試験の準備方法-権威のあるM2試験解説試験-素敵なM2模擬トレーリング

当社はJpshiken、世界中のM2試験トレントコンパイル部門の販売およびアフターサービスを提供する多国籍企業です。 さらに、当社はこの分野で一流の企業になりました。そのため、関連するM2認定を取得するために試験の準備をしている場合、当社がまとめたM2のInternational Code Council試験問題はあなたの堅実なものです。 選択。 当社の世界中のすべての従業員は、お客様がM2試験に合格するための電子的なM2試験トレントの最高のグローバルサプライヤになるという共通の使命の下でCommercial Mechanical Inspector運営されています。

International Code Council M2 Exam Syllabus Topics:

SectionObjectives
Duct Systems- Air Distribution
  • 1. Plenums
  • 2. Duct Insulation
- Duct Construction
  • 1. Materials and Installation
  • 2. Dampers and Protection
Ventilation and Exhaust Systems- Ventilation
  • 1. Mechanical Ventilation
  • 2. Exhaust Air Systems
- Commercial Kitchens
  • 1. Kitchen Exhaust Hoods
  • 2. Grease Ducts
Heating and Cooling Systems- Heating Appliances
  • 1. Water Heaters
  • 2. Furnaces
  • 3. Boilers
- Cooling Systems
  • 1. Cooling Appliances
  • 2. Refrigeration Equipment
Hydronic Piping and Refrigeration- Refrigeration
  • 1. Refrigerant Piping
  • 2. Safety Controls
- Hydronic Systems
  • 1. Pressure Testing
  • 2. Piping Installation
Combustion Air and Fuel Supply- Combustion Air
  • 1. Indoor and Outdoor Air Requirements
  • 2. Combustion Air Openings
- Fuel Supply Systems
  • 1. Fuel Gas Piping
  • 2. Fuel Oil Systems
General Administration- Code Scope and Administration
  • 1. Referenced Standards
  • 2. Permits and Inspections
  • 3. Definitions
Materials and Specifications- Approved Materials
  • 1. Installation Standards
  • 2. Equipment Labeling
Chimneys and Vents- Connectors and Terminations
  • 1. Termination Requirements
  • 2. Vent Connectors
- Vent Systems
  • 1. Vent Sizing
  • 2. Chimney Clearances

>> M2試験解説 <<

一番優秀International Code Council M2|高品質なM2試験解説試験|試験の準備方法Commercial Mechanical Inspector模擬トレーリング

International Code CouncilのM2試験問題には3つの異なるバージョン(PDF、ソフトウェア、APPオンライン)があるため、M2学習ガイドのバージョンには複数の選択肢があり、興味や習慣に応じて選択できます。 International Code CouncilソフトウェアまたはAPPオンラインバージョンのM2準備資料は、コンピューターまたは電話で練習できます。 それらは、エレクトロニクス製品が私たちの生活や仕事のスタイルに広く適用されているという理由で開発された新しいものです。 M2の実際のCommercial Mechanical Inspector試験のPDFバージョンは印刷をサポートしており、論文で練習してメモを取ることができます。

International Code Council Commercial Mechanical Inspector 認定 M2 試験問題 (Q17-Q22):

質問 # 17
All exposed gas piping shall be kept above grade a minimum of _____ inches.

正解:D

解説:
The IFGC rule for above-ground outdoor piping requires piping installed outdoors to be elevated not less than 3 1/2 inches above ground , and where installed across roof surfaces, not less than 3 1/2 inches above the roof surface . Therefore, the correct answer is A .


質問 # 18
Air mechanically exhausted from a room must be:

正解:D

解説:
The IMC requires air removed by a mechanical exhaust system to be discharged outdoors to an approved location and not be readily drawn back into the building. That makes D correct. The code does not permit general exhaust air to terminate in an attic, and it does not make filtering or recirculation the default rule for mechanically exhausted air.


質問 # 19
What is the minimum air velocity that must be provided by an exhaust duct system serving a Type I range hood?

正解:D

解説:
For commercial kitchen exhaust associated with Type I hood systems, the recognized code-based minimum duct transport velocity is 1,500 feet per minute , so C is the correct answer. Option B uses the wrong unit, and the other listed velocities do not match the code minimum used for this question type.


質問 # 20
The exhaust outlet for a clothes dryer is required to be equipped with:

正解:A

解説:
The IMC requires clothes dryer exhaust ducts to terminate outside the building and to be equipped with a backdraft damper at the terminal. The code also prohibits screens at dryer terminations because lint can accumulate and obstruct flow. That makes Option A correct and eliminates Option C . The other two choices describe controls not required by the dryer exhaust termination rule.


質問 # 21
Exhaust is required for which of the following areas?

正解:A

解説:
Under the IMC ventilation table, locker/dressing rooms and sports locker rooms are identified with required mechanical exhaust, while spaces such as guard stations do not carry that same exhaust requirement in the table. A high school locker room falls within the locker-room/sports-locker-room category, so Option C is the correct answer. Gambling casinos and office break rooms are provided outdoor air rates, but they are not the required-exhaust space among these listed choices.


質問 # 22
......

我々の目標はM2試験に準備するあなたに試験に合格させることです。この目標を実現するようには、我が社のJpshikenは試験改革のとともにめざましく推進していき、最も専門的なM2問題集をリリースしています。現時点で我々のInternational Code Council M2問題集を使用しているあなたは試験にうまくパースできると信じられます。心配なく我々の真題を利用してください。

M2模擬トレーリング: https://www.jpshiken.com/M2_shiken.html