With the excellent NSEI_OTS_AR-7.6 exam braindumps, our company provides you the opportunity to materialize your ambitions with the excellent results. Using our NSEI_OTS_AR-7.6 praparation questions will enable you to cover up the entire syllabus within as minimum as 20 to 30 hours only. And we can clam that, as long as you focus on the NSEI_OTS_AR-7.6 training engine, you will pass for sure. And the benefit from our NSEI_OTS_AR-7.6 learning guide is enormous for your career enhancement.
| Section | Objectives |
|---|---|
| Asset management | - Implement device detection on FortiGate and FortiNAC - Explain OT standard and Fortinet compliance - Fortinet Security Fabric for an OT network |
| Network security | - Configure virtual patching - Configure security inspections for industrial protocols - Configure automation |
| Network access control | - Configure network access authentication - Configure network segmentation schemas - Explain OT Ethernet concepts |
| Monitoring and risk assessment | - Create FortiAnalyzer event handlers - Perform risk assessment and management - Analyze security reports from FortiAnalyzer |
>> Reliable NSEI_OTS_AR-7.6 Exam Dumps <<
Test engine version is a simulation of real test; you can feel the atmosphere of formal test. You can well know your shortcoming and strength in the course of practicing Fortinet exam dumps. It adjusts you to do the NSEI_OTS_AR-7.6 Certification Dumps according to the time of formal test. Most IT workers like using it to test NSEI_OTS_AR-7.6 practice questions and their ability.
NEW QUESTION # 43
What is the main OT component for monitoring and controlling industrial processes? (Choose one answer)
Answer: C
Explanation:
The correct answer is C. Industrial Control System (ICS) . The study guide states that "ICS is a main component of OT" and "consists of systems used for monitoring and controlling industrial processes." It also explains that ICS includes various devices, systems, controls, and networks that manage industrial processes, and that the most common types are SCADA and distributed control systems (DCS) . This makes ICS the primary OT component for monitoring and controlling industrial processes.
The other options are related OT components, but they are not the best answer to this wording. SCADA collects real-time data and helps visualize and control the OT environment, but it is described as a system within the broader ICS structure. PLC devices collect and transmit real-time data and connect sensors and RTUs to SCADA, while IIoT refers to sensors, actuators, and other connected field devices. Therefore, the overarching main OT component for monitoring and controlling industrial processes is ICS .
NEW QUESTION # 44
As the first step in your OT network protection plan, you must identify the OT protocols that the FortiGate device supports. Which two configurations must you implement on this FortiGate device? (Choose two answers)
Answer: A,C
Explanation:
The correct answers are B and C . The study guide states that "You can use application control signatures to detect OT protocols" and that "Application control detects the protocols used in applications like Modbus, IEC 104, and the contents of the telecontrol messages" . It also shows that a Modbus application control profile can be enabled on a firewall policy "for OT protocol visibility in the monitor status." This directly supports B , because application control is the feature used to identify and monitor OT protocols on FortiGate.
The guide also explains under IPS that "By default, OT signatures are excluded from the signatures lists on the GUI until you enable them on the CLI" using config ips global and set exclude-signatures none .
Once enabled, FortiGate can use those OT signatures for OT-aware inspection and protection. That supports C as the second required configuration. A is related to device discovery, not protocol identification, and D is focused on exploit and vulnerability detection rather than the first-step goal of identifying OT protocols.
NEW QUESTION # 45
Refer to the exhibit.
A partial OT network is shown. You want to configure an automated alert sent by FortiAnalyzer when an attack occurs on a FortiGate device. Which two configurations must you implement? (Choose two answers)
Answer: B,C
Explanation:
The correct answers are A and D . The study guide provides a direct use case called Attack Detection and Automated Alert . It states: "A downstream FortiGate detects an attack and sends logs to FortiAnalyzer. FortiAnalyzer parses the logs and notifies the root FortiGate. The root FortiGate triggers the action, which in this case, is a notification to the administrator." The same slide also explicitly shows "Stitches configured on root FortiGate." This confirms that to send the automated alert, you must configure the automation stitch on the root FortiGate .
The second required configuration is an event handler on FortiAnalyzer . The guide explains that "Event handlers generate events" and that "FortiAnalyzer uses event handlers to filter all incoming logs. If logs match the conditions configured in an event handler, FortiAnalyzer generates an event." Since FortiAnalyzer must detect the attack from the received logs before notifying the root FortiGate, an event handler is required on FortiAnalyzer.
Option B is incorrect because the study guide does not identify a LOCALHOST task as the required configuration for this attack-alert flow. Option C is also incorrect because the question asks what must be configured to enable the automated alert workflow . An IPS profile may detect some attacks, but the required automation path in the study guide is specifically event handler on FortiAnalyzer + stitch on the root FortiGate .
NEW QUESTION # 46
During layer 2 polling , which two pieces of information are gathered by FortiNAC to identify a device?
(Choose two answers)
Answer: A,C
NEW QUESTION # 47
Refer to the exhibit.
Which statement about this partial Asset Identity List page is correct? (Choose one answer)
Answer: D
Explanation:
Based on the OT Security 7.6 Architect study guide regarding the Asset Identity Center and Asset Management :
* Vulnerability Visibility : The Asset Identity List tab displays key metadata for IT and OT devices, including detected addresses, users, and a specific column for Vulnerabilities .
* Virtual Patching Feature : In the OT Security 7.6 architecture, the " Vulnerabilities " column is populated through the OT Security Service license, which includes " OT vulnerability correlation definitions & virtual patching signatures " .
* Correlation Mechanism : FortiGate extracts metadata from OT traffic and uses these signatures to identify known vulnerabilities on the assets. For these vulnerabilities to be identified and correlated in the Asset Identity Center as shown in the exhibit (displaying a count of 8 vulnerabilities), the Virtual Patching feature must be active.
* Architectural Implementation : Virtual patching is a critical component of the " Protection " layer in OT networks, allowing administrators to secure legacy or unpatchable PLCs and RTUs by blocking exploit attempts at the network level using IPS-based virtual patching signatures.
* Exhibit Analysis : The presence of identified vulnerabilities (the number " 8 " in the red shield) in the Asset Identity List confirms that the FortiGate is actively performing vulnerability correlation, which is the operational result of having a Virtual Patching security profile applied to the relevant firewall policy.
NEW QUESTION # 48
......
If you find you are extra taxed please tell us in time before purchasing our NSEI_OTS_AR-7.6 reliable Study Guide materials. Sometimes the key point is the information tax. Some countries may require buyers to pay extra information tax. How to avoid this tax while purchasing Fortinet NSEI_OTS_AR-7.6 Reliable Study Guide materials? You can choose to pay by PayPal with credit card. PayPal doesn't have extra costs. Here you don't need have a PayPal account; a credit card is the necessity for buying NSEI_OTS_AR-7.6 reliable Study Guide.
NSEI_OTS_AR-7.6 Valid Test Tips: https://www.exam-killer.com/NSEI_OTS_AR-7.6-valid-questions.html