BONUS!!! Download part of Dumpleader NCM-MCI-6.10 dumps for free: https://drive.google.com/open?id=1N90Ig6NdnJrKu5O3kF3bYnTVjyOEvDwm
We all have the right to pursue happiness. Also, we have the chance to generate a golden bowl for ourselves. Now, our NCM-MCI-6.10 practice materials can help you achieve your goals. As we all know, the pace of life is quickly in the modern society. So we must squeeze time to learn and become better. With the NCM-MCI-6.10 Certification, your life will be changed thoroughly for you may find better jobs and gain higher incomes to lead a better life style. And our NCM-MCI-6.10 exam questions will be your best assistant.
| Section | Weight | Objectives |
|---|---|---|
| Virtualization and VM Performance Optimization | 15% | - Performance metrics analysis and tuning - VM resource adjustment and optimization - AHV administration and workload management - High availability and migration management |
| Analyze and Optimize Storage Performance | 20% | - Troubleshoot storage performance bottlenecks - Understand storage internals and I/O patterns - Evaluate and resolve competing workload requirements - Optimize storage configuration and settings |
| Monitoring, Automation and Operational Efficiency | 5% | - Monitoring and alerting configuration - Automation workflows and tools - Operational process optimization |
| Business Continuity and Disaster Recovery | 15% | - BCDR testing and validation - Replication and recovery configuration - Disaster recovery strategy implementation - Failover and failback operations |
| Advanced Platform Configuration and Troubleshooting | 25% | - Prism Central and Prism Element configuration - Integration with third-party systems - Cluster management, expansion and maintenance - Security configuration and compliance - API and CLI-based operations |
| Network Performance and Security | 20% | - Implement and analyze Flow security policies - Network troubleshooting and optimization - Tune overlay networking and traffic flow - Optimize physical and virtual network configurations |
>> Latest NCM-MCI-6.10 Test Preparation <<
To keep pace with the times, we believe science and technology can enhance the way people study on our NCM-MCI-6.10 exam materials. Especially in such a fast-pace living tempo, we attach great importance to high-efficient learning our NCM-MCI-6.10 Study Guide. Therefore, our NCM-MCI-6.10 study materials base on the past exam papers and the current exam tendency, and design such an effective simulation function to place you in the real exam environment.
NEW QUESTION # 13
Due to new security requirements, an administrator has been tasked with updating the security settings for user accounts within Prism Element on Cluster 1.
An SSL Certificate Signing Request with Subject Alternative Name should be generated for submission to the security team's Certificate Authority with the following details:
countryName = US
stateOrProvinceName = North Carolina
localityName = Durham
organizationName = ACME
organizationalUnitName = Infrastructure
commonName = prism_element.ACME.org
emailAddress = administrator@ACME.org
Alternate names = cvm1.ACME.org, cvm2.ACME.org, cvm3.ACME.org
Encryption: RSA 2048, sha256
When the Certificate Signing Request is generated, place a copy of both the .cnf file and the .csr file on the desktop named 'prism_element_acme.cnf' and 'prism_element_acme.csr' Save a copy of the command(s) used for this scenario to a new file on the desktop named "Task 5.txt".
Note: You must copy and paste the command(s) and output from SSH to the "Task 5.txt" file to achieve all points available.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to generate the Certificate Signing Request (CSR) on Cluster 1.
This entire process is performed from an SSH session connected to a CVM (Controller VM) on Cluster 1.
1. Access Cluster 1 CVM
* From Prism Central, navigate to Hardware > Clusters and click on Cluster 1 to open its Prism Element (PE) interface.
* In the Cluster 1 PE, navigate to Hardware > CVMs to find the IP address of any CVM in the cluster.
* Use an SSH client (like PuTTY) to connect to the CVM's IP address.
* Log in with the admin user and password.
2. Create the Configuration File (.cnf)
To include the Subject Alternative Names (SANs), you must first create a configuration file.
* In the CVM's command line, create the .cnf file using a text editor:
vi prism_element_acme.cnf
* Press i to enter "Insert" mode.
* Paste the following text exactly into the editor:
Ini, TOML
[ req ]
default_bits = 2048
distinguished_name = req_distinguished_name
req_extensions = v3_req
prompt = no
[ req_distinguished_name ]
C = US
ST = North Carolina
L = Durham
O = ACME
OU = Infrastructure
CN = prism_element.ACME.org
emailAddress = administrator@ACME.org
[ v3_req ]
subjectAltName = @alt_names
[ alt_names ]
DNS.1 = cvm1.ACME.org
DNS.2 = cvm2.ACME.org
DNS.3 = cvm3.ACME.org
* Press Esc to exit "Insert" mode, then type :wq and press Enter to save and quit vi.
3. Generate the CSR and Key
* Run the following openssl command. This command uses the .cnf file to generate the new CSR (.csr) and a corresponding private key (.key), applying the sha256 encryption as requested.
Bash
openssl req -new -nodes -out prism_element_acme.csr -keyout prism_element_acme.key -config prism_element_acme.cnf -sha256
* The command will output the following, confirming the key generation:
* Generating a 2048 bit RSA private key
* ...................+++++
* ..................................+++++
* writing new private key to 'prism_element_acme.key'
* -----
4. Save Files to the Desktop
You will now copy the contents of the generated files from the CVM to your desktop.
* For Task 5.txt (Commands and Output):
* Open a new Notepad file on the desktop.
* Copy and paste all the commands you ran in the SSH session and their full output (as shown in steps 2 and 3) into this file.
* Save the file on the desktop as Task 5.txt.
* For prism_element_acme.cnf:
* In the CVM SSH session, display the file's content:
cat prism_element_acme.cnf
* Copy the entire text output (starting from [ req ]).
* Open a new Notepad file on the desktop.
* Paste the content and save the file as prism_element_acme.cnf.
* For prism_element_acme.csr:
* In the CVM SSH session, display the file's content:
cat prism_element_acme.csr
* Copy the entire text output, including the -----BEGIN CERTIFICATE REQUEST----- and ----- END CERTIFICATE REQUEST----- lines.
* Open a new C:\Users\admin\Desktop\Notepad file on the desktop.
* Paste the content and save the file as prism_element_acme.csr.
NEW QUESTION # 14
An administrator is experiencing an unidentified issue which is causing inode exhaustion on CVMs in Cluster
1. The time between receiving alerts and exhaustion is too short; the administrator needs to lower the alert thresholds to allow more time to clean up inodes until the issue has been identified and resolution implemented.
From Prism Element, modify the appropriate alert policy setting critical threshold for Cluster 1 to 60% and warning threshold to 45%. Ensure the check runs every minute and is not resolved without administrator action.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to modify the alert policy from the Prism Element (PE) interface for Cluster 1.
1. Access Cluster 1 Prism Element
* From the main Prism Central dashboard, navigate to Hardware > Clusters.
* Find Cluster 1 in the list and click its name. This will open the specific Prism Element login page for that cluster.
* Log in to Cluster 1's Prism Element interface.
2. Modify the Alert Policy
* In the Cluster 1 PE interface, click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Alert Policies.
* In the search bar, type inode to find the correct policy.
* Select the checkbox for the policy named cvm_inode_usage_high.
* Click the Update button.
* In the "Update Alert Policy" dialog, configure the following settings:
* Warning Threshold (%): Change the value to 45.
* Critical Threshold (%): Change the value to 60.
* Check Interval (Secs): Change the value to 60 (to run the check every minute).
* Auto Resolve: Uncheck this box (to ensure the alert is not resolved without administrator action).
* Click Save.
NEW QUESTION # 15
An administrator needs to configure a new write-intensive MS-SQL VM on Cluster 1.
VM specifications:
* vCPU: 12
* vRAM: 128GB
* Storage: 100 GB OS, 750 GB Data
Create the VM and any objects needed in the current environment to meet requirements, maximizing performance for the production environment. Include NEWSQL in the name of any new objects.
Production environment:
* 4 nodes
* Each node has two 8-core CPUs
* Each node has 1024 GB RAM
* Storage: 4 × 7.16 TB SSD Disks and 8 × 8 TB HDD disks
Make sure the VM is configured for maximum performance for the production environment.
Note: Network configuration is not required at this time. Do not power on the VM.
Answer:
Explanation:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to create the high-performance SQL VM on Cluster 1.
This task requires two phases: first, creating a new all-flash storage container, and second, creating the VM with a specific vNUMA and disk controller configuration for maximum performance.
1. Access Cluster 1 Prism Element
* From the main Prism Central dashboard, navigate to Hardware > Clusters.
* Find Cluster 1 in the list and click its name. This will open the specific Prism Element login page for that cluster.
* Log in to Cluster 1's Prism Element interface.
2. Create the All-Flash Storage Container
To maximize performance for a "write-intensive" workload on a hybrid cluster, the data and log disks must be placed on an all-flash container.
* In the Cluster 1 PE interface, click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Storage.
* Click the + Storage Container button.
* Fill in the basic details:
* Name: NEWSQL_Flash_Container
* Click Advanced Settings.
* Scroll down to the Storage Tier section.
* Select the SSD radio button. This pins all data in this container to the SSD tier, ensuring all-flash performance.
* Click Save.
3. Create and Configure the VM
Now, create the VM, applying vNUMA and multi-SCSI controller best practices.
* From the main PE dashboard, navigate to the VM view.
* Click the + Create VM button.
* Enter the compute details. This configuration is critical for vNUMA performance, as it tells the VM's guest OS about the underlying physical NUMA topology (2 CPUs with 8 cores each).
* Name: NEWSQL_VM
* vCPUs: 12
* Number of Sockets: 2
* Cores per vCPU: 6 (This creates a 2-socket, 6-core VM, totaling 12 vCPUs)
* Memory: 128 GB
* Scroll down to the Disks section and add the OS disk:
* Click + Add New Disk.
* Storage Container: Select the default (hybrid) container.
* Size: 100 GB
* Bus: SCSI
* Device Index: 0 (This will be scsi.0)
* Click Add.
* Add the Data disk (on its own controller for parallel processing):
* Click + Add New Disk.
* Storage Container: Select NEWSQL_Flash_Container.
* Size: 750 GB
* Bus: SCSI
* Device Index: 1 (This creates a new controller, scsi.1)
* Click Add.
* Add a Log disk (on its own controller, a best practice for "write-intensive" SQL):
* Click + Add New Disk.
* Storage Container: Select NEWSQL_Flash_Container.
* Size: 100 GB (A common size for a log disk)
* Bus: SCSI
* Device Index: 2 (This creates a third controller, scsi.2)
* Click Add.
* Review the configuration: You should now have three disks attached, each on a separate controller (scsi.
0, scsi.1, scsi.2). This provides the maximum I/O performance.
* Ensure the Power on VM after creation box is unchecked.
* Click Save.
Topic 1, Performance Based Questions Set 1
Environment
You have been provisioned a dedicated environment for your assessment which includes the following:
Initial Steps
* When you first log into Prism Central or Prism Element you may see the EULA screen. Accept the EULA with any name and then disable Pulse.
* To access Prism Element, the pass-through from Prism Central
(Infrastructure\Hardware\Clusters\cluster-x\Launch Prism Element) works better than directly using the external IP:9440.
Workstation
* Windows Server 2019
* All software/tools/etc to perform the required tasks
* Nutanix Documentation and whitepapers can be found in Desktop\Files\Documentation and Desktop\Files\Documentation 6.10
* Note that the Workstation is the system you are currently logged into
* Windows Server 2019
* All software/tools/etc to perform the required tasks
* Nutanix Documentation and whitepapers can be found in Desktop\Files\Documentation and Desktop\Files\Documentation 6.10
* Note that the Workstation is the system you are currently logged into Nutanix Cluster
* There are two clusters provided, connected to one Prism Central. The connection information for the relevant cluster will be displayed to the right of the question. Please make sure you are working on the correct cluster for each item. Please ignore any licensing violations.
Important Notes
* If the text is too small and hard to read, or you cannot see all of the GUI, you can increase/decrease the zoom of the browser with CTRL + and CTRL - (the plus and minus keys).
Prism Central Web Console
* admin / ykZUCJMER7V*
* nutanix / UJ2xE!DEXGY
Cluster 1
* CVM external IP: 34.53.118.63
* CVM DR IP: 172.30.0.6
* admin / 9Fw0B!3QH4X)
* nutanix / GNP*FE2504XWZ
* root / KR*6HY0z5E8
Cluster 2
* CVM external IP: 34.82.155.5
* CVM DR IP: 172.30.0.4
* admin / 5*K30fA76X
* nutanix / N*3F%1ME!Z7T9
NEW QUESTION # 16
Task 3
An administrator needs to create a report named VMs_Power_State that lists the VMs in the cluster and their basic details including the power state for the last month.
No other entities should be included in the report.
The report should run monthly and should send an email to admin@syberdyne.net when it runs.
Generate an instance of the report named VMs_Power_State as a CSV and save the zip file as Desktop\Files\VMs_Power_state.zip Note: Make sure the report and zip file are named correctly. The SMTP server will not be configured.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
To create a report named VMs_Power_State that lists the VMs in the cluster and their basic details including the power state for the last month, you can follow these steps:
Log in to Prism Central and click on Entities on the left menu.
Select Virtual Machines from the drop-down menu and click on Create Report.
Enter VMs_Power_State as the report name and a description if required. Click Next.
Under the Custom Views section, select Data Table. Click Next.
Under the Entity Type option, select VM. Click Next.
Under the Custom Columns option, add the following variables: Name, Cluster Name, vCPUs, Memory, Power State. Click Next.
Under the Time Period option, select Last Month. Click Next.
Under the Report Settings option, select Monthly from the Schedule drop-down menu. Enter admin@syberdyne.net as the Email Recipient. Select CSV as the Report Output Format. Click Next.
Review the report details and click Finish.
To generate an instance of the report named VMs_Power_State as a CSV and save the zip file as Desktop\Files\VMs_Power_state.zip, you can follow these steps:
Log in to Prism Central and click on Operations on the left menu.
Select Reports from the drop-down menu and find the VMs_Power_State report from the list. Click on Run Now.
Wait for the report to be generated and click on Download Report. Save the file as Desktop\Files\VMs_Power_state.zip.
1.Open the Report section on Prism Central (Operations > Reports)
2.Click on the New Report button to start the creation of your custom report
3.Under the Custom Views section, select Data Table
4.Provide a title to your custom report, as well as a description if required.
5.Under the Entity Type option, select VM
6.This report can include all as well as a selection of the VMs
7.Click on the Custom Columns option and add the below variables:
a.Name - Name of the listed Virtual Machine
b.vCPUs - A combination of the vCores and vCPU's assigned to the Virtual Machine c.Memory - Amount of memory assigned to the Virtual Machine d.Disk Capacity - The total amount of assigned virtual disk capacity e.Disk Usage - The total used virtual disk capacity f.Snapshot Usage - The total amount of capacity used by snapshots (Excluding Protection Domain snapshots)
8.Under the Aggregation option for Memory and Disk Usage accept the default Average option
9.Click on the Add button to add this custom selection to your report
10.Next click on the Save and Run Now button on the bottom right of the screen
11.Provide the relevant details on this screen for your custom report:
12.You can leave the Time Period For Report variable at the default of Last 24 Hours
13.Specify a report output of preference (PDF or CSV) and if required Additional Recipients for this report to be mailed to. The report can also simply be downloaded after this creation and initial run if required
14.Below is an example of this report in a CSV format:
NEW QUESTION # 17
Task 13
An administrator found a CentOS VM, Cent_Down, on the cluster with a corrupted network stack. To correct the issue, the VM will need to be restored from a previous snapshot to become reachable on the network again.
VM credentials:
Username: root
Password: nutanix/4u
Restore the VM and ensure it is reachable on the network by pinging 172.31.0.1 from the VM.
Power off the VM before proceeding.
Answer:
Explanation:
See the Explanation for step by step solution.
Explanation:
To restore the VM and ensure it is reachable on the network, you can follow these steps:
Log in to the Web Console of the cluster where the VM is running.
Click on Virtual Machines on the left menu and find Cent_Down from the list. Click on the power icon to power off the VM.
Click on the snapshot icon next to the power icon to open the Snapshot Management window.
Select a snapshot from the list that was taken before the network stack was corrupted. You can use the date and time information to choose a suitable snapshot.
Click on Restore VM and confirm the action in the dialog box. Wait for the restore process to complete.
Click on the power icon again to power on the VM.
Log in to the VM using SSH or console with the username and password provided.
Run the command ping 172.31.0.1 to verify that the VM is reachable on the network. You should see a reply from the destination IP address.
Go to VMS from the prism central gui
Select the VMand go to More -> Guest Shutdown
Go to Snapshots tab and revert to latest snapshot available
power on vm and verify if ping is working
NEW QUESTION # 18
......
Nowadays, we live so busy every day. Especially for some businessmen who want to pass the NCM-MCI-6.10 exam and get related certification, time is vital importance for them, they may don’t have enough time to prepare for their exam. Some of them may give it up. But our NCM-MCI-6.10 guide tests can solve these problems perfectly, because our study materials only need little hours can be grasped. Believing in our NCM-MCI-6.10 Guide tests will help you get the certificate and embrace a bright future. Time and tide wait for no man. Come to buy our test engine.
NCM-MCI-6.10 Accurate Prep Material: https://www.dumpleader.com/NCM-MCI-6.10_exam.html
P.S. Free 2026 Nutanix NCM-MCI-6.10 dumps are available on Google Drive shared by Dumpleader: https://drive.google.com/open?id=1N90Ig6NdnJrKu5O3kF3bYnTVjyOEvDwm