International Code Councilの93-Tall-Mass-Timber-Buildings試験準備は、テストヒット率が高いため、98%〜100%の合格率です。 したがって、当社の93-Tall-Mass-Timber-Buildings学習教材は効果的であるだけでなく、有用でもあります。 誰もが知っているように、時間は誰にとっても非常に重要です。 一部の候補者は、自分の仕事や家族で非常に忙しいです。 93-Tall-Mass-Timber-Buildings試験の審査に時間をかけることは非常に困難です。 ただし、93-Tall-Mass-Timber-Buildings試験の教材を使用する場合、学習する時間はほとんどなく、93-Tall-Mass-Timber-Buildings合格率は高くなります。 93-Tall-Mass-Timber-Buildings学習教材はあなたの信頼に値します。
| Section | Objectives |
|---|---|
| Topic 1: Code Compliance and Related Requirements | - Sound transmission requirements - Energy code requirements applicable to mass timber buildings - Documentation and verification of compliance |
| Topic 2: Special Inspection Requirements | - Inspection of connections and protective materials - Inspector duties and responsibilities - Special inspection procedures for tall mass timber buildings |
| Topic 3: Tall Mass Timber Building Code Provisions | - Types IV-A, IV-B and IV-C construction - International Building Code requirements for tall mass timber construction - Mass timber materials and construction requirements |
| Topic 4: Construction Fire Safety | - Construction-phase fire safety requirements - International Fire Code requirements - Protection of mass timber during construction |
| Topic 5: Fire Protection and Fire-Resistance | - Fire protection systems and related provisions - Fire-resistance requirements - Noncombustible protection and protection of mass timber elements |
| Topic 6: Structural Inspection | - Connections and fastening systems - Mass timber structural elements - Structural loads and related code requirements |
>> 93-Tall-Mass-Timber-Buildingsウェブトレーニング <<
弊社のInternational Code Council 93-Tall-Mass-Timber-Buildings問題集を使用した後、93-Tall-Mass-Timber-Buildings試験に合格するのはあまりに難しくないことだと知られます。我々Fast2test提供する93-Tall-Mass-Timber-Buildings問題集を通して、試験に迅速的にパースする技をファンドできます。あなたのご遠慮なく購買するために、弊社は提供する無料のInternational Code Council 93-Tall-Mass-Timber-Buildings問題集デーモをダウンロードします。
質問 # 44
Refer to the exhibit by clicking on the EXHIBIT button above.
In the detail shown, if the connections between the glulam beam and CLT panels all require a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire 1 hour of protection, what is the minimum thickness and number of layers required for the locations shown in red?
正解:D
解説:
Two layers of 5/8-inch Type X gypsum wallboard are required for the condition shown, so option D is correct. The relevant AWC TR10 connection-protection methodology distinguishes between outer gypsum layers and the base layer immediately adjacent to the connection .
For 5/8-inch Type X gypsum board, an outer layer contributes 40 minutes. However, when gypsum board is being relied upon as the complete thermal-separation protection for a connection, TR10 reduces the contribution of the final/base layer to 50 percent. Therefore, the base layer contributes 20 minutes , while the second, exterior layer contributes 40 minutes . The total is:
20 minutes + 40 minutes = 60 minutes .
That satisfies the one-hour required protection period.
This is why simply looking at the normal 40-minute contribution of one 5/8-inch Type X layer would be incorrect for this connection condition. TR10 expressly uses the reduced base-layer contribution when gypsum constitutes the connection protection. The same methodology shows that four 5/8-inch Type X layers are needed for 120 minutes: 20 + 40 + 40 + 40 = 140 minutes, satisfying two hours.
References/Topics: AWC Technical Report No. 10, Sections 4.4.2 and connection-protection examples. TR10 states that outer 5/8-inch Type X layers provide 40 minutes each while the base layer provides 20 minutes.
質問 # 45
Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?
正解:B
解説:
Option A is an exact requirement of the 2021 International Fire Code Section 3303.5 . For Type IV-A, IV- B, and IV-C buildings designed to exceed six stories above grade plane, standpipes must be provided in accordance with IFC Section 3313, unless otherwise approved by the fire code official.
The IFC also requires a water supply for fire department operations, but that supply must be approved by the fire code official and fire chief; the code does not specifically mandate that it be a "portable" water supply.
Option B is therefore incorrect.
The remaining options alter important numerical requirements. Where noncombustible protection is required and construction exceeds six stories, at least one layer , not two, must be installed on applicable building elements more than four levels below active mass timber construction before additional floor levels are erected. Required exterior wall coverings are likewise required more than four levels below active mass timber construction, rather than two.
These safeguards reduce the amount of exposed combustible construction while ensuring that effective fire department infrastructure progresses with the building.
References/Topics: 2021 IFC Section 3303.5; Sections 3313 and related construction-stage fire protection requirements.
質問 # 46
For a sprinklered Business Occupancy (Group B) in a 15-story building of Type IV-A construction, the maximum allowable building area is:
正解:C
解説:
The calculation begins with 2021 IBC Table 506.2. Because the building is a Group B occupancy, has more than one story, and is protected throughout by an automatic sprinkler system complying with Section
903.3.1.1, the applicable tabular classification is "SM"-a multistory, fully sprinklered building.
For Group B and Type IV-A construction, Table 506.2 assigns an SM allowable area factor of 324,000 square feet. However, this is not the final total allowable building area. Section 506.2.1 requires a single-occupancy building with more than three stories above grade plane to use Equation 5-2. Where no frontage increase is stated, the calculation is:
324,000 square feet × 3 = 972,000 square feet.
The story-area multiplier is limited to three even though the building contains 15 stories. The code does not permit multiplying 324,000 square feet by all 15 stories. Additionally, the actual area of an individual story cannot exceed its calculated allowable area. Option A represents a different construction-type area factor, while option B does not result from the required IBC multistory calculation. The building is not automatically unlimited merely because it is Type IV-A and sprinklered.
References/Topics: 2021 IBC Sections 506.2 and 506.2.1; Equation 5-2; Table 506.2, Group B, Type IV-A, SM area factor.
質問 # 47
Each of the following is true for special inspection of mass timber construction except:
正解:B
解説:
Option A is the false statement. Under 2021 IBC Table 1705.5.3, bolted connections require periodic special inspection, not continuous special inspection.
The remaining three statements correspond directly to items contained in the table. Concealed connections are subject to periodic inspection. Erection of mass timber construction is also periodically inspected. For threaded fasteners, the inspector must periodically verify the use of pre-drilled holes where the approved design or manufacturer's installation requirements call for them.
The distinction between periodic and continuous inspection is fundamental. Periodic inspection means the special inspector observes the work at appropriate intervals sufficient to verify compliance. Continuous inspection requires the inspector to be present continuously during the performance of the regulated work.
Table 1705.5.3 reserves continuous inspection for the particularly installation-sensitive condition involving adhesive anchors installed horizontally or upwardly inclined to resist sustained tension loads.
For bolted connections, periodic inspection remains technically substantive. The inspector should verify bolt size and type, hole preparation, connection geometry, washers and nuts, required tightening, member condition, edge and end distances, and conformity with the approved structural drawings.
References/Topics: 2021 IBC Section 1705.5.3; Table 1705.5.3, Required Special Inspections of Mass Timber Construction.
質問 # 48
The building owner shall be responsible for each of the following for fire safety during construction except:
正解:B
解説:
The IFC does not require daily inspection documentation to be stored in a fire- and water-resistant safe.
Therefore, option C is the exception.
The owner or the owner's authorized agent must establish and maintain the required construction-site fire- prevention program and designate a site safety director. The site safety director is responsible for completing a daily fire-safety inspection covering the building and exterior project areas. The results must be documented, retained on-site until the certificate of occupancy is issued, and made immediately available to the fire code official upon request. Options A, B, and D accurately reflect these administrative requirements.
The purpose is not merely record retention. Daily inspections are intended to identify conditions such as obstructed fire apparatus access, blocked hydrants or fire department connections, exposed temporary wiring, improper hazardous-material storage, uncontrolled combustible debris, unavailable extinguishers, impaired standpipes, and deficient hot-work controls.
A special inspector is not automatically the site safety director. However, observations involving installed passive protection or unsafe construction conditions should be communicated through the approved reporting process. The owner remains accountable for implementing the site safety plan and maintaining the required documentation.
References/Topics: 2021 IFC Sections 3303.1 through 3303.3; site safety director and daily fire-safety inspection records.