What's more, part of that PassReview FlashArray-Storage-Professional dumps now are free: https://drive.google.com/open?id=1zjvHqaqeQc9NU2HDdgRDaf49eSPB52si
Before making a final purchase, PassReview customers can try the features of the FlashArray-Storage-Professional practice material with a free demo. If a customer purchases our FlashArray-Storage-Professional exam preparation material, we will provide them with Free FlashArray-Storage-Professional Exam Questions updates for up to 1 year. If the FlashArray-Storage-Professional certification test content changes after your purchase within 1 year, you will instantly get free real questions updates.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
>> FlashArray-Storage-Professional Reliable Exam Papers <<
You can learn from your Pure Certified FlashArray Storage Professional (FlashArray-Storage-Professional) practice test mistakes and overcome them before the actual Pure Certified FlashArray Storage Professional (FlashArray-Storage-Professional) exam. The software keeps track of the previous Pure Certified FlashArray Storage Professional (FlashArray-Storage-Professional) practice exam attempts and shows the changes of each attempt. You don't need to wait days or weeks to get your performance report. The software displays the result of the Pure Storage FlashArray-Storage-Professional Practice Test immediately, which is an excellent way to understand which area needs more attention.
NEW QUESTION # 23
An administrator is running commands to verify NVME/TCP connectivity from the hosts to the FlashArray. They use the command ping -M do -s 8972 <ip_addr> from the initiator and it fails.
What should the administrator do to resolve the issue?
Answer: A
Explanation:
When configuring NVMe/TCP (or iSCSI) for optimal performance on a Pure Storage FlashArray, configuring Jumbo Frames (an MTU of 9000) end-to-end is a standard best practice.
The command ping -M do -s 8972 <ip_addr> is specifically used to verify Jumbo Frame configuration across the network.
The -M do flag sets the "Do Not Fragment" (DF) bit, meaning the network is not allowed to break the packet into smaller pieces.
The -s 8972 flag sets the ICMP data payload to 8972 bytes. When you add the standard 8-byte ICMP header and the 20-byte IP header, the total packet size equals exactly 9000 bytes.
If this ping command fails, it indicates that somewhere along the network path between the host (initiator) and the FlashArray (target), a switch port, router, or network interface is not configured to support an MTU of 9000. The packet is being dropped because it is too large and cannot be fragmented. The administrator must verify the MTU settings on every network hop (switches, routers, and host NICs) to resolve the issue.
Here is why the other options are incorrect:
Engage support to enable NVME/ TCP services (A): The failure of a Jumbo Frame ping test is a Layer 2/Layer 3 network configuration issue, not an indicator that the NVMe/TCP storage protocol service is disabled on the array.
Run the command from the target (C): While pinging from the FlashArray back to the host is a valid secondary troubleshooting step, it will likely also fail if the network path doesn't support Jumbo Frames. The actual resolution is to fix the MTU on the network hops.
NEW QUESTION # 24
During a test failover using ActiveDR, what content will be presented to the target pod?
Answer: C
Explanation:
ActiveDR is Pure Storage's continuous, near-sync replication solution. It differs fundamentally from standard asynchronous replication because it uses a continuous stream of data rather than snapshot-based "periodic refreshes" (which eliminates Option A).
When you perform a test failover in ActiveDR, you do so by promoting the target pod. The target pod becomes writable, allowing your hosts and applications to run against the replicated data without disrupting the ongoing continuous replication from the source array in the background.
When the test is completed, you demote the target pod. To ensure that the data generated during your test failover isn't accidentally lost forever, ActiveDR automatically creates an undo pod at the exact moment of demotion.
If you need to resume that exact test failover scenario or recover the test data, you can re-promote the target pod and instruct ActiveDR to present the content from the undo pod. This unique mechanism allows storage administrators to seamlessly non-disruptively test, pause, and resume DR environments without affecting production protection.
NEW QUESTION # 25
If an NFS client can mount the FA File export shares with the IP address, but not the fully qualified domain name, what is most likely causing the issue?
Answer: A
Explanation:
When an NFS client successfully mounts an export using the target's IP address, it proves that the fundamental network connectivity (routing, firewalls) and the storage protocol layer (NFS export policies, host access permissions) are functioning correctly.
However, if the exact same mount attempt fails when using the Fully Qualified Domain Name (FQDN) of the FlashArray file service, the issue lies entirely with name resolution. The Domain Name System (DNS) is responsible for translating human-readable FQDNs into the IP addresses required for network communication. If the client cannot reach the DNS server, or if the DNS server lacks the correct A or AAAA records for the FlashArray's file Virtual IP (VIP) addresses, the client won't be able to resolve the name to the IP, causing the mount command to fail.
Here is why the other options are incorrect:
Issue with the Active Directory (AD) controller (A): Active Directory is primarily used for directory services, user authentication, and authorization (such as mapping permissions for SMB or NFSv4). While AD environments usually include DNS, an "AD controller issue" in the context of storage protocols usually points to permission denials, not host name resolution failures. Furthermore, since the mount works via IP, basic access is already validated.
Issue with the OpenLDAP (C): Similar to AD, OpenLDAP provides directory services for user mappings (UID/GID) and authentication. It does not perform FQDN-to-IP resolution.
NEW QUESTION # 26
What should an administrator configure when setting up device-level access control in an NVMe/TCP network?
Answer: B
Explanation:
In any NVMe-based storage fabric (including NVMe/TCP, NVMe/FC, and NVMe/RoCE), the standard method for identifying endpoints and enforcing device-level access control is the NQN (NVMe Qualified Name).
The NQN serves the exact same purpose in the NVMe protocol as an IQN (iSCSI Qualified Name) does in an iSCSI environment, or a WWPN (World Wide Port Name) does in a Fibre Channel environment. It is a unique identifier assigned to both the host (initiator) and the storage array (target subsystem). When setting up access control on a Pure Storage FlashArray, the storage administrator must capture the Host NQN from the operating system and configure a Host object on the array with that specific NQN. This ensures that only the authorized host can discover, connect to, and access its provisioned NVMe namespaces (volumes).
Here is why the other options are incorrect:
VLANs (A): Virtual LANs are used for network-level isolation and segmentation at Layer 2 of the OSI model. While you might use a VLAN to separate your storage traffic from your management traffic, it is a network security measure, not a device-level access control mechanism for the storage protocol itself.
LACP (C): Link Aggregation Control Protocol (LACP) is a network protocol used to bundle multiple physical network links into a single logical link for redundancy and increased bandwidth. It has nothing to do with storage access control or mapping volumes to hosts.
NEW QUESTION # 27
What is a potential indicator of incorrect configuration on a Pure Storage FlashArray?
Answer: C
Explanation:
Understanding CRC Errors: CRC (Cyclic Redundancy Check) errors occur when the data received at a port does not match the checksum sent by the initiator or switch. In a Pure Storage environment, these are tracked per port and can be viewed via the CLI (purehw list) or the GUI.
Configuration vs. Hardware: While a failing SFP or a damaged fiber cable can cause CRC errors, they are a primary indicator of configuration mismatches in the SAN fabric. Common culprits include:
Port Speed Mismatches: Manually setting a port to 16Gbps when the switch is set to "Auto" or 8Gbps.
Duplex Mismatches: Though rare in modern Fibre Channel, it is a classic Ethernet/iSCSI configuration error.
MTU Mismatches: In iSCSI or NVMe-oF environments, if the FlashArray is configured for Jumbo Frames (MTU 9000) but the switch or host is at MTU 1500, packet fragmentation or CRC-like errors/drops will occur.
Why Option A is incorrect: A blinking status LED on a controller is often part of normal operation (indicating heartbeat or activity). A solid amber LED would be an indicator of a hardware failure, not necessarily a misconfiguration.
Why Option C is incorrect: While latency spikes can be caused by misconfiguration (like incorrect MPIO settings), they are more commonly symptoms of workload changes, "noisy neighbors," or reaching the physical performance limits of the array. CRC errors are a much more specific diagnostic "smoking gun" for port and fabric configuration issues.
Best Practice: When CRC errors are detected, Pure Storage recommends first checking the physical layer (reseating SFPs/cables) and then verifying that the port speed and protocol settings on the FlashArray match the upstream switch configuration exactly.
NEW QUESTION # 28
......
Desktop Pure Storage FlashArray-Storage-Professional Practice Exam Software is a one-of-a-kind and very effective software developed to assist applicants in preparing for the Pure Storage FlashArray-Storage-Professional certification test. The Desktop Pure Storage FlashArray-Storage-Professional Practice Exam Software that we provide includes a self-assessment feature that enables you to test your knowledge by taking simulated tests and evaluating the results.
FlashArray-Storage-Professional Accurate Answers: https://www.passreview.com/FlashArray-Storage-Professional_exam-braindumps.html
2026 Latest PassReview FlashArray-Storage-Professional PDF Dumps and FlashArray-Storage-Professional Exam Engine Free Share: https://drive.google.com/open?id=1zjvHqaqeQc9NU2HDdgRDaf49eSPB52si