Web-based TS-C practice test of TroytecDumps is accessible from any place. You merely need an active internet connection to take this NCCT TS-C practice exam. Browsers including MS Edge, Internet Explorer, Safari, Opera, Chrome, and Firefox support this TS-C Practice Exam. Additionally, this Tech in Surgery - Certified (NCCT), TS-C (NCCT) (TS-C) test is supported by operating systems including Android, Mac, iOS, Windows, and Linux.
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: End of Procedure Tasks and Postoperative Care | 16% | - End of Procedure Tasks
|
| Topic 2: Preoperative Care and Preparation | 32% | - Patient Safety
|
| Topic 3: Intraoperative Care and Preparation | 24.7% | - Preparation of Supplies
|
| Topic 4: Perioperative Care and Preparation | 27.3% | - Integrity and Sterility of Items
|
Our NCCT TS-C test braindump materials is popular based on that too. As we all know the passing rate for exams is low, the wise choice for candidates will select valid NCCT TS-C test braindump materials to make you pass exam surely and fast. Our NCCT TS-C test simulations will help you twice the result with half the effort.
NEW QUESTION # 130
Which of the following devices removes debris from surgical instruments through a process called cavitation?
Answer: A
Explanation:
An ultrasonic cleaner uses high-frequency sound waves to create microscopic cavitation bubbles within a cleaning solution. These bubbles rapidly form and collapse, producing localized mechanical forces that loosen and dislodge contaminants from surgical instrument surfaces.
Cavitation is particularly effective for cleaning difficult-to-reach areas, including instrument serrations, hinges, joints, and certain recessed surfaces.
During ultrasonic cleaning, instruments are submerged in an appropriate cleaning solution. Acoustic energy generates microscopic bubbles that implode near contaminated surfaces, assisting in the removal of blood, tissue debris, and other organic residues.
The CDC identifies cavitation and bubble implosion as the fundamental cleaning mechanisms of ultrasonic equipment.
CDC
Option A is incorrect because a washer-disinfector primarily relies on mechanical spray action, detergent chemistry, and thermal disinfection.
Option C is incorrect because STERIS is a manufacturer of medical reprocessing equipment rather than a specific cavitation-based cleaning mechanism.
Option D is incorrect because washer-sterilizers use automated washing and sterilization processes rather than ultrasonic cavitation as their defining function.
The surgical technologist must ensure that contaminated instruments receive appropriate point-of-use treatment before transport to the Sterile Processing Department.
Ultrasonic cleaning is not itself sterilization. Instruments must undergo the remaining validated cleaning, inspection, disinfection, or sterilization steps before reuse.
References:
NCCT TS-C Detailed Test Plan - Perioperative Care and Preparation; Instrument Sterilization; Decontamination; Microbiology.
CDC - Cleaning Reusable Medical Devices: Ultrasonic Cavitation .
CDC - Sterilizing Practices and Instrument Preparation .
NEW QUESTION # 131
After removal of the gallbladder, the surgeon indicates that they would like to place a drain into the common bile duct. Which of the following drains is appropriate?
Answer: D
Explanation:
The T-tube is a specialized biliary drainage device designed for placement within the common bile duct (CBD), particularly following surgical exploration of the duct or choledochotomy.
Its configuration consists of a transverse segment positioned within the common bile duct and a longitudinal segment that exits through the abdominal wall. The transverse portion helps maintain its position within the biliary system, while the external limb permits controlled drainage of bile.
T-tube drainage may be indicated following common bile duct exploration when the surgeon determines that temporary biliary decompression is necessary. The device provides an external route for bile drainage and may allow postoperative cholangiography to evaluate ductal patency, retained calculi, or potential leakage.
The Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) identifies T-tube placement as one possible method of managing a choledochotomy following common bile duct exploration.
A SAGES Publication
Option A is incorrect because a Penrose drain provides passive drainage from a wound or surgical space rather than controlled intraductal biliary drainage.
Options C and D are incorrect because Hemovac and Jackson-Pratt drains are closed-suction systems commonly used to evacuate fluid from operative spaces.
T-tubes are not routinely placed after uncomplicated cholecystectomy. Their use depends on the presence of biliary pathology, duct exploration, and the surgeon ' s clinical assessment.
References:
NCCT TS-C Detailed Test Plan - Intraoperative Care and Preparation; Preparation of Supplies, Section 3A3:
Surgical Drains, Catheters, and Tubing.
SAGES - Clinical Spotlight Review: Management of Choledocholithiasis .
NCBI Bookshelf - T-Tube .
NEW QUESTION # 132
Which of the following is the MOST common scope used during genitourinary surgery?
Answer: A
Explanation:
The cystoscope is one of the most commonly used endoscopic instruments in genitourinary surgery because it permits direct visualization of the urethra, urinary bladder, and associated anatomical structures.
Cystoscopy is performed for diagnostic and therapeutic purposes, including evaluation of hematuria, bladder tumors, urethral abnormalities, urinary obstruction, and recurrent urinary tract conditions.
Cystoscopes are available in rigid and flexible configurations. Rigid cystoscopes commonly consist of a telescope, sheath, obturator, bridge, and irrigation components. Flexible cystoscopes provide greater maneuverability and are frequently used during outpatient diagnostic procedures.
The NCBI Bookshelf identifies cystourethroscopy as one of the most frequently performed procedures in urologic practice.
NCBI
Option A is incorrect because a surgical microscope provides magnification during selected procedures but is not a genitourinary endoscope.
Option B is incorrect as the best answer because laparoscopes are used for minimally invasive abdominal and pelvic procedures across several specialties.
Option D is incorrect because an arthroscope is designed for visualization and treatment of joint structures.
The surgical technologist must ensure that the appropriate cystoscope, light source, camera, irrigation equipment, and specialized accessories are available and functioning correctly.
References:
NCCT TS-C Detailed Test Plan - Intraoperative Care and Preparation; Surgical Instrumentation; Endoscopic Equipment; Genitourinary Procedures.
NCBI Bookshelf - Cystoscopy .
Urologic Surgery - Endoscopic Instrumentation and Equipment .
NEW QUESTION # 133
What is the standard flash sterilization cycle for an instrument containing a lumen?
Answer: D
Explanation:
The intended examination answer is 4 minutes at 270°F (132°C), followed by a 1-minute drying or exhaust phase , corresponding to a commonly described prevacuum immediate-use steam sterilization cycle.
Instruments containing lumens present additional sterilization challenges because air may remain trapped within internal channels, preventing adequate steam penetration. Dynamic-air-removal sterilizers use vacuum- assisted conditioning to improve air removal and facilitate contact between saturated steam and internal surfaces.
The CDC ' s sterilization guidance identifies a four-minute exposure at 270°F for lumened instruments processed in an appropriate prevacuum cycle. STERIS additionally describes a one-minute drying phase during the exhaust portion of certain prevacuum immediate-use cycles.
CDC+1
Option A specifies the correct exposure time and temperature but omits the one-minute phase included in the examination ' s expected cycle description.
Options C and D are incorrect because three-minute cycles at 270°F are conventionally associated with appropriate nonporous, nonlumened instruments.
Important technical distinction: The one-minute drying phase is not a universal requirement for all sterilizers or lumened instruments. CDC guidance specifies 10 minutes at 270°F for comparable lumened loads in gravity-displacement sterilizers . Processing must follow the validated instructions for the instrument, sterilizer, and containment system.
Immediate-use steam sterilization should not replace routine sterilization merely for convenience.
References:
NCCT TS-C Detailed Test Plan - Perioperative Care and Preparation; Sterilization Methods; Instrument Processing; Sterilization Monitoring.
CDC - Table 8: Examples of Flash Steam Sterilization Parameters .
STERIS - Immediate-Use Steam Sterilization Cycles and Monitoring .
NEW QUESTION # 134
The circulating nurse accidentally leans on the sterile back table with their hand before the surgical procedure begins. What should be done NEXT?
Answer: D
Explanation:
The appropriate action is to break down the contaminated sterile setup and establish a new sterile field .
When an unsterile individual touches the prepared sterile back table, the affected area is considered contaminated, compromising the integrity of the surgical environment.
The circulating nurse is not scrubbed, gowned, and gloved as a sterile member of the surgical team.
Consequently, direct contact between the nurse ' s unsterile hand and the prepared sterile field introduces potential microbial contamination.
The Association of periOperative Registered Nurses (AORN) recommends removing compromised instruments and supplies and reestablishing the sterile field when significant contamination is identified before surgery begins.
Aorn.org
Option A is incorrect because simply avoiding the affected area does not reliably address contamination of the prepared table.
Option B is incorrect because the contamination must be addressed immediately according to established aseptic protocols rather than waiting for the surgeon to determine whether sterile technique should be maintained.
Option C is incorrect because covering an already contaminated surface with another sterile towel does not restore the underlying sterile barrier.
The surgical technologist should promptly communicate the contamination, remove affected supplies and draping, and prepare replacement sterile materials. A new sterile setup must be verified before the procedure proceeds.
References: NCCT TS-C Detailed Test Plan - Preoperative Care and Preparation, Section 2C1: Apply Principles of Aseptic Technique; Section 2C6: Recognize and Respond to Breaks in Sterile Technique.
Supporting professional standard: AORN - Dealing with Instrument Contamination and Speaking Up .
NEW QUESTION # 135
......
Our team of professionals and experts has prepared TS-C vce dumps by keeping the vigilant eyes on the current exam information and exam requirements. In case you failed exam with our TS-C study guide we will get you 100% money back guarantee and you can contact our support if you have any questions about our TS-C Real Dumps. We will be your support when you need us anytime.
TS-C Reliable Exam Registration: https://www.troytecdumps.com/TS-C-troytec-exam-dumps.html