The proximity of perfection on our H20-923_V1.0 practice dumps is outstanding. By using our H20-923_V1.0 preparation materials, we are sure you will pass your exam smoothly and get your dreamed certification. We have a variety of versions for your reference: PDF & Software & APP version. All those versions are high efficient and accurate with passing rate up to 98 to 100 percent. So our H20-923_V1.0 Study Guide is efficient, high-quality for you.
| Certification Vendor: | Huawei |
|---|---|
| Exam Name: | HCSP-Field-Data Center Facility V1.0 |
| Exam Number: | H20-923_V1.0 |
| Exam Format: | Drag-and-drop, True/False, Single-answer, Multiple-answer |
| Passing Score: | 600/1000 |
| Exam Duration: | 90 minutes |
| Related Certifications: | Huawei Certified Solution Specialist (HCSP) |
| Exam Price: | USD 300 |
| Real Exam Qty: | 60 |
| Certificate Validity Period: | 3 Years |
| Available Languages: | Chinese, English |
| Sample Questions: | Huawei H20-923_V1.0 Sample Questions |
| Exam Way: | Pearson VUE |
| Pre Condition: | None |
| Official Syllabus URL: | https://e.huawei.com/en/talent/exam/#/cert/6000000000000000020 |
>> H20-923_V1.0 Exam Pass Guide <<
By doing this the successful H20-923_V1.0 candidates can gain several personal and professional benefits in their career and achieve their professional career objectives in a short time period. To attain this you just need to enroll in the Huawei H20-923_V1.0 Certification Exam and put all your efforts to pass this challenging H20-923_V1.0 exam with good scores.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
| Topic 7 |
|
| Topic 8 |
|
| Topic 9 |
|
| Topic 10 |
|
| Topic 11 |
|
| Topic 12 |
|
| Topic 13 |
|
NEW QUESTION # 13
Which of the following smart module indicators is generally used to communicate operational health status via color coding (e.g., green/red)?
Answer: D
Explanation:
Huawei smart module components generally follow a consistent status LED convention where green indicates normal operation and red indicates a fault requiring attention, applied across multiple devices such as SPD, PDU, and controller status indicators -- not limited to just one component.
NEW QUESTION # 14
In a data center power distribution architecture, what is the primary function of a Static Transfer Switch (STS) for critical single-cord loads?
Answer: C
Explanation:
Huawei data center power distribution design prioritizes continuity for critical loads. For single- cord IT equipment that cannot accept dual inputs, an STS provides a practical high-availability approach by connecting the load to two independent AC sources (often A and B feeds) and transferring the load to the healthier source when abnormalities occur. The key value is speed and coordination: the STS detects voltage/frequency deviations or source failure and performs a rapid transfer to minimize or eliminate interruption seen by the load. This supports O&M strategies where upstream systems (UPS, PDUs, distribution boards) are maintained or isolated without forcing downtime on single-cord devices. In routine operations, STS status, transfer logs, alarms, and source quality parameters are monitored to prevent nuisance transfers and to ensure correct upstream selectivity and grounding. Correct commissioning also ensures the two sources meet synchronization conditions and that bypass/maintenance procedures are standardized, improving safety and reducing operational risk.
NEW QUESTION # 15
After installing the FusionCol8000-C (110-440 kW), inject water to preserve the pressure for the chilled water pipes to how many MPa. After 30 minutes, check that no leakage occurs. Preserve the pressure for 24 hours. If the pressure drop is less than 0.01 MPa and no leakage occurs, the pipes do not leak.
Answer: B
Explanation:
For FusionCol8000-C chilled-water systems, Huawei commissioning requires awater leakage/pressure- holding teston the chilled-water piping after installation to verify joint sealing, valve interfaces, and connection integrity before long-term operation. The specified method is toraise the water pressure in the chilled-water pipe to 0.8 MPa, then observe for30 minutesto confirm there is no visible leakage. If the system remains dry, the same pressure isretained for 24 hoursas a stability verification step. The acceptance criterion is that thepressure drop is less than 0.01 MPaover the 24-hour period and no leakage is found, which demonstrates that the piping and fittings meet tightness requirements under the prescribed test pressure. This procedure helps prevent future failures such as slow seepage, corrosion around joints, insulation waterlogging, and unexpected shutdowns caused by water loss or low differential pressure alarms. It also ensures that subsequent flushing, venting, and operational commissioning can be performed safely and reliably.
NEW QUESTION # 16
Which of the following models is a Huawei in-room chilled water horizontal air supply product?
Answer: C
Explanation:
Huawei room-level air conditioning products are commonly identified by the series name plus a model suffix that indicates the cooling medium and airflow form factor. Anin-room chilled waterunit uses a chilled-water coil as the primary heat-exchange component and relies on the building's chilled-water system (chiller/plant) rather than an onboard refrigeration compressor for cooling generation. "Horizontal air supply" describes the discharge direction: the unit supplies conditioned air laterally into the room or into a specific airflow organization (such as cold-aisle delivery), supporting predictable airflow paths and stable return air conditions. Within the provided options,FusionCol5000-A050His the model that matches both identifiers: it belongs to Huawei's room cooling product line and the model code indicates an in-room configuration withchilled-watercapability andhorizontalair supply orientation. The other options belong to different series or represent configurations typically associated with other deployment forms (such as different placement, airflow direction, or system architecture). Therefore, the correct selection isFusionCol5000-A050H.
NEW QUESTION # 17
Which of the following interfaces is used to connect the controller and the main control module of the unit?
Answer: C
Explanation:
In Huawei precision cooling units, the LCD controller (human-machine interface) must exchange real-time operating data and commands with the unit's main control module while also receiving a stable low-voltage power supply. This connection is typically implemented as a low-voltage communication bus plus DC power, which is why the interface is identified as I2C/12V. The I2C portion provides the data channel used for status display, parameter viewing/setting (within permission scope), alarm presentation, and command delivery (such as mute, reset, or control enable actions). The 12 V portion supplies power to the controller so it can operate independently of high-voltage power circuits and remain safe to access during routine O&M. Interfaces like DP and USB are not used as the internal control link between the HMI and the main control board in this type of unit, and "SW" is not the designated controller-to-main-board interface in the standard wiring definition. Therefore, I2C/12V is the correct selection.