accurate measurements during continuity testing, bolted-connection checks, and component verification.


質問 # 75
......

安全で信頼できるウェブサイトとして、あなたの個人情報の隠しとお支払いの安全性を保障していますから、弊社のNETAのNETA_2試験ソフトを安心にお買いください。弊社のGoShikenは最大なるIT試験のための資料庫ですので、ほかの試験に興味があるなら、GoShikenで探したり、弊社の係員に問い合わせたりすることができます。心よりご成功を祈ります。

NETA_2復習問題集: https://www.goshiken.com/NETA/NETA_2-mondaishu.html

BONUS!!! GoShiken NETA_2ダンプの一部を無料でダウンロード:https://drive.google.com/open?id=1JCgnEO8WSxfACoQ6Wl6GFRj5RnG3R40o