BONUS!!! Download part of ExamTorrent VNX301 dumps for free: https://drive.google.com/open?id=1gvSKHBS15TmJ4_OTRhqw1d6-F1JEFocl
We continually improve the versions of our VNX301 exam guide so as to make them suit all learners with different learning levels and conditions. The clients can use the APP/Online test engine of our VNX301 exam guide in any electronic equipment such as the cellphones, laptops and tablet computers. Our after-sale service is very considerate and the clients can consult our online customer service about the price and functions of our VNX301 Quiz materials. So our VNX301 certification files are approximate to be perfect and will be a big pleasant surprise after the clients use them.
| Certification Vendor: | Versa Networks |
|---|---|
| Exam Name: | Versa Certified Administrator - SD-WAN Specialist |
| Exam Number: | VNX301 |
| Exam Price: | $150 USD |
| Real Exam Qty: | 60 |
| Certificate Validity Period: | 2 years |
| Exam Duration: | 90 minutes |
| Passing Score: | Not officially published |
| Exam Format: | Multiple Choice, Multiple Select |
| Available Languages: | English |
| Related Certifications: | Versa Certified SD-WAN Associate (VNX100) |
| Recommended Training: | Versa Advanced Services Training Versa Secure SD-WAN Configuration and Administration |
| Exam Registration: | Versa Academy Certification Page Kryterion Testing Services |
| Sample Questions: | Versa Networks VNX301 Sample Questions |
| Exam Way: | Online proctored or onsite testing center via Kryterion |
| Pre Condition: | Must hold Versa Certified SD-WAN Associate (VNX100); 1+ year hands-on experience recommended |
| Official Syllabus URL: | https://academy.versa-networks.com/certification-vnx300 |
>> VNX301 Reliable Dumps Ebook <<
Our VNX301 test questions are available in three versions, including PDF versions, PC versions, and APP online versions. And VNX301 test material users can choose according to their own preferences. The most popular version is the PDF version of VNX301 exam prep. The PDF version of VNX301 test questions can be printed out to facilitate your learning anytime, anywhere, as well as your own priorities. The PC version of VNX301 Exam Prep is for Windows users. If you use the APP online version, just download the application program, you can enjoy our VNX301 test material service.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
NEW QUESTION # 13
Examine the exhibit below.
You are configuring Class of Service on a WAN-facing network interface, and you want to perform DSCP rewrite on the packets that are forwarded to the WAN.
However, you are not able to turn on DSCP rewrite.
Referring to the exhibit, what is the cause of this issue?
Answer: B
Explanation:
In the exhibit, the Add Associate Interface/Network window has Interface selected, and the interface name is set to vni-0/0 . The DSCP rewrite option is not available because rewrite behavior is intended to be applied at the network association level for the WAN network, not directly while associating only the physical
/logical interface. For WAN-facing CoS, the scheduler and shaping parameters can be attached to an interface, but DSCP rewrite policies are applied to remark traffic as it exits through a network context.
Versa SD-WAN design documentation explains that QoS rewrite rules rewrite packet QoS attributes as packets leave the VOS device, and that rewrite rules can modify IEEE 802.1p bits, IPv4 TOS/DSCP bits, and IPv6 traffic class bits. It also explains that a rewrite policy is commonly applied on a WAN network to remark traffic based on the forwarding class and loss priority assigned by QoS or App QoS policies. In the design example, Versa explicitly describes applying a QoS propagation or rewrite policy on the MPLS WAN network to remark traffic to a DSCP value. Therefore, the issue is the association type: it is set to Interface, not Network.
NEW QUESTION # 14
What are three roles that VOS performs? (Choose three.)
Answer: B,C,D
Explanation:
The correct answers are A, B, and E . Versa Operating System, or VOS , is the software platform used for Versa SD-WAN branch and headend functions. Versa troubleshooting documentation explicitly refers to common runtime state across SD-WAN Controller, branch, and hub devices , confirming that VOS is used for Controller and branch-style SD-WAN roles. Versa monitoring documentation also lists SD-WAN branches, SD-WAN Controller nodes, SD-WAN hubs, vCPEs, and uCPEs as assets that are monitored and managed in Versa Director, which aligns with VOS being used as a branch/edge and controller platform.
VOS can also act as a uCPE platform . Versa documentation includes procedures to configure uCPE on a VOS device, showing that VOS can host or support uCPE deployment use cases.
The originally provided answer A, C, D is not correct. A Log Collector or log forwarder function belongs to the Versa Analytics architecture, not the VOS branch role; Versa's design guide states that the log forwarder is part of the Versa Analytics node or can run as a standalone log-forwarder server.
A Zookeeper arbiter is also not a standard VOS SD-WAN device role in this context.
NEW QUESTION # 15
You are troubleshooting a branch that cannot form SD-WAN overlay tunnels. The branch has WAN interfaces up, but you suspect remote endpoint objects were not learned. Which VSM command should you use to verify whether remote site objects were learned from BGP or from configuration?
Answer: B
Explanation:
The correct answer is A . Versa data-path troubleshooting documentation gives a specific VSM control-plane workflow for checking SD-WAN tunnel objects. After connecting to the VSM daemon, administrators can use show vsm p2mp local-tunnel-sites 0 to inspect local site objects. To check whether remote site objects were learned from BGP or from configuration , Versa instructs administrators to issue show vsm p2mp tunnel-remote-endpoint tenant < tenant-id > on the VSM control plane.
This command is highly relevant when local WAN interfaces are operational, but overlay tunnel formation is incomplete. It shows remote endpoints such as Controllers, hubs, or branches, along with site type, site name, branch ID, tenant ID, remote WAN link information, and tunnel state-related fields.
show interfaces brief confirms interface state and IP addresses, but it does not show learned remote SD- WAN endpoint objects. CGNAT summary is unrelated to tunnel endpoint learning. System storage is useful for disk checks, but not for SD-WAN overlay endpoint troubleshooting.
NEW QUESTION # 16
During branch onboarding, you need to verify whether the Controller has sent branch-connect and branch- disconnect notifications to Versa Director. Which CLI command should be used?
Answer: D
Explanation:
The correct answer is A . Versa troubleshooting documentation states that after a branch device successfully establishes an IPsec connection to the Controller node, the Controller sends a notification to the Director node. To display the details of this notification, the documentation instructs administrators to issue the show alarms CLI command. It also provides examples using show alarms | match branchd | match br101 to view branch-connect and branch-disconnect events.
These alarm entries are valuable during onboarding because they show whether the branch reached the Controller, whether staging progressed, and whether the branch later disconnected. For example, branch lifecycle notifications include factory-default connection, staged connection, Stage 3 connection with WAN IP addresses, and branch disconnect events.
show system storage is useful for disk usage, show interfaces detail helps with link state, speed, duplex, and interface counters, and show cgnat acl info is used for CGNAT matching. None of those commands directly confirms branch lifecycle notifications between Controller and Director.
NEW QUESTION # 17
A new SD-WAN branch has completed factory-default onboarding and Versa Director has pushed the staging configuration. After reboot, the branch still tries to connect to the staging server instead of the Controller.
Which configuration item is most likely incorrect or missing in the stage-two configuration?
Answer: C
Explanation:
The correct answer is A . During Versa SD-WAN onboarding, the branch uses the staging server only in the early part of the process. Versa documentation states that in Stage 1 , the branch starts an IKE session with the staging server, receives an IP address, and is informed of the Versa Director IP address. In Stage 2 , Versa Director pushes the stage-two configuration to the branch through the staging server. In this stage-two configuration, the Controller IP address is given as the remote IP address in the IPsec profile , and the branch is rebooted. After reboot, the branch should establish the IKE session with the Controller.
If the branch keeps trying to connect to the staging server after the stage-two reboot, the most likely issue is that the stage-two IPsec profile still points to the staging server or does not contain the correct Controller remote IP. Analytics, DHCP, and URL filtering settings do not determine whether the branch moves from staging-server connectivity to Controller IKE connectivity.
NEW QUESTION # 18
......
Exam Questions VNX301 Vce: https://www.examtorrent.com/VNX301-valid-vce-dumps.html
BONUS!!! Download part of ExamTorrent VNX301 dumps for free: https://drive.google.com/open?id=1gvSKHBS15TmJ4_OTRhqw1d6-F1JEFocl