P.S. Free & New H20-923_V1.0 dumps are available on Google Drive shared by ExamPrepAway: https://drive.google.com/open?id=1t6QmYp3gwnvndatdEdApDVjsVo94jf9x
We provide top quality verified Huawei certifications preparation material for all the H20-923_V1.0 exams. Our H20-923_V1.0 certified experts have curated questions and answers that will be asked in the real exam, and we provide money back guarantee on ExamPrepAway Huawei preparation material. Moreover, we also offer H20-923_V1.0 practice software that will help you assess your skills before real H20-923_V1.0 exams. Here is exclusive Huawei bundle deal, you can get all H20-923_V1.0 exam brain dumps now at discounted price.
| Certification Vendor: | Huawei |
|---|---|
| Exam Name: | HCSP-Field-Data Center Facility V1.0 |
| Exam Number: | H20-923_V1.0 |
| Related Certifications: | HCSP-Field-Data Center Facility (Power) V1.0 HCSP-Field-Data Center Facility (Modular DC) V1.0 |
| Exam Format: | Multiple-answer questions, Single-answer questions, True/False questions |
| Available Languages: | English |
| Certificate Validity Period: | 3 years |
| Real Exam Qty: | 60 |
| Passing Score: | 600 out of 1000 |
| Exam Price: | 100 USD |
| Exam Duration: | 90 minutes |
| Recommended Training: | Huawei Official Training |
| Exam Registration: | Pearson VUE Registration |
| Sample Questions: | Huawei H20-923_V1.0 Sample Questions |
| Exam Way: | Online proctored or onsite at Pearson VUE test centers |
| Pre Condition: | Basic knowledge of data center infrastructure, power and cooling systems; recommended to have HCIA-Data Center Facility certification or equivalent experience |
| Official Syllabus URL: | https://e.huawei.com/en/talent/cert/#/specialistCert |
>> H20-923_V1.0 Valid Exam Fee <<
We hold coherent direction with our exam candidates, so our H20-923_V1.0 study materials are compiled in modern format. Many competitors simulate and strive to emulate our standard, but our H20-923_V1.0 training branindumps outstrip others in many aspects, so it is incumbent on us to offer help. Considering the current plea of our exam candidates we make up our mind to fight for your satisfaction and wish to pass the H20-923_V1.0 Exam.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
| Topic 7 |
|
| Topic 8 |
|
| Topic 9 |
|
| Topic 10 |
|
| Topic 11 |
|
| Topic 12 |
|
| Topic 13 |
|
| Topic 14 |
|
| Topic 15 |
|
| Topic 16 |
|
NEW QUESTION # 36
Why does Huawei's O&M guidance emphasize completing startup password authentication before allowing any commissioning actions on a smart module?
Answer: A
Explanation:
Completing startup authentication (e.g., initial password setup) hardens the management plane before any commissioning or configuration actions are permitted, closing the security gap that could otherwise exist if default or incomplete credentials allowed unauthorized access during initial deployment.
NEW QUESTION # 37
The NetEco service program backend can be accessed through the iBMC port.
Answer: A
Explanation:
In Huawei data center facility management,NetEcois the management software platform (server/application) used to centrally monitor and manage sites, whileiBMCis the out-of-band hardware management interface used forserver remote maintenance(such as power control, hardware health, BIOS settings, and remote console) on the specific server where iBMC exists. TheiBMC port is not a service access interface for NetEco. NetEco's backend services are accessed through theserver operating system network interfaces (management/service network) and corresponding application ports after the server is properly networked and configured. Even if NetEco is deployed on a Huawei server that has iBMC, iBMC only provides a channel to manage the server hardware and does not expose NetEco application access as an official commissioning
/O&M path. Therefore, NetEco backend access should be planned via the site's management network (IP addressing, routing, security policy), not via iBMC.
NEW QUESTION # 38
On the ECC800-Pro WebUI, the PUE configuration mode can be "Standard" or "User-defined".
Answer: B
Explanation:
Huawei's ECC800-Pro supports PUE (Power Usage Effectiveness) management as part of its energy efficiency and green data center features. In practical O&M, different sites calculate PUE differently depending on metering topology, what loads are included (IT load only vs. auxiliary loads), and whether the site uses integrated modules (UPS, cooling, lighting, etc.) or external systems. To handle these real-world differences, the ECC800-Pro provides two PUE configuration approaches on the WebUI."Standard"mode is used when the site's metering points and calculation logic align with a predefined Huawei template, enabling rapid commissioning and consistent reporting."User-defined"mode is used when the customer's metering structure or management requirements differ-allowing engineers to select specific measurement points, define inclusion/exclusion rules, and tailor the calculation path so that displayed PUE matches the site's accepted KPI definition. This dual-mode design ensures PUE is both standardized where possible and flexible where necessary, improving energy analysis accuracy and supporting optimization actions.
NEW QUESTION # 39
If the startup password authentication for a smart module is not complete, the ECC800-Pro WebUI and app cannot be used for commissioning.
Answer: B
Explanation:
In Huawei smart module commissioning and O&M workflows,startup password authentication is a mandatory security initialization stepfor the controller and its management channels. The ECC800-Pro provides WebUI and mobile app access for tasks such as device discovery, parameter setting, site configuration, alarm verification, and functional commissioning. Before these commissioning functions are allowed, the system requires completion of startup authentication actions, typically includinginitial password setup or password change, confirmation of authentication policies, and activation of secure access control. This prevents unauthorized users from entering the management plane during the critical initial stage when default credentials or incomplete security settings could exist. If startup password authentication is not completed, the platform restricts access to commissioning pages and app-based commissioning features, ensuring that configuration changes, device binding, and control operations cannot be executed until the controller is placed into a compliant, secured state. This design aligns with data center facility management best practices where commissioning must begin only after management access is hardened and auditable.
NEW QUESTION # 40
Video management can connect to the third-party video surveillance subsystem and play historical videos.
Answer: B
Explanation:
In Huawei's data center O&M architecture, video is treated as an important auxiliary capability for security and remote operation. TheVideo Managementfunction is designed not only to view live camera feeds, but also to integrate video resources into the same O&M workflow as alarms, access control events, and environmental monitoring. In typical deployments, the actual video storage and recording are handled by athird-party video surveillance subsystem(for example, an NVR/VMS platform). Huawei's video management function can connect to that third-party subsystem so that camera resources can be accessed in a unified interface, allowing operators to perform linkage operations such as "view video on alarm" and routine security inspection without switching platforms. Because historical recordings are stored by the surveillance subsystem, once the integration is established and permissions are correctly configured, operators can retrieve andplay back historical videofor event tracing, audit, and incident investigation. This supports closed-loop O&M: alarm/event occurs # video verification # root-cause confirmation # maintenance action # evidence retention.