NETA NETA_2 Exam Syllabus Topics:

SectionWeightObjectives
Component Testing20-25%- Transformers Testing
  • 1. Turns Ratio Tests
  • 2. Winding Resistance Tests
  • 3. Excitation Current Tests
- Switchgear Testing
  • 1. Dielectric Withstand Tests
  • 2. Circuit Breaker Timing Tests
  • 3. Contact Resistance Tests
- Protective Devices Testing
  • 1. Coordination Studies
  • 2. Overcurrent Relay Tests
- Conductors and Cables Testing
  • 1. Continuity Tests
  • 2. Insulation Resistance Tests
  • 3. Hi-Pot Tests
Testing Equipment and Instrumentation20-25%- Voltmeters and Ammeters
  • 1. Clamp Meters
  • 2. Digital Multimeters
- Relay Testing Equipment
  • 1. Protective Relay Testers
- Insulation Testing Equipment
  • 1. Hipot Testers
  • 2. Megohmmeters
  • 3. Insulation Resistance Analyzers
- Grounding and Bonding Testers
  • 1. Ground Bond Testers
  • 2. Earth Resistance Testers
- Circuit Breaker Testers
  • 1. Primary Injection Test Sets
  • 2. Secondary Injection Test Sets
Electrical Theory and Fundamentals15-20%- Electrical Safety Principles
  • 1. Personal Protective Equipment
  • 2. Arc Flash Safety
  • 3. Lockout/Tagout Procedures
- AC/DC Circuit Analysis
  • 1. Kirchhoff's Laws
  • 2. Series and Parallel Circuits
  • 3. Ohm's Law and Power Calculations
  • 4. Three-Phase Systems
Documentation and Reporting10-15%- Test Documentation
  • 1. Test Results Interpretation
  • 2. Data Recording Procedures
- Reports and Certification
  • 1. Test Report Writing
  • 2. NRTL Certification Requirements
Testing Procedures and Standards25-30%- NFPA 70E Electrical Safety
  • 1. Arc Flash Hazard Analysis
  • 2. energized Work Permits
- IEEE Testing Standards
  • 1. IEEE 62.45 Low-Voltage Testing
  • 2. IEEE 4 High-Voltage Testing
- NETA Maintenance Testing Specifications
  • 1. Acceptance Testing Standards
  • 2. Electrical Testing Procedures
  • 3. Visual Inspection Procedures

>> NETA_2関連日本語内容 <<

NETA NETA_2模擬問題集 & NETA_2一発合格

NETA_2トレーニング資料のPDFバージョンは読みやすく、覚えやすく、印刷リクエストをサポートしているため、紙で印刷して練習することができます。練習資料のソフトウェアバージョンは、シミュレーションテストシステムをサポートし、セットアップの時間を与えることには制限がありません。

NETA Level 2 Certified Assistant Electrical Testing Specialist 認定 NETA_2 試験問題 (Q17-Q22):

質問 # 17
Sample valves should be flushed with at least how much waste liquid before collecting a transformer oil sample?

正解:B

解説:
NETA-recommended oil sampling practices require flushing the sampling valve withat least one quartof waste liquid. This removes stagnant oil, debris, and contaminants that could skew test results.
Accurate oil analysis depends heavily on proper sampling technique. NETA Level 2 technicians must follow flushing and cleanliness requirements to ensure valid dielectric and moisture analysis.


質問 # 18
When personnel are working in apermitted confined space, how many attendants must remain outside the space and for how long?

正解:B

解説:
Confined space safety requirements mandate thatat least one trained attendantremain outside the spacefor the entire duration of the entry operation. The attendant monitors conditions, maintains communication, and initiates rescue procedures if needed. NETA Level 2 technicians must comply with confined space protocols when testing transformers, vaults, or enclosed switchgear compartments.


質問 # 19
Transformer oil samples drawn when the oil temperature isbelow 32°F (0°C)may:

正解:B

解説:
At low temperatures, free water can solidify and remain suspended, preventing accurate detection. NETA Level 2 technicians must consider temperature effects when interpreting oil analysis results.


質問 # 20
To reverse the direction of rotation of a three-phase induction motor, which action is required?

正解:C

解説:
The direction of rotation of a three-phase motor is determined by thephase sequenceof the supply voltage.
Reversingany two phase conductorschanges the phase sequence, which reverses the rotating magnetic field in the stator and therefore reverses motor rotation.
NETA Level 2 technicians frequently verify motor rotation during commissioning and after maintenance.
Understanding phase rotation is essential when performing bump tests, troubleshooting incorrect rotation, or verifying wiring after motor replacement. Reversing all three phases would preserve the original phase sequence and would not change rotation.


質問 # 21
What is the recommendedminimum insulation resistance valuefor motor windings manufactured before
1970?

正解:B

解説:
For older motor windings, NETA guidance recognizes that insulation systems were often less robust than modern designs. The recommended minimum insulation resistance is100 megohms per kV of rated voltage plus 1 megohm.
This formula provides a baseline for evaluating insulation condition during acceptance or maintenance testing.
NETA Level 2 technicians must not only perform insulation resistance tests correctly, but also interpret results in the context of equipment age, voltage rating, and service conditions. Results below recommended minimums indicate potential moisture, contamination, or insulation degradation requiring corrective action.


質問 # 22
......

NETA_2「NETA Level 2 Certified Assistant Electrical Testing Specialist」試験は簡単ではありません。専門的な知識が必要で、もしあなたはまだこの方面の知識を欠かれば、JPNTestは君に向ける知識を提供いたします。JPNTestの専門家チームは彼らの知識や経験を利用してあなたの知識を広めることを助けています。そしてあなたにNETA_2試験に関するテスト問題と解答が分析して差し上げるうちにあなたのIT専門知識を固めています。

NETA_2模擬問題集: https://www.jpntest.com/shiken/NETA_2-mondaishu

無料でクラウドストレージから最新のJPNTest NETA_2 PDFダンプをダウンロードする:https://drive.google.com/open?id=18OznR1TOJCVX9zAjnQWAby90vlFZVs-S