BTW, DOWNLOAD part of BraindumpStudy VTNE dumps from Cloud Storage: https://drive.google.com/open?id=1-ZOimBBVcNygM4uJlQaIeK6wMYdMksuA
The valid updated, and real AAVSB VTNE PDF questions and both practice test software are ready to download. Just take the best decision of your professional career and get registered in AAVSB VTNE certification exam and start this journey with BraindumpStudy VTNE exam PDF dumps and practice test software. All types of AAVSB Exam Questions formats are available at the best price.It will enable you to perform well in the final VTNE Exam. BraindumpStudy offers VTNE exam study material in the three best formats. AAVSB VTNE Exam Questions, Web-based and desktop practice exam software. All these formats play a vital role in your AAVSB VTNE exam preparation process.
| Section | Objectives |
|---|---|
| Topic 1: Diagnostic Imaging | - Image processing and interpretation basics - Radiography positioning and safety |
| Topic 2: Anesthesia | - Anesthetic monitoring - Anesthetic protocols and equipment |
| Topic 3: Laboratory Procedures | - Urinalysis and microbiology - Hematology and clinical pathology |
| Topic 4: Pain Management and Analgesia | - Analgesic drug use - Pain assessment techniques |
| Topic 5: Animal Care and Nursing | - Patient handling and restraint - Nutrition and husbandry |
| Topic 6: Pharmacology | - Dosage calculations and administration - Drug classifications and uses |
| Topic 7: Dentistry | - Oral anatomy and disease recognition - Dental prophylaxis procedures |
| Topic 8: Emergency Medicine and Critical Care | - Shock management and CPR - Triage and stabilization |
| Topic 9: Surgical Nursing | - Preoperative and postoperative care - Sterile technique and instrumentation |
You can get an idea about the actual VTNE test pattern and VTNE exam questions. It will also assist you to enhance your AAVSB VTNE exam time management skills. You can easily use all these three VTNE exam questions format. These formats are compatible with all devices, operating systems, and the latest browsers. All three AAVSB VTNE Exam Questions formats are easy to use and compatible with all devices, operating systems, and the latest browsers.
NEW QUESTION # 583
Generally speaking, all of the following items would be safe to use in or near an MRI unit, except which one?
Answer: B
Explanation:
Generally speaking, metal is always unsafe near the MRI unit. The magnetic field is always on, so it is never safe to take metal objects into the room unless they are specifically designed for MRI use (which is rare).
Assume any iron-containing metals are unsafe near the MRI unit. If you don't know a metal object's complete makeup, it is safer to assume it will be attracted to the magnetic field and, thus, should be avoided.
The more ferromagnetic (iron-containing) a material, the more likely it will be attracted to the magnetic field. This renders iron, nickel, cobalt, and some stainless steel unsafe to be taken near the unit.
Microchips will produce an artifact but are safe within the MRI.
Contrast studies are feasible despite the strong magnetic field in an MRI. Paramagnetic contrast agents must be used. Unlike the contrast agents used in CT, gadolinium does not react with the magnetic field. It can be used to help enhance tissue images and display vascular areas and pathology within areas of concern.
Many people and animals have metal implants, from hip replacements to pins, from surgical orthopedic repair. These products are usually made of titanium due to their strength properties and the body's ability to accept the implanted material. Many people and animals need imaging done even with implants, and titanium, a non-magnetic, non-iron-containing metal, remains safe to use in or around MRI units.
NEW QUESTION # 584
Cytotoxic waste must be disposed of properly and safely at all times. Biomedical waste is just as concerning and poses health risks as sharps and chemicals may pose health concerns.
All of the following may consist of cytotoxic waste, except:
Answer: C
Explanation:
Cytotoxic waste consists of bodily fluids that could be contaminated with a chemotherapeutic agent. These include urine, feces, and vomitus most commonly, but any body fluid could pose a risk. Liver tissue, for example, from a biopsy, is unlikely to have cytotoxic waste, but disposing of it with other potentially chemotherapeutically contaminated products is never wrong.
For animals receiving chemotherapeutic agents, for a minimum of 48 hours, their waste should be considered contaminated and handled appropriately. For some agents or radiation, such as I131 for thyroid tumors, debris could be affected for longer durations.
Patient waste should be properly disposed of in containers specifically for hazardous waste.
Dogs treated with chemo medications should be permitted to only urinate in low-traffic areas. Ideally, these areas should have excellent exposure to sunlight to help degrade the chemicals faster.
For cats treated with chemo agents, litter and related materials need to be disposed of in a chemotherapeutic-approved waste container.
Always ensure that you always wash your hands after handling any patient waste, even when wearing appropriate protective clothing, including gloves.
NEW QUESTION # 585
How many milliliters of 50% dextrose solution will you need to add to 1.0 liter of LRS to make a 5% dextrose solution?
Answer: B
Explanation:
100 mL of 50% dextrose solution is required to make a 5% dextrose solution using 1 liter of LRS.
Technically, 100 mL of the LRS must be removed from the 1000 mL bag prior to adding dextrose so that the final volume is 1000 mL once it is added.
Calculation:
*Multiply the final volume by the concentration of the solution to be made: 1,000 mL x 5% = 50 mL
*Since the stock dextrose solution is 50% concentration instead of 100%, divide 50 mL by 50%: 50 mL / 50% = 50 ml / 0.50 = 100 mL
NEW QUESTION # 586
A newborn calf mineral supplement label states that it includes 125 mg/kg of iodine. An independent lab analysis reports the product as containing 200 ppm of iodine in the product. The producer wants to know how these compare.
Which statement is correct?
Answer: B
Explanation:
Conversion factor to remember: 1 part per million = 1 mg/kg
To re-derive this conversion factor: 1 mg/kg = 0.001g/1000g. Multiply by 1,000/1,0000 = 1g/1,000,000g. Cancel out the units to achieve 1/1,000,000 or one part per one million.
The lab testing says there is 200, when there should only be 125, so 200/125 = 1.6 times more iodine in the product than is stated on the label.
NEW QUESTION # 587
Which of the following parasites is known to cause high morbidity and mortality rates in llamas and alpacas?
Answer: A
Explanation:
The meningeal worm, Parelaphostrongylus tenuis, is a parasite known to cause high morbidity and mortality rates in llamas and alpacas. White-tailed deer are the normal hosts of this parasite; however, it does not affect the deer. A meningeal worm infestation in llamas and alpacas may cause ataxia, stiffness, paralysis, weight loss, depression, and death. Dewormers can be used to treat this infestation in camelids.
Cystoisospora, Dipylidium, and Ancylostoma are parasites of dogs, not camelids.
Joanna M. Bassert, VMD. McCurnin's Clinical Textbook for Veterinary Technicians, 9th Edition. Pg 721-722.
Mosby's Comprehensive Review for Veterinary Technicians 5th Edition. Pg 641.
NEW QUESTION # 588
......
Therefore, it is indispensable to choose a trusted website for real VTNE dumps. BraindumpStudy is one of the most reliable platforms to get actual VTNE dumps. It offers the latest and valid real Veterinary Technician National Exam (VTNE) exam dumps. The product of BraindumpStudy is available in AAVSB VTNE PDF, desktop VTNE practice exam software, and web-based Veterinary Technician National Exam practice test.
VTNE Dumps Discount: https://www.braindumpstudy.com/VTNE_braindumps.html
P.S. Free & New VTNE dumps are available on Google Drive shared by BraindumpStudy: https://drive.google.com/open?id=1-ZOimBBVcNygM4uJlQaIeK6wMYdMksuA