DOWNLOAD the newest BraindumpQuiz NCM-MCI-6.10 PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1x7WNBnN1tIIeA-0RvfxdvoOWA2dDs4fy
BraindumpQuiz releases 100% pass-rate Nutanix NCM-MCI-6.10 study guide files which guarantee candidates 100% pass exam in the first attempt. It is time for you to choose a valid Nutanix NCM-MCI-6.10 study guide, this will be your best method for clearing exam and obtain a certification. Good NCM-MCI-6.10 Study Guide will be a shortcut for you to well-directed prepare and practice efficiently, you will avoid do much useless efforts and do something interesting.
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Network Performance and Security | 20% | - Tune overlay networking and traffic flow - Optimize physical and virtual network configurations - Network troubleshooting and optimization - Implement and analyze Flow security policies |
| Topic 2: Monitoring, Automation and Operational Efficiency | 5% | - Operational process optimization - Automation workflows and tools - Monitoring and alerting configuration |
| Topic 3: Virtualization and VM Performance Optimization | 15% | - High availability and migration management - Performance metrics analysis and tuning - VM resource adjustment and optimization - AHV administration and workload management |
| Topic 4: Business Continuity and Disaster Recovery | 15% | - Disaster recovery strategy implementation - BCDR testing and validation - Replication and recovery configuration - Failover and failback operations |
| Topic 5: Advanced Platform Configuration and Troubleshooting | 25% | - Integration with third-party systems - Security configuration and compliance - Prism Central and Prism Element configuration - Cluster management, expansion and maintenance - API and CLI-based operations |
| Topic 6: Analyze and Optimize Storage Performance | 20% | - Understand storage internals and I/O patterns - Troubleshoot storage performance bottlenecks - Optimize storage configuration and settings - Evaluate and resolve competing workload requirements |
>> NCM-MCI-6.10 Latest Real Exam <<
Obtaining valid training materials will accelerate the way of passing Nutanix NCM-MCI-6.10 actual test in your first attempt. It will just need to take one or two days to practice Nutanix NCM-MCI-6.10 Test Questions and remember answers. You will free access to our test engine for review after payment.
NEW QUESTION # 11
Task 16
An administrator is working to create a VM using Nutanix V3 API calls with the following specifications.
* VM specifications:
* vCPUs: 2
* Memory: BGb
* Disk Size: 50Gb
* Cluster: Cluster A
* Network: default- net
The API call is falling, indicating an issue with the payload:
The body is saved in Desktop/ Files/API_Create_VM,text
Correct any issues in the text file that would prevent from creating the VM. Also ensure the VM will be created as speeded and make sure it is saved for re-use using that filename.
Deploy the vm through the API
Note: Do not power on the VM.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
https://portal.nutanix.com/page/documents/kbs/details?targetId=kA00e000000LLEzCAO
https://jsonformatter.curiousconcept.com/#
acli net.list (uuid network defult_net)
ncli cluster info (uuid cluster)
Put Call: https://Prism Central IP address : 9440/api/nutanix/v3vms
Edit these lines to fix the API call, do not add new lines or copy lines.
You can test using the Prism Element API explorer or PostMan
Body:
{
{
"spec": {
"name": "Test_Deploy",
"resources": {
"power_state":"OFF",
"num_vcpus_per_socket": ,
"num_sockets": 1,
"memory_size_mib": 8192,
"disk_list": [
{
"disk_size_mib": 51200,
"device_properties": {
"device_type":"DISK"
}
},
{
"device_properties": {
"device_type":"CDROM"
}
}
],
"nic_list":[
{
"nic_type": "NORMAL_NIC",
"is_connected": true,
"ip_endpoint_list": [
{
"ip_type": "DHCP"
}
],
"subnet_reference": {
"kind": "subnet",
"name": "default_net",
"uuid": "00000000-0000-0000-0000-000000000000"
}
}
],
},
"cluster_reference": {
"kind": "cluster",
"name": "NTNXDemo",
"uuid": "00000000-0000-0000-0000-000000000000"
}
},
"api_version": "3.1.0",
"metadata": {
"kind": "vm"
}
}
https://www.nutanix.dev/2019/08/26/post-a-package-building-your-first-nutanix-rest-api-post-request/ Reference
NEW QUESTION # 12
The security team has provided some new security requirements for cluster level security on Cluster 2.
Security requirements:
* Update the password for the root user on the Cluster 2 node to match the admin user password.
Note: The 192.168.x.x network is not available. To access a node use the host IP (172.30.0.x) from the CVM.
* Output the cluster-wide configuration of the SCMA policy to desktop\output.txt before changes are made.
* Enable the Advanced Intrusion Detection Environment (AIDE) to run on a weekly basis for the hypervisor and cvms for Cluster 2.
* Enable high-strength password policies for the hypervisor and cluster.
* Ensure CVMs require SSH keys for login instead of passwords. (SSH keys are located in the desktop\Files\SSH folder.) Ensure the cluster meets these requirements. Do not reboot any cluster components.
Note: Please ensure you are modifying the correct components.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to apply the security requirements to Cluster 2.
1. Access Cluster 2 Prism Element
First, we must access the Prism Element (PE) interface for Cluster 2, as most security settings are cluster- specific.
* From the Prism Central dashboard, navigate to Hardware > Clusters.
* Find Cluster 2 in the list and click its name. This will open the Prism Element login page for that specific cluster in a new tab.
* Log in to Cluster 2's Prism Element using the admin credentials.
2. Requirement: Update Node Root Password
This task syncs the root password for all AHV hypervisor nodes with the cluster's admin user password.
* In the Cluster 2 PE interface, click the gear icon (Settings) in the top right corner.
* Select Cluster Lockdown from the left-hand menu.
* Click the Set Root Password on All Hosts button.
* A dialog box will appear. Enter the current admin password (the one you just used to log in) into both the New Password and Confirm New Password fields.
* Click Save. This will propagate the admin password to the root user on all nodes in Cluster 2.
3. Requirement: Add CVM SSH Key
This task adds the security team's public key to the admin user, which is required before we can disable password-based login.
* On the desktop, navigate to the Files > SSH folder.
* Open the id_rsa.pub file (or equivalent public key file) with Notepad.
* Copy the entire string of text (e.g., ssh-rsa AAAA...).
* In the Cluster 2 PE interface, go to Settings (gear icon) > User Management.
* Select the admin user and click Modify User.
* Paste the copied public key into the Public Keys text box.
* Click Save.
4. Requirement: Apply SCMA Policies (All other requirements)
The remaining requirements are all applied via the command line on a CVM using Nutanix's Security Configuration Management Automation (SCMA).
* Access the CVM:
* Find a CVM IP for Cluster 2 by going to Hardware > CVMs in the PE interface.
* Open an SSH client (like PuTTY) and connect to that CVM's IP address.
* Log in with the username admin and the corresponding password.
* Output Current Policy (Req 2):
* Before making changes, run the following command to see the current policy:
ncli scma status
* Copy the entire output from your SSH terminal.
* Open Notepad on the desktop, paste the copied text, and Save the file to the desktop as output.
txt.
* Apply New Policies (Req 3, 4, 5):
* Run the following commands one by one. The cluster will apply them immediately without a reboot.
* Enable AIDE (Req 3):
ncli scma update aide-status=enabled aide-schedule=weekly
* Enable High-Strength Passwords (Req 4):
ncli scma update password-policy=high
* Require SSH Keys for CVMs (Req 5):
ncli scma update ssh-login=keys-only
Verification
You can verify all changes by running the status command again. The output should now reflect the new, hardened security posture.
ncli scma status
* AIDE Status: should show Enabled
* AIDE Schedule: should show Weekly
* Password Policy: should show High
* SSH Login: should show keys-only
NEW QUESTION # 13
Task 10
An administrator will be deploying Flow Networking and needs to validate that the environment, specifically switch vs1, is appropriately configured. Only VPC traffic should be carried by the switch.
Four versions each of two possible commands have been placed in Desktop\Files\Network\flow.txt. Remove the hash mark (#) from the front of correct First command and correct Second command and save the file.
Only one hash mark should be removed from each section. Do not delete or copy lines, do not add additional lines. Any changes other than removing two hash marks (#) will result in no credit.
Also, SSH directly to any AHV node (not a CVM) in the cluster and from the command line display an overview of the Open vSwitch configuration. Copy and paste this to a new text file named Desktop\Files\Network\AHVswitch.txt.
Note: You will not be able to use the 192.168.5.0 network in this environment.
First command
#net.update_vpc_traffic_config virtual_switch=vs0
net.update_vpc_traffic_config virtual_switch=vs1
#net.update_vpc_east_west_traffic_config virtual_switch=vs0
#net.update_vpc_east_west_traffic_config virtual_switch=vs1
Second command
#net.update_vpc_east_west_traffic_config permit_all_traffic=true
net.update_vpc_east_west_traffic_config permit_vpc_traffic=true
#net.update_vpc_east_west_traffic_config permit_all_traffic=false
#net.update_vpc_east_west_traffic_config permit_vpc_traffic=false
Answer:
Explanation:
First, you need to open the Prism Central CLI from the Windows Server 2019 workstation. You can do this by clicking on the Start menu and typing "Prism Central CLI". Then, you need to log in with the credentials provided to you.
Second, you need to run the two commands that I have already given you in Desktop\Files\Network\flow.txt.
These commands are:
net.update_vpc_traffic_config virtual_switch=vs1 net.update_vpc_east_west_traffic_config permit_vpc_traffic=true These commands will update the virtual switch that carries the VPC traffic to vs1, and update the VPC east- west traffic configuration to allow only VPC traffic. You can verify that these commands have been executed successfully by running the command:
net.get_vpc_traffic_config
This command will show you the current settings of the virtual switch and the VPC east-west traffic configuration.
Third, you need to SSH directly to any AHV node (not a CVM) in the cluster and run the command:
ovs-vsctl show
This command will display an overview of the Open vSwitch configuration on the AHV node. You can copy and paste the output of this command to a new text file named Desktop\Files\Network\AHVswitch.txt.
You can use any SSH client such as PuTTY or Windows PowerShell to connect to the AHV node. You will need the IP address and the credentials of the AHV node, which you can find in Prism Element or Prism Central.
remove # from greens
On AHV execute:
sudo ovs-vsctl show
CVM access AHV access command
nutanix@NTNX-A-CVM:192.168.10.5:~$ ssh root@192.168.10.2 "ovs-vsctl show" Open AHVswitch.txt and copy paste output
NEW QUESTION # 14
TASK 1
A newly created Windows VM "SQL02" is experiencing poor storage performance when compared to
"SQL01" running within the same cluster, on the same storage container.
The cluster is in a healthy state.
Create a new session named Monitor SQL02 with meaningful metrics. Right click on the session page and click Select All then paste this into Notepad and save it as Task 1.txt on the desktop.
Also, save the analysis as a report named MonitorSQL02 and send the report as a PDF on a daily basis to perf_group@ACME.org. Reports should not be retained. If any new objects need to be created, use monitovm2 in the name.
Finally, correct the issue within "SQL02".
Notes:
* Do not power on the VMs.
* While you will be creating a session, you will need to examine the VM configurations to determine the issue.
* Do not delete the VM to resolve the issue, any other destructive change is acceptable.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to all three tasks, performed within the Nutanix Prism interface.
Task 1: Create Monitoring Session & Save Metrics
* From the Prism Central dashboard, navigate to Operations > Analysis.
* Click the + New Session button.
* Name the session Monitor SQL02.
* In the "Entities" search box, type SQL01 and select VM: SQL01.
* In the "Entities" search box, type SQL02 and select VM: SQL02.
* Click Add Charts > New Chart.
* Title: Storage IOPS
* Metric: Storage Controller IOPS
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Latency
* Metric: Storage Controller Latency
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Bandwidth
* Metric: Storage Controller Bandwidth
* Click Add.
* Click Save Session.
* With the "Monitor SQL02" session open, right-click anywhere on the page and click Select All.
* Right-click again and select Copy.
* Open Notepad, paste the content, and save the file to the desktop as Task 1.txt.
(The content pasted into Task 1.txt would be the session's chart configurations, showing metrics for SQL01 and SQL02.)
Task 2: Create and Schedule the Report
* While still in the "Monitor SQL02" analysis session, click the Save as Report button (it looks like a bookmark icon).
* Name the report MonitorSQL02 and click Save.
* Navigate to Operations > Reports.
* Find the MonitorSQL02 report in the list. Select its checkbox.
* Click the Actions dropdown and select Schedule.
* Configure the schedule with the following settings:
* Schedule Name: monitovm2_daily_report
* Recurrence: Daily
* Start Time: (Set to a time, e.g., 8:00 AM)
* Repeat every: 1 day(s)
* Retention Policy: Uncheck the "Retain a copy of the report" box. (This ensures reports are not retained).
* Email Report: Check this box.
* Format: PDF
* Recipients: perf_group@ACME.org
* Click Save.
Task 3: Identify and Correct the Performance Issue
This task is performed without powering on the VMs, indicating a configuration error.
Investigation
* Navigate to VMs > Table view.
* Click on the SQL01 (the good VM) and select the Configuration tab.
* Expand the Disks section. Observe that the primary disk is attached to a SCSI bus (e.g., scsi.0). This is the high-performance standard.
* Return to the VM list and click on SQL02 (the problem VM).
* Expand the Disks section.
Root Cause
You discover that the primary disk for SQL02 is attached to an IDE bus. The IDE bus has significant performance limitations and is not suitable for a database server, causing the poor storage performance.
Correction
* With the SQL02 VM selected, click the Update button.
* In the "Update VM" dialog, scroll down to the Disks section.
* Find the disk attached to the IDE bus. Click the Edit (pencil) icon for that disk.
* Change the Bus Type dropdown from IDE to SCSI.
* The Device Index will automatically populate (e.g., scsi.0).
* Click Save in the "Update Disk" dialog.
* (Note: A "VirtIO SCSI Controller" will be automatically added to the VM configuration if one was not already present.)
* Click Save in the "Update VM" dialog.
The VM SQL02 is now configured to use the high-performance VirtIO-SCSI controller, which will resolve the storage performance discrepancy once the VM is powered on.
NEW QUESTION # 15
Task 13
An administrator found a CentOS VM, Cent_Down, on the cluster with a corrupted network stack. To correct the issue, the VM will need to be restored from a previous snapshot to become reachable on the network again.
VM credentials:
Username: root
Password: nutanix/4u
Restore the VM and ensure it is reachable on the network by pinging 172.31.0.1 from the VM.
Power off the VM before proceeding.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
To restore the VM and ensure it is reachable on the network, you can follow these steps:
Log in to the Web Console of the cluster where the VM is running.
Click on Virtual Machines on the left menu and find Cent_Down from the list. Click on the power icon to power off the VM.
Click on the snapshot icon next to the power icon to open the Snapshot Management window.
Select a snapshot from the list that was taken before the network stack was corrupted. You can use the date and time information to choose a suitable snapshot.
Click on Restore VM and confirm the action in the dialog box. Wait for the restore process to complete.
Click on the power icon again to power on the VM.
Log in to the VM using SSH or console with the username and password provided.
Run the command ping 172.31.0.1 to verify that the VM is reachable on the network. You should see a reply from the destination IP address.
Go to VMS from the prism central gui
Select the VMand go to More -> Guest Shutdown
Go to Snapshots tab and revert to latest snapshot available
power on vm and verify if ping is working
NEW QUESTION # 16
......
The product BraindumpQuiz provide with you is compiled by professionals elaborately and boosts varied versions which aimed to help you learn the pass your NCM-MCI-6.10 exam by the method which is convenient for you. We check the update every day, and we can guarantee that you will get a free update service from the date of purchase. Once you have any questions and doubts about our NCM-MCI-6.10 Exam Questions we will provide you with our customer service before or after the sale.
Reliable NCM-MCI-6.10 Test Practice: https://www.braindumpquiz.com/NCM-MCI-6.10-exam-material.html
P.S. Free 2026 Nutanix NCM-MCI-6.10 dumps are available on Google Drive shared by BraindumpQuiz: https://drive.google.com/open?id=1x7WNBnN1tIIeA-0RvfxdvoOWA2dDs4fy