| Section | Objectives |
|---|---|
| Topic 1: Code Compliance and Related Requirements | - Energy code requirements applicable to mass timber buildings - Sound transmission requirements - Documentation and verification of compliance |
| Topic 2: Fire Protection and Fire-Resistance | - Noncombustible protection and protection of mass timber elements - Fire protection systems and related provisions - Fire-resistance requirements |
| Topic 3: Construction Fire Safety | - Construction-phase fire safety requirements - International Fire Code requirements - Protection of mass timber during construction |
| Topic 4: Tall Mass Timber Building Code Provisions | - Mass timber materials and construction requirements - Types IV-A, IV-B and IV-C construction - International Building Code requirements for tall mass timber construction |
| Topic 5: Structural Inspection | - Mass timber structural elements - Structural loads and related code requirements - Connections and fastening systems |
| Topic 6: Special Inspection Requirements | - Inspection of connections and protective materials - Special inspection procedures for tall mass timber buildings - Inspector duties and responsibilities |
>> 93-Tall-Mass-Timber-Buildings考試內容 <<
Fast2test長年以來一直向大家提供與International Code Council認證考試相關的93-Tall-Mass-Timber-Buildings參考資料。這是一個被廣大考生檢驗過的網站,可以向大家提供最好的考試考古題。Fast2test全面保證考生們的利益,得到了大家的一致好評。而且,Fast2test也是當前市場上最值得你信賴的網站。
問題 #79
In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:
答案:C
解題說明:
A 7/16-inch wood structural panel does not satisfy the prescribed minimum thickness for fireblocking.
Therefore, option C is the exception.
IBC Section 718.2.1 permits one thickness of 23/32-inch wood structural panel where the joints are properly backed. A 7/16-inch panel is substantially thinner and cannot be substituted without an approved alternative- material determination. The code also recognizes one-half-inch gypsum board and properly installed batts or blankets of mineral wool or other approved materials.
Mass timber complying with Section 2304.11 is also permitted as fireblocking. Its large cross section provides resistance to the movement of flame, hot gases, and smoke through a concealed space that is at least equivalent to the nominal lumber traditionally accepted for this purpose.
The inspector must distinguish fireblocking from a tested firestop system. Fireblocking divides or interrupts concealed combustible cavities; it does not automatically protect a penetration through a fire-resistance-rated wall or floor. Installation must completely fill or close the required space, remain securely supported, and comply with requirements for joints, edges, penetrations, and mineral-fiber compression.
References/Topics: 2021 IBC Section 718.2.1; Section 2304.11; approved fireblocking materials in mass timber construction.
問題 #80
Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown, which fasteners require fire protection according to AWC Technical Report 10?
答案:B
解題說明:
The 1/2-inch lag screws attaching the structural steel ledger require fire protection, making option D correct. These fasteners are structural components of the ledger-to-CLT connection and therefore form part of the connection whose fire performance must be maintained for the required duration.
AWC Technical Report 10 states that wood structural connections-including their connectors, fasteners, and participating members-must be protected from fire exposure for the required fire-resistance time
. Protection may be provided by wood cover, fire-rated gypsum board, other approved materials, or a combination.
TR10 distinguishes structural connection fasteners from small fasteners used merely to hold sacrificial protection in place. The report specifically explains that fasteners attaching protective wood strips need not themselves be protected, provided they are sufficiently long to keep the protection in position throughout the required exposure.
In the illustrated ledger connection, the 1/2-inch lag screws transfer structural load between the steel ledger and CLT wall. Their thermal protection is therefore integral to maintaining connection capacity.
References/Topics: AWC Technical Report No. 10 Sections 4.5 and connection examples; thermal protection of structural connectors and fasteners.
問題 #81
For Type IV-A construction, noncombustible protection shall provide what fraction of the required fire- resistance rating for building elements?
答案:A
解題說明:
The prescribed proportion is two-thirds , making option C correct. The relationship is demonstrated directly by IBC Table 722.7.1(1). A building element requiring a one-hour fire-resistance rating must receive 40 minutes of noncombustible protection; a two-hour element requires 80 minutes; and a three-hour-or-greater element requires 120 minutes. Each of those prescribed values represents two-thirds of the corresponding one-
, two-, or three-hour rating.
For Type IV-A specifically, Section 602.4.1.2 requires protection of the interior faces of all mass timber elements. Section 602.4.1.2.1 further states that the protection must contribute at least the time assigned in Table 722.7.1(1) and not less than 80 minutes .
The remaining portion of the required fire resistance is provided by the mass timber element itself. Thus, for a three-hour Type IV-A primary structural element, 120 minutes are provided through noncombustible protection and the timber must supply the remaining required endurance.
This two-component approach is fundamental to the Type IV-A fire-design methodology.
References/Topics: 2021 IBC Sections 602.4.1.2 and 602.4.1.2.1; Tables 601 and 722.7.1(1); protected Type IV-A mass timber.
問題 #82
According to UL Fire Resistance Directory, a "finish rating" is the time:
答案:D
解題說明:
Option C correctly states the fundamental UL finish-rating criterion. UL defines a finish rating for assemblies containing combustible wood structural supports as the elapsed fire-exposure time at which the wood member immediately behind the protective membrane reaches the prescribed temperature-rise threshold.
More precisely, UL uses two criteria: an average temperature rise of 250°F or an individual-point temperature rise of 325°F , measured on the plane of the wood nearest the fire, typically between the gypsum membrane and the wood stud or joist. The question asks for the principal definition, which is the 250° F temperature-rise criterion; therefore, option C is correct. Option D incorrectly treats the 325°F individual- point limit as the sole definition.
Options A and B confuse a finish rating with "assigned protection time." IBC Tables 722.6 and 722.7 provide calculated contribution values for specified protective materials, but those assigned values are not themselves UL finish ratings.
This distinction matters in mass timber fire design because membrane contribution, thermal separation, structural fire resistance, and finish rating are related but not interchangeable concepts.
References/Topics: UL Fire Resistance Directory terminology; finish rating; average 250°F and individual
325°F temperature-rise criteria.
問題 #83
Refer to the exhibit by clicking on the EXHIBIT button above.
In the detail shown, the 2x2 block is intended for what purpose according to AWC Technical Report 10?
答案:A
解題說明:
The 2 × 2 block is intended to protect the abutting wood edges from the effects of char contraction. Therefore, option D is correct.
During fire exposure, wood chars and the char layer can shrink or contract. At an interface between two abutting timber components, that contraction can create a gap that allows heat and flames to penetrate deeper than predicted for a continuous exposed surface. AWC connection-fire-design methodology therefore requires additional protection at susceptible joints and interfaces. The block shields the abutting edges and maintains the sacrificial wood-cover path around the protected connection.
Its primary function is not decorative, nor is it simply an air-sealing component. Although limiting airflow can be a secondary consequence of closing the interface, the design purpose addressed by the technical guidance is control of premature fire penetration caused by char contraction. The block also should not be interpreted independently as a generic one-hour protective membrane for the steel ledger; the connection's total rating depends on the complete approved protection assembly.
The inspector should confirm the block's dimensions, species or product designation, fastening, continuity, and tight installation before the connection is concealed.
References/Topics: AWC Technical Report 10; AWC Fire Design Specification provisions addressing char contraction and gaps between abutting wood members.
問題 #84
......
你用過Fast2test的93-Tall-Mass-Timber-Buildings考古題嗎?這個考古題是最近剛更新的資料,包括了真實考試中可能出現的所有問題,保證你一次就可以通過考試。這個考古題可以讓你看到你意想不到的成果。如果你考試失敗Fast2test將會全額退款,所以請放心使用。利用Fast2test的考試資料,你肯定可以得到你想要的成功。
93-Tall-Mass-Timber-Buildings熱門證照: https://tw.fast2test.com/93-Tall-Mass-Timber-Buildings-premium-file.html