問題 #86
The highest voltage rating on a piece of medium voltage equipment is the:
答案:A
解題說明:
The correct answer isA, basic impulse level. On medium voltage equipment, thebasic impulse level BILis the highest voltage-related rating normally associated with the insulation system. BIL represents the ability of the equipment insulation to withstand a specified high-voltage impulse, such as a lightning surge or switching surge, without failure. It is therefore a dielectric withstand rating that is higher than the equipment's normal operating or system voltage and is used to define insulation coordination for the equipment.
The other choices are not the best answer.Nominal voltageidentifies the intended system operating voltage class, but it is not the highest voltage-related rating.AC high potentialandDC high potentialare test voltages used during dielectric testing, not the principal nameplate rating that defines the equipment's insulation impulse withstand capability. In source inspection of switchgear and other medium voltage assemblies, the inspector verifies that the equipment ratings, including voltage class, insulation level, and test records, agree with the purchase specification and applicable standards.
Because BIL expresses the highest recognized insulation withstand rating among the listed options,Ais the verified answer.
問題 #87
A visual inspection includes verification of all the following except:
答案:C
解題說明:
The correct answer isDbecause aPoint-to-Point testis anelectrical continuity and functional verification test, not a visual inspection activity. In API source inspection and quality surveillance of electrical equipment, a visual inspection is concerned with what can be directly observed and compared against approved documentation, specifications, and fabrication requirements. This includes verifying that the equipment arrangement matches applicable drawings, checkingnameplate datafor correctness, confirming thatgrounding provisionsare present and properly installed, and ensuring the physical build appears consistent with design requirements.
APoint-to-Point test, by contrast, is performed to verify that wiring connections are electrically correct from one termination point to another. It is typically part of checkout, continuity verification, or functional testing rather than a simple visual examination. That is why options A, B, and C all fall within the scope of visual inspection, while D does not.
From a source inspector's standpoint, the distinction matters because visual checks confirm physical conformance, whereas point-to-point testing confirms circuit correctness and wiring integrity through an active test process.
問題 #88
In addition to maximum rated voltage, manufacturer's name, trademark and AWG, which of the following markings is required for all conductors and cables?
答案:C
問題 #89
According to the referenced API standard in the guide, special purpose induction motors covered by API STD
541 are:
答案:A
問題 #90
The insulation requirement referred to in NEMA ICS 1 defines clearance as the shortest distance:
答案:D
解題說明:
The correct answer isC. InNEMA ICS 1, the termclearancerefers to theshortest distance through air between two conductive parts. This is an important insulation concept used in industrial control and electrical equipment because adequate air spacing helps prevent dielectric breakdown, flashover, and unintended arcing when equipment operates at its rated voltage. During source inspection, this matters when verifying control panels, terminals, bus arrangements, relays, and other energized components where spacing must conform to design standards and applicable codes.
OptionBdescribes a different concept known ascreepage distance, which is the shortest pathalong the surface of an insulating materialbetween conductive parts. Clearance and creepage are related but not the same, and inspectors must understand that distinction when reviewing equipment construction. OptionAis not the NEMA definition of clearance, and optionDrefers more to personnel approach boundaries or electrical safety concepts, not insulation spacing requirements.
For API source inspection of control panels and similar assemblies, verifying properair clearancesis essential to confirming safe construction and compliance with specified electrical standards.
問題 #91
......
作為一位 API-SIEE 考生而言,作好充分的準備可以幫助您通過考試。Fast2test 的 API-SIEE 題庫覆蓋了最新的 API-SIEE 考試指南及考試真題題型。API-SIEE 隸屬于 API 認證考試科目。我們的 API-SIEE 認證考題已經幫助很多考生通過考試,試題質量和考題的覆蓋率都有保證,保證考生權利不受任何損失。獲取 API-SIEE 考試認證證書可以用來實施一些複雜多變的工程。