What's more, part of that DumpsReview FlashArray-Implementation-Specialist dumps now are free: https://drive.google.com/open?id=1flVSvoTYl9EaNp2JXn-NyeYE9uLiHBv4
More qualified certification for our future employment has the effect to be reckoned with, only to have enough qualification FlashArray-Implementation-Specialist certifications to prove their ability, can we get over rivals in the social competition. Many candidates be defeated by the difficulty of the FlashArray-Implementation-Specialist exam, but if you can know about our FlashArray-Implementation-Specialist Exam Materials, you will overcome the difficulty easily. If you want to buy our FlashArray-Implementation-Specialist exam questions please look at the features and the functions of our product on the web or try the free demo of our FlashArray-Implementation-Specialist exam questions.
| Certification Vendor: | Pure Storage |
|---|---|
| Exam Name: | Pure Storage Certified FlashArray Implementation Specialist |
| Exam Number: | FAIS |
| Exam Format: | Multiple Choice (three or four options, one to two correct answers) |
| Real Exam Qty: | 75 |
| Exam Price: | USD $300 |
| Related Certifications: | Pure Storage FlashArray Implementation Specialist Certification |
| Passing Score: | Not publicly disclosed by Pure Storage |
| Exam Duration: | 120 minutes |
| Certificate Validity Period: | 3 years |
| Available Languages: | English |
| Sample Questions: | Pure Storage FlashArray-Implementation-Specialist Sample Questions |
| Exam Way: | Online (proctored via examslocal.com) |
| Pre Condition: | Recommended hands-on experience with Pure Storage FlashArray systems. Targeted at internal Pure Storage Support Specialists, Partner Support Specialists with root level access, and Enterprise or Dark Site customers with root level access. |
| Official Syllabus URL: | https://academy.purestorage.com/student/page/2164533-certification-fais |
>> Exam FlashArray-Implementation-Specialist Tests <<
Our considerate service is not only reflected in the purchase process, but also reflected in the considerate after-sales assistance on our FlashArray-Implementation-Specialist exam questions. We will provide considerate after-sales service to every user who purchased our FlashArray-Implementation-Specialist practice materials. If you have any questions after you buy our FlashArray-Implementation-Specialist study guide, you can always get thoughtful support and help by email or online inquiry. If you neeed any support, and we are aways here to help you.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
NEW QUESTION # 118
An Implementation Engineer is installing the first DirectFlash Shelf (DFS) on a FlashArray//XR4 controller.
Which ports should the Implementation Engineer use for the connection?
Answer: C
Explanation:
The FlashArray//XR4 utilizes onboard 100GbE RoCE (RDMA over Converged Ethernet) ports for connecting to the first loop of DirectFlash Shelves, removing the need for dedicated PCIe add-in cards for the base configuration. The port mapping for these onboard backend ports differs from previous generations.
On the //XR4 controller chassis, the specific Ethernet interfaces designated for the first DirectFlash Shelf loop are typically the high-numbered onboard ports. In this specific exam context and hardware revision, ETH 18 and ETH 19 are identified as the correct primary backend connectivity ports .
Implementation Engineers must connect the QSFP28 cables from the "uplink" ports on the first shelf (IOM0 and IOM1) to ETH18 and ETH19 on the controllers (CT0 and CT1) respectively. Using incorrect ports (like ETH0/1, which are management) would result in the shelf not being detected by the storage fabric.
=========
NEW QUESTION # 119
Prior to installing a new FlashArray controller, which terminal display settings must the Implementation Engineer configure?
Answer: A
Explanation:
When unpacking and installing a new Pure Storage FlashArray controller, the initial configuration-such as assigning management IP addresses, subnet masks, and gateways via the puresetup utility-must be done completely out-of-band. Because the array does not yet have an IP presence on the customer's network, the Implementation Engineer must connect directly to the controller's serial console port using a standard serial-to- USB adapter and terminal emulation software (such as PuTTY, SecureCRT, or Tera Term).
To successfully establish a readable CLI session with the custom Linux microkernel running on the FlashArray controllers, the terminal emulator must be configured with the exact serial communication parameters expected by the array. According to Pure Storage hardware documentation, the mandatory COM port settings are:
* Baud Rate (Speed): 115,200
* Data Bits: 8
* Parity: None (N)
* Stop Bits: 1
* Flow Control: None
This configuration is universally abbreviated as 115200 8-N-1 . If an engineer attempts to use older standard speeds (like 9600 or 38400 baud) or leaves flow control (like Xon/Xoff or RTS/CTS) enabled, the terminal window will display unreadable, garbled characters (often referred to as "wingdings"), or the keyboard inputs will fail to register entirely, preventing the initialization of the array.
NEW QUESTION # 120
An Implementation Engineer is deploying a FlashArray//XLR5 with two DirectFlash Shelves. The engineer wants to ensure the shelves are installed in the preferred PCIe slots to achieve optimal performance and support. Which PCIe slots should the Implementation Engineer use for connecting the DFS shelves?
Answer: B
Explanation:
The FlashArray//XL platform features a split-chassis design with a unique PCIe bus layout compared to the standard //X series. To maintain optimal performance and redundancy, the backend connectivity for DirectFlash Shelves (DFS) must be balanced across the specific PCIe root complexes managed by the dual CPUs.
For a configuration involving multiple shelves (specifically targeting the logical shelf identifiers SH8 and SH9, which often correspond to the first pair of backend loops in an //XL deployment), the validated configuration is to use PCIe Slot 0 and PCIe Slot 6. These slots are architecturally designated for the backend NVMe-oF (RoCE) fabric cards.
Using Slot 0 (typically located on the far left) and Slot 6 (located on the right side of the chassis) ensures that the I/O load is distributed across the internal midplane and CPUs correctly. Placing cards in incorrect slots (like Slot 1 or 7, which might be reserved for host I/O or inter-controller links) can result in shelf detection failures or performance bottlenecks where one CPU is overloaded with backend traffic while the other is idle.
=========
NEW QUESTION # 121
At the completion of an upgrade, which command is used to send phonehome logs?
Answer: B
Explanation:
At the completion of an upgrade, the correct command to manually trigger the upload of the relevant logs is purearray phonehome --send-today.
Purpose: This specific argument (--send-today) instructs the array to bundle and upload all log files generated within the current 24-hour window. This is the standard procedure post-upgrade because it ensures that all logs capturing the pre-upgrade state, the upgrade process itself, and the immediate post-upgrade health checks are transmitted to Pure Support.
Verification: This allows the Support team to validate that the upgrade completed successfully and that no dormant issues were triggered during the controller failovers.
Syntax: Option A (purelogs) is not a valid command. Option B (--send-logs) is a generic approximation, but the specific "today" flag is the best practice command cited in upgrade checklists to avoid uploading gigabytes of historical data irrelevant to the immediate event.
NEW QUESTION # 122
An Implementation Engineer has completed a hardware NDU, but after the upgrade, Purity reports a "health not responding" status when running status. Before contacting support, which command should the Implementation Engineer run to review a list of possible logged issues?
Answer: A
Explanation:
After a complex operation like a Hardware Non-Disruptive Upgrade (HWNDU), the Purity health services may occasionally stall or report generic errors like "health not responding." Standard alert commands (purealert list) might be empty or show generic "service unavailable" messages because the alerting service itself depends on the health system.
To troubleshoot this, the Implementation Engineer should dig deeper into the system's internal message log using puremessage list --open --hidden.
puremessage accesses the raw message bus of the array, which captures lower-level events than standard alerts.
--hidden is the critical flag here; it reveals internal system messages that are typically suppressed from the standard user view to avoid noise.
These hidden messages often contain the specific error codes or service failure reasons (e.g., "timeout waiting for daemon X") that explain why the health status is hanging. Providing this output to Pure Support significantly accelerates the root cause analysis. purearray diagnose is not a standard command for this purpose, and purealert watcher is for configuring notification recipients, not viewing log contents.
NEW QUESTION # 123
......
Latest FlashArray-Implementation-Specialist Test Online: https://www.dumpsreview.com/FlashArray-Implementation-Specialist-exam-dumps-review.html
What's more, part of that DumpsReview FlashArray-Implementation-Specialist dumps now are free: https://drive.google.com/open?id=1flVSvoTYl9EaNp2JXn-NyeYE9uLiHBv4