We have designed a chat window below the web page. Once you want to ask some questions about the LEED-AP-BD-C training engine, you can click the little window. Then you just need to click the buttons after writing your email address and your questions about the LEED-AP-BD-C Exam Questions. Our back operation system will soon receive your email; then you will get a quick feedback on the LEED-AP-BD-C practice braindumps from our online workers.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
| Topic 7 |
|
| Topic 8 |
|
>> USGBC LEED-AP-BD-C Best Vce <<
When your life is filled with enriching yourself, you will feel satisfied with your good change. Our LEED-AP-BD-C exam questions are designed to stimulate your interest in learning so that you learn in happiness. And our LEED-AP-BD-C praparation materials are applied with the latest technologies so that you can learn with the IPAD, phone, laptop and so on. Try to believe in yourself. You also can become social elite under the guidance of our LEED-AP-BD-C Study Guide.
NEW QUESTION # 430
Which of the following is an example of a nonroof measure for Sustainable Sites Credit, Heat Island Reduction?
Answer: D
Explanation:
Explanation
A vegetated shading structure is an example of a nonroof measure for Sustainable Sites Credit, Heat Island Reduction. The heat island effect is the phenomenon of urban areas having higher air temperatures than surrounding rural areas due to the absorption and emission of heat by human-made surfaces, such as buildings, roads, and pavements. The heat island effect can have negative impacts on the environment, human health, and energy consumption. One of the strategies to reduce the heat island effect is to use nonroof measures that provide shade, reflectivity, or evapotranspiration for at least 50% of the site hardscape, such as parking lots, walkways, plazas, and courtyards1. A vegetated shading structure is a type of nonroof measure that consists of a trellis or pergola that supports climbing plants or vines that provide shade and cooling for the underlying surface. A vegetated shading structure can also enhance the aesthetic and ecological value of the site2.
The other options are not examples of nonroof measures for Sustainable Sites Credit, Heat Island Reduction. A playground with artificial turf is not a nonroof measure, but a roof measure, as it is considered as part of the building envelope. Artificial turf is also not a compliant roof measure, as it does not meet the minimum solar reflectance index (SRI) or vegetated roof requirements1. A shade structure with a three-year aged SRI value of
0.2 is not a compliant nonroof measure, as it does not meet the minimum SRI value of 29 for nonroof surfaces1. A paving material with a three-year aged SRI value of 0.2 is also not a compliant nonroof measure, as it does not meet the minimum SRI value of 29 for nonroof surfaces1.
References:
*LEED v4 Reference Guide for Building Design and Construction, Sustainable Sites Credit: Heat Island Reduction, page 1281
*Heat Island Reduction | U.S. Green Building Council2
NEW QUESTION # 431
Under Energy and Atmosphere Prerequisite, Fundamental Commissioning and Verification, a current facilities requirements and operations and maintenance plan must contain which information necessary to operate the building efficiently?
Answer: B
Explanation:
A current facilities requirements and operations and maintenance plan must contain any changes in schedules or setpoints for different seasons, days of the week, and times of day. This is to ensure that the building systems are operating efficiently and according to the design intent. The other options are too limited or too specific and do not cover all the possible variations in schedules or setpoints.
NEW QUESTION # 432
A commercial office building with a footprint of 70,000 ft2 (6 503.2 m2) has an overall site area of 200,000 ft2 (18 580.6 m2). The project design includes 15,000 ft2 (1 393.5 m2) of pedestrian oriented hardscape and 18,000 ft2 (1 672.3 m2) of vegetated open space. Which of the following is necessary to satisfy the requirement for the outdoor space to be physically accessible when calculating the Sustainable Sites Credit, Open Space?
Answer: D
Explanation:
A pedestrian-oriented paving or turf area with physical site elements that accommodate outdoor social activities is necessary to satisfy the requirement for the outdoor space to be physically accessible when calculating the Sustainable Sites Credit, Open Space. This is because the outdoor space must be designed to encourage regular use by occupants and visitors1. A garden space dedicated to industrial food production for use by local communities may not be accessible to the building occupants and visitors2. A garden space with only one vegetation type and species during the summer for visual interest does not meet the requirement of having two or more types of vegetation or overhead vegetated canopy1. A dark paving area with site elements to encourage parking near wetlands or naturally designed ponds is not considered as pedestrian-oriented hardscape and may have negative impacts on the natural environment3.
References:
* Open Space, p. 1
* NC-v4 SSc3: Open space, p. 2
* LEED V5for Building Design and Construction, p. 72
NEW QUESTION # 433
In order to comply with Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies, Option 2, Additional Enhanced Air Quality Strategies:
Answer: A
Explanation:
To comply withLEED BD+C Indoor Environmental Quality (IEQ) Credit: Enhanced Indoor Air Quality Strategies, Option 2, a project must implementat least twoof the following enhanced air quality strategies:
Use of an outdoor airflow measurement deviceto monitor andmeasure at least 90% of the outdoor air intake flowto ensure proper ventilation.
Advanced filtration systems(such as CEN Class F7 or MERV 13 filters) for mechanically ventilated buildings.
Carbon dioxide (CO₂) monitoringin densely occupied spaces, with alerts for elevated CO₂ levels.
Entryway systems(such as walk-off mats) at all regularly used building entrances to reduce dirt and contaminants.
Option Dcorrectly identifiesoutdoor airflow measurementas one of theacceptable strategiesunderOption 2.
(Source: Official LEED BD+C Reference Manual)
NEW QUESTION # 434
Which of the following strategies will aid in reducing indoor water use?
Answer: B
Explanation:
According to the LEED v4: Building Design + Construction Guide, one of the strategies to reduce indoor water use is to optimize the consumption of showerheads by selecting fixtures that have a flow rate lower than the baseline of 2.0 gallons per minute (gpm) at 80 psi, or a local equivalent for projects outside the U.S. This can help the project achieve the Water Efficiency Prerequisite, Indoor Water Use Reduction, and the Water Efficiency Credit, Indoor Water Use Reduction, by reducing the aggregate water consumption from plumbing fixtures and fittings by at least 20% from the baseline1.
The other choices are not strategies to reduce indoor water use, because:
* Designing drip irrigation for landscape is a strategy to reduce outdoor water use, not indoor water use1.
* Using high-efficiency HVAC systems is a strategy to reduce energy use, not water use, although it may have some indirect water savings by reducing the cooling tower water use2.
* Excluding janitor closets in the building is not a feasible or practical strategy, as janitor closets are necessary for cleaning and maintenance purposes, and may also be required by codes or standards3.
References: LEED v4: Building Design + Construction Guide, Water Efficiency Prerequisite, Indoor Water Use Reduction, Requirements1; LEED v4: Building Design + Construction Guide, Water Efficiency Credit, Indoor Water Use Reduction, Requirements1; LEED v4: Building Design + Construction Guide, Energy and Atmosphere Credit, Optimize Energy Performance, Requirements2; LEED v4: Building Design + Construction Guide, Indoor Environmental Quality Credit, Green Cleaning - High-Performance Cleaning Program, Requirements3
NEW QUESTION # 435
......
We make the commitment that if you fail to pass your exam by using LEED-AP-BD-C study materials of us, we will give you refund. We are pass guarantee and money back guarantee. In addition, LEED-AP-BD-C exam dumps are high-quality, and you can improve your efficiency if you use them. LEED-AP-BD-C exam materials contain almost all of the knowledge points for the exam, and you master the major knowledge for the exam as well as improve your professional ability in the process of learning. In order to let you obtain the latest information for the exam, we offer you free update for one year, and the update version for LEED-AP-BD-C Exam Dumps will be sent to your email automatically.