EDGE EDGE-Expert Exam Syllabus Topics:

SectionWeightObjectives
Topic 1: Water Efficiency & Materials25%- Water Demand
  • 1. Rainwater harvesting, recycling and other conservation techniques
  • 2. Water sources (mains-supplied, recovered, recycled)
  • 3. Water-saving measures
  • 4. Base case water use in each building type
- Materials Embodied Energy (EE)
  • 1. Materials EE measures
  • 2. Base case definition
Topic 2: Financial & Results Analysis10%- Results and outputs of EDGE
  • 1. Baseline, utility savings, GHGs reduced
  • 2. Financial outputs in results bar
Topic 3: Energy Efficiency25%- Energy Consumption
  • 1. Overall energy demand of buildings
  • 2. Energy-saving measures
  • 3. Virtual energy for comfort
- HVAC Systems
  • 1. Technologies for Heating, Ventilation and Air Conditioning
- Lighting & Hot Water
  • 1. Energy demand for lighting
  • 2. Energy demand for hot water
Topic 4: Software & Methodology25%- Baseline & Proposed Building Models
  • 1. Basecase Definition
  • 2. Proposed Design Inputs
- Climate Zones & Weather Data
  • 1. Impact of Climate on Building Design
- EDGE Software Interface
  • 1. Data Entry Requirements
  • 2. User Interface Navigation
Topic 5: EDGE System Overview15%- EDGE Certification Process
  • 1. GBCI Certification Services
  • 2. Required Documentation
  • 3. Certification Steps
- Building Types & Applicability
  • 1. Residential
  • 2. Hospitality & Educational Buildings
  • 3. Commercial (Retail, Office, Hospital)
- Understanding the EDGE Standard
  • 1. Benefits of Green Buildings
  • 2. EDGE Categories (Energy, Water, Materials)
  • 3. EDGE Certification Program

>> EDGE-Expert인증시험 덤프공부 <<

높은 통과율 EDGE-Expert인증시험 덤프공부 시험덤프문제 다운받기

ExamPassdump을 선택함으로 100%인증시험을 패스하실 수 있습니다. 우리는EDGE EDGE-Expert시험의 갱신에 따라 최신의 덤프를 제공할 것입니다. ExamPassdump에서는 무료로 24시간 온라인상담이 있으며, ExamPassdump의 덤프로EDGE EDGE-Expert시험을 패스하지 못한다면 우리는 덤프전액환불을 약속 드립니다.

최신 GBCI EDGE EDGE-Expert 무료샘플문제 (Q86-Q91):

질문 # 86
The Client has sent a copy of the local occupancy permit for a project being audited. This permit:

정답:D

설명:
An occupancy permit indicates that a building meets local regulatory requirements for occupancy,but it does not address the specific green building measures required for EDGE certification. The EDGE Certification Protocol clearly outlines the role of such permits in the audit process: "A local occupancy permit provided by the Client confirms that the building complies with local building codes and is ready for use. However, it does not replace the need to audit all EDGE measures, as EDGE certification requires verification of specific energy, water, and materials efficiency measures that are not typically covered by local permits" (EDGE Certification Protocol, Section 3.4: Post-Construction Requirements). Option A, does not replace the need to audit all EDGE measures, directly aligns with this guidance, as the Auditor must still verify each claimed measure (e.g., insulation, low-flow fixtures, fly ash concrete) against EDGE standards. Option B (replaces the need to audit all EDGE measures) is incorrect, as the permit does not address EDGE-specific requirements:
"Local permits do not verify EDGE measures like energy savings or embodied energy reductions, so a full audit is still required" (EDGE Expert and Auditor Protocols, Section 4.4: Site Audit Procedures). Option C (does not replace the need for desktop studies) is partially correct but less comprehensive, as desktop studies are only one part of the audit process: "Desktop studies are part of the audit, but the occupancy permit does not exempt any aspect of the EDGE audit, including site visits and measure verification" (EDGE Certification Protocol, Section 3.2: Audit Requirements). Option D (replaces the need to audit EDGE Materials measures) is also incorrect, as materials measures (e.g., use of fly ash concrete) require specific evidence like manufacturer's data sheets, not covered by an occupancy permit: "Materials measures require detailed documentation of embodied energy reductions, which local permits do not address" (EDGE User Guide, Section 7.2: Materials Efficiency Measures). The EDGE User Guide further reinforces: "The Auditor must verify all EDGE measures through appropriate documentation and site visits, regardless of local permits, to ensure compliance with the EDGE standard" (EDGE User Guide, Section 6.3: Post-Construction Certification). Thus, the occupancy permit does not replace the need to audit all EDGE measures (Option A).
Reference:EDGE Certification Protocol, Section 3.4: Post-Construction Requirements, Section 3.2: Audit Requirements; EDGE Expert and Auditor Protocols, Section 4.4: Site Audit Procedures; EDGE User Guide Version 2.1, Section 6.3: Post-Construction Certification, Section 7.2: Materials Efficiency Measures.


질문 # 87
To claim efficiency measure Insulation for Cold Storage Envelope, which of the following documents is required as evidence at the preliminary certification stage?

정답:B

설명:
The preliminary certification stage requires specific documentation to verify the implementation of efficiency measures like Insulation for Cold Storage Envelope. The EDGE Certification Protocol outlines the evidence requirements: "For measures involving insulation, such as Insulation for Cold Storage Envelope, the Client must provide drawings at the preliminary certification stage that specify the U-value of the installed insulation to demonstrate compliance with the measure's requirements. The U-value must be lower than the Base Case to qualify for savings" (EDGE Certification Protocol, Section 3.2: Audit Requirements). Option C, drawings showing the U-value specification of the cold storage envelope, directly aligns with this requirement. Option A (calculations of Coefficient of Performance) is irrelevant, as COP applies to HVAC systems, not insulation:
"COP is used for chillers, not insulation measures" (EDGE User Guide, Section 4.2: Energy Efficiency Measures). Option B (manufacturer's data sheets for the HVAC system) is also unrelated, as the measure focuses on the envelope, not HVAC: "HVAC documentation is not required for insulation measures" (EDGE Certification Protocol, Section 3.2: Audit Requirements). Option D (purchase receipts showing the U-value) is more relevant at the post-construction stage: "Purchase receipts are typically required at the post-construction stage to confirm installation, while drawings suffice for design-stage verification" (EDGE Certification Protocol, Section 3.4: Post-Construction Requirements). Thus, drawings with U-value specifications (Option C) are required at preliminary certification.
Reference:EDGE Certification Protocol, Section 3.2: Audit Requirements, Section 3.4: Post-Construction Requirements; EDGE User Guide Version 2.1, Section 4.2: Energy Efficiency Measures.


질문 # 88
Utility cost savings are calculated based on reduction in total:

정답:A

설명:
Utility cost savings in EDGE are calculated based on reductions in resource consumption sourced from the supply grid, as these are the costs directly borne by the building owner. The EDGE User Guide explains:
"Utility cost savings in EDGE are calculated based on the reduction in energy and water consumption from the supply grid, using local tariffs for electricity and water to convert resource savings into financial savings" (EDGE User Guide, Section 2.4: Interpreting EDGE Results). Option D, energy and water consumption from the supply grid, aligns with this definition, focusing on grid-supplied resources. Option A (electricity and water consumption) is partially correct but lacks specificity about the source: "Electricity and water must be grid-supplied to be included in utility cost savings; onsite generation is excluded" (EDGE Methodology Report Version2.0, Section 4.4: Cost Savings Calculations). Option B (generator fuel and water consumption) is incorrect, as generator fuel is not part of utility cost savings: "Generator fuel costs are not included in utility savings, as EDGE focuses on grid-supplied utilities" (EDGE User Guide, Section 2.4: Interpreting EDGE Results). Option C (building energy and water consumption) is too broad, including onsite sources: "Building consumption includes all sources, but utility savings are grid-specific" (EDGE Methodology Report Version
2.0, Section 4.4: Cost Savings Calculations). Thus, energy and water from the supply grid (Option D) is the correct basis for utility cost savings.
Reference:EDGE User Guide Version 2.1, Section 2.4: Interpreting EDGE Results; EDGE Methodology Report Version 2.0, Section 4.4: Cost Savings Calculations.


질문 # 89
A building owner tells an EDGE Auditor that water-efficient faucets are in the building's restrooms.
However, the specifications on the faucets are not provided. The Auditor should:

정답:A

설명:
EDGE Auditors must adhere to strict protocols ensuring that all claimed measures are supported by verifiable evidence, especially during audits. The EDGE Expert and Auditor Protocols state: "If a claimed measure, such as water-efficient faucets, lacks supporting documentation like specifications or manufacturer's data sheets, the Auditor must exclude the measure from the project assessment. The Auditor is not permitted to test equipment, substitute evidence, or mandate replacements, as their role is to verify, not rectify, the Client's submission" (EDGE Expert and Auditor Protocols, Section 4.2: Evidence Verification). Option A, exclude the faucets from the project, aligns with this protocol, as the lack of specifications prevents verification. Option B (test the faucets' flow rates) is incorrect, as Auditors cannot conduct tests: "Auditors are not responsible for testing equipment; they must rely on provided documentation" (EDGE Certification Protocol, Section 3.2:
Audit Requirements). Option C (require the owner to replace the faucets) oversteps the Auditor's role:
"Auditors cannot mandate changes to the project; they assess what is submitted" (EDGE Expert and Auditor Protocols, Section 2.3: Conflict of Interest). Option D (find a product with the same parameters) is also prohibited: "Auditors cannot substitute or assume evidence on behalf of the Client" (EDGE Expert and Auditor Protocols, Section 4.2: Evidence Verification). Thus, the Auditor should exclude the faucets (Option A).
Reference:EDGE Expert and Auditor Protocols, Section 4.2: Evidence Verification, Section 2.3: Conflict of Interest; EDGE Certification Protocol, Section 3.2: Audit Requirements.


질문 # 90
How many years of experience in related fields are required for applicants without a construction-related higher qualification to become an EDGE Expert?

정답:A

설명:
The eligibility criteria for becoming an EDGE Expert are designed to ensure candidates have sufficient background to advise on green building projects. The EDGE Expert and Auditor Protocols specify the requirements for candidates without a construction-related higher qualification: "Applicants without a higher education qualification in a construction-related field (e.g., architecture, engineering) must have a higher education qualification in any field plus at least three years of experience in the construction industry as a skilled professional or tradesperson to qualify for EDGE Expert training and certification" (EDGE Expert and Auditor Protocols, Section 3.1: Eligibility Criteria). Option C, at least 3 years, directly matches this requirement. Option A (at least 1 year) and Option B (at least 2 years) are insufficient, as they fall below the minimum threshold: "Less than three years of experience does not meet the eligibility criteria for candidates without a construction-related degree, as this duration ensures adequate practical knowledge of building design and construction processes" (EDGE Expert and Auditor Protocols, Section 3.1: Eligibility Criteria).
Option D (at least 5 years) exceeds the minimum requirement, which is not necessary: "While additional experience is beneficial, the minimum requirement for EDGE Expert eligibility is three years for non- construction degree holders" (EDGE User Guide, Section 6.4: Working with EDGE Experts). The EDGE Certification Protocol also notes: "The three-year experience requirement for non-construction graduates ensures that EDGE Experts have sufficient industry exposure to provide meaningful consultancy, balancing accessibility with competence" (EDGE Certification Protocol, Section 1.3: Program Structure). Additionally, the EDGE User Guide clarifies: "Candidates with a construction-related degree are exempt from the experience requirement, but those without such a degree must demonstrate at least three years of relevant experience to qualify for the EDGE Expert exam" (EDGE User Guide, Section 6.4: Working with EDGE Experts). Therefore, at least 3 years of experience (Option C) is required for applicantswithout a construction- related higher qualification.
Reference:EDGE Expert and Auditor Protocols, Section 3.1: Eligibility Criteria; EDGE Certification Protocol, Section 1.3: Program Structure; EDGE User Guide Version 2.1, Section 6.4: Working with EDGE Experts.