Fast2test為你提供了一個明確而優秀的選擇,為你減少煩惱。想早點成功嗎?早點拿到Pure Storage FlashArray-Storage-Professional認證考試的證書嗎?快點將Fast2test加入購物車吧。Fast2test會給你很好的指導,能確保你通過考試。使用Fast2test你可以很快獲得你想要的證書。
| 主題 | 簡介 |
|---|---|
| 主題 1 |
|
| 主題 2 |
|
| 主題 3 |
|
| 主題 4 |
|
| 主題 5 |
|
>> FlashArray-Storage-Professional權威認證 <<
您應該尋找那些真實可信的題庫商提供的FlashArray-Storage-Professional題庫資料,這樣對您通過考試是更有利,可信度高的Pure Storage FlashArray-Storage-Professional題庫可幫助您快速通過認證考試,而Fast2test公司就是這樣值得您信賴的選擇。FlashArray-Storage-Professional題庫資料中的每個問題都由我們專業人員檢查審核,為考生提供最高品質的考古題。如果您希望在短時間內獲得Pure Storage FlashArray-Storage-Professional認證,您將永遠找不到比Fast2test更好的產品了。
問題 #24
A network admin is trying to setup Pure1 access and phone home logging on the array.
What port should the admin ensure is opened for the array?
答案:C
解題說明:
Pure1 and Phone Home: Pure1 is a cloud-based management and monitoring platform. For the FlashArray to communicate its health data, performance metrics, and alerts to Pure Storage, it must be able to "Phone Home." The Power of HTTPS: This communication is encrypted and sent via the HTTPS protocol. Consequently, the standard port for HTTPS, TCP 443, must be opened for outbound traffic on the management network.
Firewall Configuration: The array controllers initiate an outbound connection to the Pure Storage cloud (specifically to destinations like cloud-connect.purestorage.com). Because it is an outbound-initiated connection, most stateful firewalls will allow the return traffic automatically once port 443 is permitted.
Why Option A is incorrect: Port 22 (SSH) is used for secure shell access to the array's CLI. While essential for local administration, it is not used for the automated Phone Home or Pure1 telemetry data stream.
Why Option B is incorrect: Port 8117 was historically used for the "Remote Assist" tunnel in older Purity versions. However, even for Remote Assist, modern Purity versions have transitioned to using port 443 to simplify firewall rules for customers. It is not the standard port for the general Phone Home/Pure1 logging service.
Verification: An administrator can verify connectivity by running the purearray test phonehome command in the CLI. If port 443 is blocked, the test will fail with a connection timeout.
問題 #25
An administrator is attempting to add a volume to a volume group but it does not show up in the list of volumes available to move in, even though it does show up in the volumes pane.
Why is the volume missing?
答案:C
解題說明:
In the Pure Storage Purity operating environment, a volume can only be a member of one Volume Group at a time.
When an administrator navigates to a Volume Group in the GUI and clicks to add members, the system filters the inventory and only displays volumes that are currently "unassigned" (not belonging to any Volume Group). If a volume is already residing inside another Volume Group, Purity intentionally hides it from this available list to prevent conflicting overlapping memberships. To resolve this, the administrator must first navigate to the volume's current Volume Group, remove the volume from that group, and then it will become available to add to the new one.
Here is why the other options are incorrect:
It is already part of a Protection Group (B): Protection Groups (pgroups) manage snapshot and replication schedules. A volume can absolutely be a standalone member of a Protection Group while simultaneously being added to a Volume Group. Being in a pgroup does not hide it from the vgroup selection list.
It is protected by SafeMode (C): SafeMode is a ransomware protection feature that prevents the manual eradication of destroyed volumes and snapshots before their retention timer expires. It does not dictate or restrict logical organizational containers like Volume Groups.
問題 #26
How are in-progress asynchronous snapshot transfers monitored from the UI?
答案:B
解題說明:
According to official Pure Storage documentation regarding Asynchronous Replication management, while replication throughput (bandwidth) can be viewed globally on the Analysis tab, the actual replication status for in-progress snapshot transfers is tracked and monitored on the replication target.
To monitor an in-progress asynchronous transfer from the GUI, a storage administrator must log into the target FlashArray, navigate to Storage -> Protection Groups, and look at the Transfers section within the Protection Group Snapshots panel. This view explicitly details the time the replicated snapshot was created on the source, the time the transfer started, and the current progress of the snapshot being received. If a transfer is currently in-progress, the "Completed" column will remain blank until the snapshot is fully safely written to the target array.
Here is why the other options are incorrect:
From the replication source (C): While the source orchestrates the creation of the snapshot and initiates the data push, the granular transfer completion status and historical transfer logs of the incoming snapshots are tracked on the target's Protection Group interface.
From the either the replication source or target (B): Because the specific "Transfers" tracking panel for asynchronous protection group snapshots is located on the receiving end (target), monitoring the granular completion status cannot be done symmetrically from either side in the UI.
問題 #27
An administrator is setting up FA File using the FlashArray GUI. The company is an NFS only shop and needs to configure their remote user authentication.
Which of the following GUI locations should the administrator use to configure access?
答案:B
解題說明:
For FlashArray File Services (FA File), user authentication and mapping depend on the storage protocol being used. In an NFS-only environment, remote user authentication (resolving UNIX UIDs and GIDs to actual usernames and managing access) is typically handled via LDAP or NIS.
To configure this integration in the Purity GUI, the storage administrator must navigate to Settings > Access > Directory Services. This specific section allows the FlashArray to connect to a centralized directory server (such as OpenLDAP or even Active Directory providing LDAP services) to pull the necessary UNIX user and group attributes required for NFS file permissions to function properly.
Here is why the other options are incorrect:
Settings > Access > Create Active Directory Account (A): This specific menu path is used strictly for configuring native Active Directory (AD) computer accounts and joining the domain to support the SMB (Server Message Block) protocol. Since the scenario explicitly states the company is an "NFS only shop," configuring an SMB AD account is not the correct step.
Settings > Access > File System (C): While you manage file-level exports and policies within the Purity file interface, the global configuration for remote user authentication and directory server integration lives under the dedicated Directory Services pane.
問題 #28
A customer with an X50R2 array connected to 110V power is due for an upgrade to the latest controller generation.
What is required to allow this upgrade to proceed?
答案:A
解題說明:
As Pure Storage has iterated through FlashArray generations (moving from //X R2 to R3, R4, and beyond), the power density and performance capabilities of the controllers have increased significantly. Modern high-performance controllers, such as those found in the //X R4 or //XL series, have strict power requirements that often exceed what a standard 110V/120V (Low-Line) circuit can provide.
To support the higher wattage and current draw of modern CPUs and NVRAM modules, Pure Storage requires 200-240V (High-Line) power for its latest generation controllers. If an existing array is currently running on 110V power, it must be migrated to 220V power outlets before the upgrade can proceed. Attempting to run newer, high-spec controllers on 110V power could lead to power supply instability, insufficient cooling performance, or the controllers failing to boot entirely.
Here is why the other options are incorrect:
Call support to schedule a power supply replacement (A): The issue is not a faulty power supply; it is the external electrical infrastructure's inability to provide the necessary voltage/wattage for the new hardware. Replacing the power supply with the same model would not solve the voltage limitation.
Transition the array to DC power (B): While Pure Storage does offer DC power options for specific telco environments, this is not a standard requirement for a typical controller upgrade. Moving to standard high-line AC power (220V) is the standard prerequisite for data center environments.
問題 #29
......
如果你要參加Pure Storage的FlashArray-Storage-Professional認定考試,Fast2test的FlashArray-Storage-Professional考古題是你最好的準備工具。這個資料可以幫助你輕鬆地通過考試。這是一個評價很高的資料,有了它,你就不用再擔心你的考試了。因為這個考古題可以解決你在準備考試時遇到的一切難題。在購買Fast2test的FlashArray-Storage-Professional考古題之前,你還可以下載免費的考古題樣本作為試用。這樣你就可以自己判斷這個資料是不是適合自己。
FlashArray-Storage-Professional學習資料: https://tw.fast2test.com/FlashArray-Storage-Professional-premium-file.html