질문 # 16
resume is enabled and a health check first fails and then passes?
정답:B
설명:
Comprehensive and Detailed Explanation From BIG-IP Administration Support and Troubleshooting documents: The "Manual Resume" feature is a safety mechanism used when a pool is not working as expected due to flapping services or unstable backend applications. Normally, when a health monitor fails, the pool member is marked "Offline" (Red), and when the monitor passes, it automatically returns to "Available" (Green)47. However, if "Manual Resume" is enabled, the BIG-IP will not automatically put the member back into rotation after a failure48. Even if the health check begins to pass again, the member remains in an "Offline (Disabled)" state49. This requires an administrator to manually intervene and re-enable the member. This is a common point of confusion when troubleshooting; a member may show passing health checks but still not receive traffic because it is waiting for a manual administrative "resume" command. This feature is intended to prevent "unhealthy" servers from receiving traffic until an engineer has confirmed the root cause of the initial failure was resolved.
질문 # 17
A BIG-IP Administrator creates a new Virtual Server. The end user is unable to access the page.
During troubleshooting, the administrator learns that the connection between the BIG-IP system and server is NOT set up correctly. What should the administrator do to solve this issue?
정답:D
설명:
When a virtual server is not working as expected despite the pool members being marked "UP" (Green), the issue is frequently a return-path routing failure. If the BIG-IP forwards a request with the original client's source IP address, the backend server will try to respond directly to that client.
If the server does not have its default gateway pointed back to the BIG-IP, the response packet will be routed elsewhere (or dropped), resulting in a connection timeout for the user. To resolve this, the administrator must configure "Source Address Translation" (SNAT). By setting SNAT to
"Automap" or a specific SNAT address, the BIG-IP replaces the client's IP with its own internal self-IP. The backend server then sees the BIG-IP as the source and sends the response back to it locally. This troubleshooting step ensures a functional, symmetric traffic flow. Identifying the need for SNAT is one of the most common troubleshooting tasks for new virtual server deployments where the BIG-IP is not the default gateway for the backend servers.
질문 # 18
A BIG-IP Administrator suspects that one of the BIG-IP device power supplies is experiencing power outages. Which log file should the BIG-IP Administrator check to verify the suspicion?
(Choose one answer)
정답:A
설명:
According toofficial F5 documentation (K52015891 ?Troubleshooting BIG-IP power supply issues),hardware-related alerts for power supplies, fans, and chassis components are logged in
/var/log/ltm.
When a BIG-IP device experiences a power supply issue--such as failure, intermittent outages, or fan-related faults--the system generates alerts through internal platform monitoring services.
These alerts are written to the/var/log/ltmfile and often appear with messages similar to:
Chassis power supply 2 has experienced an issue. Status is as follows: FAN=bad; STATUS=bad.
This makes /var/log/ltm theauthoritative log filefor identifying and verifying power supply and chassis-related problems on BIG-IP systems.
질문 # 19
A BIG-IP Administrator suspects that one of the BIG-IP device power supplies is experiencing power outages. Which log file should the BIG-IP Administrator check to verify the suspicion?
정답:A
설명:
On a BIG-IP system, hardware-related alerts, including those for power supply units (PSUs), fans, and chassis components, are primarily logged in the Local Traffic Manager (LTM) log file.
Log Location: The file path is /var/log/ltm.
PSU Alert Messages: When a power supply fails, experiences an outage, or is unplugged, the chmand (Chassis Manager) or system_check processes log specific error codes to this file. For example, you may see messages like 010d0006:0: Chassis power supply <X> has experienced an issue or VINPUT=bad.
Troubleshooting: Administrators can use the command grep -i "power supply" /var/log/ltm to quickly filter for PSU-related events.
질문 # 20
A BIG-IP Administrator configured the following virtual server to pass traffic on all addresses and ports. After configuration is completed, the BIG-IP Administrator notices that the virtual server is unable to pass traffic.
ltm virtual forwarding_any_vs {
destination 0.0.0.0:any
ip-forward
mask 255.255.255.255
profiles {
fastL4 { }
}
serverssl-use-sni disabled
source 0.0.0.0/0
translate-address disabled
translate-port disabled
}
Which part of the configuration is the cause of the issue? (Choose one answer)
정답:B
설명:
This virtual server is intended to function as a forwarding (IP-forwarding) virtual server, which is commonly used for routing or firewall-style deployments where BIG-IP forwards traffic transparently without load balancing or address translation. For a forwarding virtual server to match and pass all traffic, the destination must be configured as 0.0.0.0:any with a mask of 0.0.0.0, not 255.255.255.255.
The configured mask 255.255.255.255 represents a /32 host mask, which restricts the virtual server to matching traffic destined only for the exact IP address 0.0.0.0. Since 0.0.0.0 is not a valid routable destination for normal traffic, no packets will ever match the virtual server, causing it to pass no traffic at all.
This is a well-documented BIG-IP behavior:
destination 0.0.0.0:any
mask 0.0.0.0
together define a catch-all forwarding virtual server.
The destination itself (Option A) is correct for a forwarding VS, and disabling address translation (Option C) is expected and required for IP-forwarding mode. Therefore, the incorrect subnet mask is the sole reason the virtual server is not functioning as expected.