BTW, DOWNLOAD part of ExamBoosts NCM-MCI-6.10 dumps from Cloud Storage: https://drive.google.com/open?id=12r3ei6rkEF8q30w8dMRc5N9smuoBVxhk
ExamBoosts is a website which is able to speed up your passing the Nutanix certification NCM-MCI-6.10 exams. Our Nutanix certification NCM-MCI-6.10 exam question bank is produced by ExamBoosts's experts's continuously research of outline and previous exam. When you are still struggling to prepare for passing the Nutanix certification NCM-MCI-6.10 Exams, please choose ExamBoosts's latest Nutanix certification NCM-MCI-6.10 exam question bank, and it will brings you a lot of help.
| Section | Weight | Objectives |
|---|---|---|
| Business Continuity and Disaster Recovery | 15% | - Replication and recovery configuration - BCDR testing and validation - Failover and failback operations - Disaster recovery strategy implementation |
| Network Performance and Security | 20% | - Network troubleshooting and optimization - Tune overlay networking and traffic flow - Implement and analyze Flow security policies - Optimize physical and virtual network configurations |
| Advanced Platform Configuration and Troubleshooting | 25% | - Security configuration and compliance - Integration with third-party systems - API and CLI-based operations - Cluster management, expansion and maintenance - Prism Central and Prism Element configuration |
| Monitoring, Automation and Operational Efficiency | 5% | - Automation workflows and tools - Monitoring and alerting configuration - Operational process optimization |
| Virtualization and VM Performance Optimization | 15% | - AHV administration and workload management - VM resource adjustment and optimization - High availability and migration management - Performance metrics analysis and tuning |
| Analyze and Optimize Storage Performance | 20% | - Understand storage internals and I/O patterns - Evaluate and resolve competing workload requirements - Troubleshoot storage performance bottlenecks - Optimize storage configuration and settings |
>> NCM-MCI-6.10 Certification Materials <<
Two Nutanix NCM-MCI-6.10 practice tests of ExamBoosts (desktop and web-based) create an actual test scenario and give you a NCM-MCI-6.10 real exam feeling. These NCM-MCI-6.10 Practice Tests also help you gauge your Nutanix Certification Exams preparation and identify areas where improvements are necessary.
NEW QUESTION # 20
An administrator regularly sees a WARN for backup_schedule_check and also receives alerts for Pulse not being enabled on Cluster 1.
Detailed information for backup_schedule_check:
Node xx.xx.xx.xx:
WARN: Backup schedule(s) exist for protection domain NoVMs; however, there are no entities in the protection domain.
Refer
to KB 1910 (http://portal.nutanix.com/kb/1910) for details on backup_schedule_check or Recheck with: ncc health_checks data_protection_checks protection_domain_checks backup_schedule_check.
This shows up in NCC, however, it is something set up by the company and they do not want the NCC check to be run.
Configure Cluster 1 to no longer have messages in NCC about the backup_schedule_check.
Turn off the alert for Pulse not being enabled, and resolve the alert. They would like messages about Pulse to be recorded, but do not want an alert.
Note: You may need to run the "Pulse is not enabled" check in order to have one to resolve.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to configure Cluster 1 from its Prism Element interface.
1. Disable the backup_schedule_check NCC Check
This will prevent the WARN message for the NoVMs protection domain.
* Log in to the Cluster 1 Prism Element (PE) interface.
* Navigate to the Health dashboard (click the "heart" icon in the top-left).
* In the left-hand menu, select NCC.
* In the search bar for the checks, type backup_schedule_check to find the specific check.
* Select the checkbox next to the backup_schedule_check in the list.
* Click the Disable button that appears above the table. This will stop this check from running during NCC health reports.
2. Configure and Resolve Pulse Alerts
This process involves two parts: disabling the alerting policy, and then enabling Pulse itself to resolve the underlying condition.
A. Disable the Alert Policy
This stops the system from generating a new alert if Pulse is ever disabled, satisfying the "do not want an alert" requirement.
* Click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Alert Policies.
* In the search bar, type Pulse to find the policy.
* Select the checkbox for the alert policy named Pulse is not enabled (or pulse_disabled_alert).
* Click the Update button.
* Uncheck the Enable box for the policy.
* Click Save.
B. Enable Pulse (to Resolve the Condition)
This enables the Pulse service to record messages (as requested) and fixes the root cause of the alert, allowing it to be resolved.
* Click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Pulse.
* Click the Enable Pulse button (or "Update" if it's already partially configured).
* Check the box for Enable Pulse.
* (Note: Any "Enable alerts for Pulse" boxes would remain unchecked or be ignored, as the main Alert Policy itself is now disabled.)
* Click Save.
C. Resolve the Active Alert
* Navigate to the Alerts dashboard (click the "bell" icon in the top-left).
* Find the active alert: Pulse is not enabled.
* (Note: If the alert is not present, you would first go to the Health dashboard, run the check_pulse NCC check to generate it, and then return to the Alerts dashboard.)
* Select the checkbox next to the "Pulse is not enabled" alert.
* Click the Resolve button that appears at the top of the list. Since the underlying condition (Pulse being disabled) is now fixed, the alert will be successfully resolved.
NEW QUESTION # 21
The Infosec team has requested that all operational tasks performed within Cluster 1 be properly logged to include the top 4 severity levels and pushed to their syslog system using highest reliability possible for analysis. This is to include any Virtual Machine changes only.
The Infosec team has also requested that monitor logs for the given RSyslog Server Module be included for now. No extra logs should be included.
No other clusters should connect to this syslog server.
Syslog configuration:
* Syslog Name: Corp_Syslog
* Syslog IP: 34.142.155.231
* Port: TCP/514
Ensure only Cluster 1 is configured to meet these requirements.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to configure syslog for Cluster 1.
1. Access Cluster 1 Prism Element
Since the requirement is to only configure Cluster 1 and not other clusters, this task must be performed in the Prism Element (PE) interface for Cluster 1.
* From the main Prism Central dashboard, navigate to Hardware > Clusters.
* Find Cluster 1 in the list and click its name. This will open the specific Prism Element login page for that cluster.
* Log in to Cluster 1's Prism Element interface.
2. Add the Syslog Server
* In the Cluster 1 PE interface, click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Syslog.
* In the "Remote Syslog Server" section, click the + Add Syslog Server button.
* Fill in the server details as required:
* Name: Corp_Syslog
* IP Address: 34.142.155.231
* Port: 514
* Protocol: TCP (This provides the highest reliability, as requested).
* Click Save.
3. Configure Log Modules and Severities
Now, we must specify which logs to send to the new server.
* On the same Syslog settings page, find the "Syslog Configuration" section and click the Configure button (or Modify if a default is present).
* A dialog box "Select Modules and Levels" will appear.
* Uncheck all modules to ensure no extra logs are sent.
* Check the box for the RSyslog Server Module (or rsyslog_forwarder).
* For this module, check the boxes for the severities: Critical, Warning, and Info.
* Check the box for the ApiServer module.
* This module logs all operational tasks and audit trails, which includes all Virtual Machine changes.
* For this module, check the boxes for the top severity levels: Critical, Warning, and Info.
* Ensure no other modules (like Stargate, Cerebro, Zookeeper, etc.) are checked.
* Click Save.
Cluster 1 is now configured to send its audit logs (including VM changes) and its own syslog monitoring logs to the Corp_Syslog server via TCP, fulfilling all security requirements.
Topic 2, Performance Based Questions Set 2
Environment
You have been provisioned a dedicated environment for your assessment which includes the following:
Workstation
* windows Server 2019
* All software/tools/etc to perform the required tasks
* Nutanix Documentation and whitepapers can be found in desktop\files\Documentation
* Note that the workstation is the system you are currently togged into Nutanix Cluster
* There are three clusters provided. The connection information for the relevant cluster will be displayed to the high of the question Please make sure you are working on the correct cluster for each item Please ignore any licensing violations
* Cluster A is a 3-node cluster with Prism Central 2022.6 where most questions will be performed
* Cluster B is a one-node cluster and has one syslog item and one security item to perform
* Cluster D is a one-node duster with Prism Central 5.17 and has a security policy item to perform Important Notes
* If the text is too small and hard to read, or you cannot see an of the GUI. you can increase/decrease the zoom of the browser with CTRL + ,and CTRL + (the plus and minus keys) You will be given 3 hours to complete the scenarios for Nutanix NCMMCI Once you click the start button below, you will be provided with:
- A Windows desktop A browser page with the scenarios and credentials (Desktop\instructions) Notes for this exam delivery:
The browser can be scaled lo Improve visibility and fit all the content on the screen.
- Copy and paste hot-keys will not work Use your mouse for copy and paste.
- The Notes and Feedback tabs for each scenario are to leave notes for yourself or feedback for
- Make sure you are performing tasks on the correct components.
- Changing security or network settings on the wrong component may result in a falling grade.
- Do not change credentials on an component unless you are instructed to.
- All necessary documentation is contained in the Desktop\Files\Documentation directory
NEW QUESTION # 22
TASK 1
A newly created Windows VM "SQL02" is experiencing poor storage performance when compared to
"SQL01" running within the same cluster, on the same storage container.
The cluster is in a healthy state.
Create a new session named Monitor SQL02 with meaningful metrics. Right click on the session page and click Select All then paste this into Notepad and save it as Task 1.txt on the desktop.
Also, save the analysis as a report named MonitorSQL02 and send the report as a PDF on a daily basis to perf_group@ACME.org. Reports should not be retained. If any new objects need to be created, use monitovm2 in the name.
Finally, correct the issue within "SQL02".
Notes:
* Do not power on the VMs.
* While you will be creating a session, you will need to examine the VM configurations to determine the issue.
* Do not delete the VM to resolve the issue, any other destructive change is acceptable.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to all three tasks, performed within the Nutanix Prism interface.
Task 1: Create Monitoring Session & Save Metrics
* From the Prism Central dashboard, navigate to Operations > Analysis.
* Click the + New Session button.
* Name the session Monitor SQL02.
* In the "Entities" search box, type SQL01 and select VM: SQL01.
* In the "Entities" search box, type SQL02 and select VM: SQL02.
* Click Add Charts > New Chart.
* Title: Storage IOPS
* Metric: Storage Controller IOPS
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Latency
* Metric: Storage Controller Latency
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Bandwidth
* Metric: Storage Controller Bandwidth
* Click Add.
* Click Save Session.
* With the "Monitor SQL02" session open, right-click anywhere on the page and click Select All.
* Right-click again and select Copy.
* Open Notepad, paste the content, and save the file to the desktop as Task 1.txt.
(The content pasted into Task 1.txt would be the session's chart configurations, showing metrics for SQL01 and SQL02.)
Task 2: Create and Schedule the Report
* While still in the "Monitor SQL02" analysis session, click the Save as Report button (it looks like a bookmark icon).
* Name the report MonitorSQL02 and click Save.
* Navigate to Operations > Reports.
* Find the MonitorSQL02 report in the list. Select its checkbox.
* Click the Actions dropdown and select Schedule.
* Configure the schedule with the following settings:
* Schedule Name: monitovm2_daily_report
* Recurrence: Daily
* Start Time: (Set to a time, e.g., 8:00 AM)
* Repeat every: 1 day(s)
* Retention Policy: Uncheck the "Retain a copy of the report" box. (This ensures reports are not retained).
* Email Report: Check this box.
* Format: PDF
* Recipients: perf_group@ACME.org
* Click Save.
Task 3: Identify and Correct the Performance Issue
This task is performed without powering on the VMs, indicating a configuration error.
Investigation
* Navigate to VMs > Table view.
* Click on the SQL01 (the good VM) and select the Configuration tab.
* Expand the Disks section. Observe that the primary disk is attached to a SCSI bus (e.g., scsi.0). This is the high-performance standard.
* Return to the VM list and click on SQL02 (the problem VM).
* Expand the Disks section.
Root Cause
You discover that the primary disk for SQL02 is attached to an IDE bus. The IDE bus has significant performance limitations and is not suitable for a database server, causing the poor storage performance.
Correction
* With the SQL02 VM selected, click the Update button.
* In the "Update VM" dialog, scroll down to the Disks section.
* Find the disk attached to the IDE bus. Click the Edit (pencil) icon for that disk.
* Change the Bus Type dropdown from IDE to SCSI.
* The Device Index will automatically populate (e.g., scsi.0).
* Click Save in the "Update Disk" dialog.
* (Note: A "VirtIO SCSI Controller" will be automatically added to the VM configuration if one was not already present.)
* Click Save in the "Update VM" dialog.
The VM SQL02 is now configured to use the high-performance VirtIO-SCSI controller, which will resolve the storage performance discrepancy once the VM is powered on.
NEW QUESTION # 23
Task 13
An administrator found a CentOS VM, Cent_Down, on the cluster with a corrupted network stack. To correct the issue, the VM will need to be restored from a previous snapshot to become reachable on the network again.
VM credentials:
Username: root
Password: nutanix/4u
Restore the VM and ensure it is reachable on the network by pinging 172.31.0.1 from the VM.
Power off the VM before proceeding.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
To restore the VM and ensure it is reachable on the network, you can follow these steps:
Log in to the Web Console of the cluster where the VM is running.
Click on Virtual Machines on the left menu and find Cent_Down from the list. Click on the power icon to power off the VM.
Click on the snapshot icon next to the power icon to open the Snapshot Management window.
Select a snapshot from the list that was taken before the network stack was corrupted. You can use the date and time information to choose a suitable snapshot.
Click on Restore VM and confirm the action in the dialog box. Wait for the restore process to complete.
Click on the power icon again to power on the VM.
Log in to the VM using SSH or console with the username and password provided.
Run the command ping 172.31.0.1 to verify that the VM is reachable on the network. You should see a reply from the destination IP address.
Go to VMS from the prism central gui
Select the VMand go to More -> Guest Shutdown
Go to Snapshots tab and revert to latest snapshot available
power on vm and verify if ping is working
NEW QUESTION # 24
Task 3
An administrator needs to create a report named VMs_Power_State that lists the VMs in the cluster and their basic details including the power state for the last month.
No other entities should be included in the report.
The report should run monthly and should send an email to admin@syberdyne.net when it runs.
Generate an instance of the report named VMs_Power_State as a CSV and save the zip file as Desktop\Files\VMs_Power_state.zip Note: Make sure the report and zip file are named correctly. The SMTP server will not be configured.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
To create a report named VMs_Power_State that lists the VMs in the cluster and their basic details including the power state for the last month, you can follow these steps:
Log in to Prism Central and click on Entities on the left menu.
Select Virtual Machines from the drop-down menu and click on Create Report.
Enter VMs_Power_State as the report name and a description if required. Click Next.
Under the Custom Views section, select Data Table. Click Next.
Under the Entity Type option, select VM. Click Next.
Under the Custom Columns option, add the following variables: Name, Cluster Name, vCPUs, Memory, Power State. Click Next.
Under the Time Period option, select Last Month. Click Next.
Under the Report Settings option, select Monthly from the Schedule drop-down menu. Enter admin@syberdyne.net as the Email Recipient. Select CSV as the Report Output Format. Click Next.
Review the report details and click Finish.
To generate an instance of the report named VMs_Power_State as a CSV and save the zip file as Desktop\Files\VMs_Power_state.zip, you can follow these steps:
Log in to Prism Central and click on Operations on the left menu.
Select Reports from the drop-down menu and find the VMs_Power_State report from the list. Click on Run Now.
Wait for the report to be generated and click on Download Report. Save the file as Desktop\Files\VMs_Power_state.zip.
1.Open the Report section on Prism Central (Operations > Reports)
2.Click on the New Report button to start the creation of your custom report
3.Under the Custom Views section, select Data Table
4.Provide a title to your custom report, as well as a description if required.
5.Under the Entity Type option, select VM
6.This report can include all as well as a selection of the VMs
7.Click on the Custom Columns option and add the below variables:
a.Name - Name of the listed Virtual Machine
b.vCPUs - A combination of the vCores and vCPU's assigned to the Virtual Machine c.Memory - Amount of memory assigned to the Virtual Machine d.Disk Capacity - The total amount of assigned virtual disk capacity e.Disk Usage - The total used virtual disk capacity f.Snapshot Usage - The total amount of capacity used by snapshots (Excluding Protection Domain snapshots)
8.Under the Aggregation option for Memory and Disk Usage accept the default Average option
9.Click on the Add button to add this custom selection to your report
10.Next click on the Save and Run Now button on the bottom right of the screen
11.Provide the relevant details on this screen for your custom report:
12.You can leave the Time Period For Report variable at the default of Last 24 Hours
13.Specify a report output of preference (PDF or CSV) and if required Additional Recipients for this report to be mailed to. The report can also simply be downloaded after this creation and initial run if required
14.Below is an example of this report in a CSV format:
NEW QUESTION # 25
......
Our services before, during and after the clients use our NCM-MCI-6.10 certification material are considerate. Before the purchase, the clients can download and try out our NCM-MCI-6.10 learning file freely. During the clients use our products they can contact our online customer service staff to consult the problems about our products. Our company gives priority to the satisfaction degree of the clients on our NCM-MCI-6.10 Exam Questions and puts the quality of the service in the first place. We also have free demo of our NCM-MCI-6.10 learning guide for you to check the quality before your payment.
NCM-MCI-6.10 New Dumps Pdf: https://www.examboosts.com/Nutanix/NCM-MCI-6.10-practice-exam-dumps.html
What's more, part of that ExamBoosts NCM-MCI-6.10 dumps now are free: https://drive.google.com/open?id=12r3ei6rkEF8q30w8dMRc5N9smuoBVxhk