P.S. Free & New LEED-AP-BD-C dumps are available on Google Drive shared by PracticeTorrent: https://drive.google.com/open?id=1XJYHkKeGFgBkSEtQx9PjoW0aCH3Lo7Ci
The LEED-AP-BD-C study guide provided by the PracticeTorrent is available, affordable, updated and of best quality to help you overcome difficulties in the actual test. We continue to update our dumps in accord with LEED-AP-BD-C real exam by checking the updated information every day. The contents of LEED-AP-BD-C Free Download Pdf will cover the 99% important points in your actual test. In case you fail on the first try of your exam with our LEED-AP-BD-C free practice torrent, we will give you a full refund on your purchase.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
| Topic 7 |
|
| Topic 8 |
|
>> Valid LEED-AP-BD-C Test Questions <<
Discount is being provided to the customer for the entire USGBC LEED-AP-BD-C preparation suite. These LEED-AP-BD-C learning materials include the LEED-AP-BD-C preparation software & PDF files containing sample Interconnecting USGBC LEED-AP-BD-C and answers along with the free 90 days updates and support services. We are facilitating the customers for the USGBC LEED-AP-BD-C preparation with the advanced preparatory tools.
NEW QUESTION # 181
Which of the following are control measures recommended by the Sheet Metal and Air Conditioning National Contractors Association (SMACNA) for the Indoor Environmental Quality Credit, Construction Indoor Air Quality Management Plan?
Answer: B
Explanation:
Source control is one of the control measures recommended by the Sheet Metal and Air Conditioning National Contractors Association (SMACNA) for the Indoor Environmental Quality Credit, Construction Indoor Air Quality Management Plan. Source control means minimizing the generation and emission of indoor air pollutants from the construction activities and materials. Some examples of source control are1:
*Using low-emitting adhesives, sealants, paints, coatings, and flooring systems that comply with the VOC limits of the applicable LEED credit.
*Storing absorptive materials in a protected area and covering them with plastic sheeting to prevent moisture and mold growth.
*Scheduling the installation of finish materials after the completion of wet and dusty work, such as concrete pouring, drywall sanding, and painting.
*Isolating work areas where high levels of contaminants are generated or used, such as welding, cutting, grinding, and solvent cleaning, and providing adequate ventilation and exhaust.
*Prohibiting smoking, eating, and drinking in the work areas, and providing designated areas for these activities.
References:
*Construction indoor air quality management plan | U.S. Green Building Council1
NEW QUESTION # 182
Which of the following strategies would be considered an acceptable minor improvement within the wetland buffer for Location and Transportation Credit, Sensitive Land Protection?
Answer: B
Explanation:
Explanation
Providing a vehicular access drive that is less than 16 ft. (5 m) in width is considered an acceptable minor improvement within the wetland buffer for Location and Transportation Credit, Sensitive Land Protection.This credit requires avoiding development on land that meets one or more of the following criteria: prime farmland, floodplains, threatened or endangered species habitat, water bodies, wetlands, or land within 100 feet (30 meters) of these water bodies or wetlands1.However, the credit allows minor improvements within the wetland buffer if they are necessary for the project and have minimal environmental impact2.Examples of minor improvements include trails, boardwalks, stormwater outfalls, and utility crossings2.References:
* Credit: Sensitive land protection | U.S. Green Building Council
* NC-v4.1 LTc2: Sensitive land protection | LEEDuser
NEW QUESTION # 183
Massing and orientation in Integrative Process Credit. Integrative Process evaluates how rotating the building 90 degrees affects
Answer: C
Explanation:
Massing and orientation are important factors that affect the energy performance of a building. Massing refers to the shape and size of the building, and orientation refers to the direction that the building faces. By rotating the building 90 degrees, the project team can evaluate how the change in orientation affects the energy loads of the building, such as heating, cooling, and lighting. For example, a building that faces south may receive more solar heat gain and daylight than a building that faces north, which may reduce the need for artificial lighting and heating, but increase the need for cooling and shading. The project team can use the results of the analysis to optimize the massing and orientation of the building to achieve the best energy performance.
Reference:
LEED v4 Reference Guide for Building Design and Construction, Integrative Process Credit: Integrative Process, page 811 Integrative Process Worksheet2
NEW QUESTION # 184
A rectangular office building is located in an extremely humid climate and is shaded by very large adjacent buildings on all four sides. If the building owner wants to decrease the annual energy cost for operating the building, which of the following would be the best design approach?
Answer: D
Explanation:
The best design approach for the office building is D. Recover waste energy through exhaust air energy recovery systems. This is because:
Installing glazing with a higher solar heat gain factor would increase the cooling load and energy consumption of the building, especially in an extremely humid climate where heat gain is high1.
Installing photovoltaic panels on the sides of the building would generate electricity from solar radiation, but it would not reduce the cooling load or energy consumption of the building, unless the electricity is used to power a heat pump or other cooling device2.
Increasing outdoor air intake quantities during summer months would provide more fresh air to dilute the indoor pollutants and improve the indoor air quality, but it would not reduce the cooling load or energy consumption of the building, unless it is combined with a ventilation system that recovers waste energy from the exhaust air stream34.
An exhaust air energy recovery system (ERV) is a type of mechanical ventilation that uses a heat exchanger to transfer heat between two streams of air: one that enters the building and one that exits. The ERV pre-cools and dehumidifies the incoming ventilation air by sending the rejected heat into the exhaust airstream to cool the condenser coil at a lower temperature. This reduces both the cooling load and energy consumption of the building, as well as improving its indoor humidity levels34. An ERV can also provide some fresh outdoor air to meet ASHRAE Standard 62 ventilation rates5.
Therefore, an ERV is a more efficient and effective design approach than glazing, photovoltaic panels, or increased outdoor air intake quantities for reducing the annual energy cost for operating an office building in an extremely humid climate and shaded by very large adjacent buildings on all four sides.
NEW QUESTION # 185
A Photovoltaic (PV) system was installed on a 35,000 ft2 (3 252 m2) project. What actions need to take place in order to meet compliance for Energy and Atmosphere Prerequisite, Fundamental Commissioning (Cx) and Verification?
Answer: B
Explanation:
The correct answer is C, the Cx agent for the project must conduct or oversee the Cx of the PV system. According to theLEED V5Reference Guide for Building Design and Construction, the Energy and Atmosphere Prerequisite, Fundamental Commissioning and Verification, requires that all energy-related systems, including renewable energy systems such as PV, be commissioned by an independent commissioning agent (CxA) or a qualified member of the project team who reports to the owner.The CxA or the qualified team member must perform or oversee all commissioning activities, including developing a commissioning plan, reviewing design documents and submittals, verifying installation and performance, and preparing a commissioning report12References:1:LEED V5Reference Guide for Building Design and Construction, Energy and Atmosphere Prerequisite: Fundamental Commissioning and Verification, page 562.2:LEED V5Reference Guide for Building Design and Construction, Glossary, page 1020.
NEW QUESTION # 186
......
One of the best features of USGBC LEED-AP-BD-C exam dumps is its discounted price. Our USGBC LEED-AP-BD-C Exams prices are entirely affordable for everyone. We guarantee you that no one can beat us in terms of LEED-AP-BD-C Exam Dumps prices. Get any USGBC LEED-AP-BD-C exam dumps format and start preparation with confidence.
Latest Test LEED-AP-BD-C Simulations: https://www.practicetorrent.com/LEED-AP-BD-C-practice-exam-torrent.html
P.S. Free & New LEED-AP-BD-C dumps are available on Google Drive shared by PracticeTorrent: https://drive.google.com/open?id=1XJYHkKeGFgBkSEtQx9PjoW0aCH3Lo7Ci