International Code Council인증 93-Tall-Mass-Timber-Buildings시험을 한방에 편하게 통과하여 자격증을 취득하려면 시험전 공부가이드가 필수입니다. ITDumpsKR에서 연구제작한 International Code Council인증 93-Tall-Mass-Timber-Buildings덤프는International Code Council인증 93-Tall-Mass-Timber-Buildings시험을 패스하는데 가장 좋은 시험준비 공부자료입니다. ITDumpsKR덤프공부자료는 엘리트한 IT전문자들이 자신의 노하우와 경험으로 최선을 다해 연구제작한 결과물입니다.IT인증자격증을 취득하려는 분들의 곁은ITDumpsKR가 지켜드립니다.

International Code Council 93-Tall-Mass-Timber-Buildings Exam Syllabus Topics:

SectionObjectives
Structural Inspection- Connections and fastening systems
- Structural loads and related code requirements
- Mass timber structural elements
Fire Protection and Fire-Resistance- Fire protection systems and related provisions
- Fire-resistance requirements
- Noncombustible protection and protection of mass timber elements
Special Inspection Requirements- Special inspection procedures for tall mass timber buildings
- Inspector duties and responsibilities
- Inspection of connections and protective materials
Tall Mass Timber Building Code Provisions- International Building Code requirements for tall mass timber construction
- Types IV-A, IV-B and IV-C construction
- Mass timber materials and construction requirements
Code Compliance and Related Requirements- Energy code requirements applicable to mass timber buildings
- Documentation and verification of compliance
- Sound transmission requirements
Construction Fire Safety- Construction-phase fire safety requirements
- Protection of mass timber during construction
- International Fire Code requirements

>> 93-Tall-Mass-Timber-Buildings합격보장 가능 공부자료 <<

93-Tall-Mass-Timber-Buildings합격보장 가능 공부자료 최신 시험대비자료

International Code Council 93-Tall-Mass-Timber-Buildings인증덤프는 최근 출제된 실제시험문제를 바탕으로 만들어진 공부자료입니다. International Code Council 93-Tall-Mass-Timber-Buildings 시험문제가 변경되면 제일 빠른 시일내에 덤프를 업데이트하여 최신버전 덤프자료를International Code Council 93-Tall-Mass-Timber-Buildings덤프를 구매한 분들께 보내드립니다. 시험탈락시 덤프비용 전액환불을 약속해드리기에 안심하시고 구매하셔도 됩니다.

최신 Special Inspector 93-Tall-Mass-Timber-Buildings 무료샘플문제 (Q76-Q81):

질문 # 76
In Type IV-C construction, a connection between two members of the primary structural frame supporting a floor is required to be protected to achieve a minimum fire-resistance rating of:

정답:A

설명:
The required minimum rating is two hours. Under 2021 IBC Table 601, the primary structural frame in Type IV-C construction must provide a two-hour fire-resistance rating. A structural connection joining members of that frame cannot be permitted to fail before the members it connects; consequently, the connection must remain functional for the same required period.
The protection requirement applies to the complete connection assembly. This includes steel plates, hangers, bolts, screws, dowels, fasteners, welds, bearing regions, and portions of the connected timber that form part of the connection. Compliance can be achieved through tested construction, calculated wood cover, Type X gypsum protection, another approved noncombustible system, or a combination documented by the registered design professional.
Option A is insufficient because it would leave a one-hour weakness in a two-hour structural load path.
Option B similarly falls short of the required Table 601 rating. Option D is the Type IV-A primary-frame rating and is not required for the stated Type IV-C condition.
The special inspector must verify protective-cover dimensions and installation before connection hardware becomes concealed, including any project-specific inspection required for calculated wood-cover protection.
References/Topics: 2021 IBC Table 601 and Section 2304.10.1; AWC Fire Design Specification, protection of structural connections.


질문 # 77
Refer to the exhibit by clicking on the EXHIBIT button above.

Given: The connections between the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, and wood cover is designed per AWC Technical Report 10 to provide the entire 2 hours of protection.
The bearing area between the CLT and glulam is the minimum required.
What are the minimum dimensions, in inches, for the wood block shown in red?

정답:B

설명:
Under the illustrated connection detail, the minimum wood-block dimensions are 3 inches by 3 inches.
Therefore, option C is correct.
The block is part of the sacrificial wood-cover system used to protect the connection for the full two-hour fire- resistance period. It must provide sufficient timber beyond the protected connection region to account for calculated charring and the increased exposure that can develop at the interface between abutting wood members. Because the problem states that the CLT-to-glulam bearing area is already the minimum required, the primary members do not provide surplus material that can be credited as additional protection at that edge.
AWC connection-fire-design guidance requires the protective geometry to remain effective after the calculated char front advances. Char contraction can open a gap at abutting edges and expose material deeper in the connection than would occur on an uninterrupted planar surface. The 3-inch-by-3-inch block maintains the required protective envelope for the stated two-hour condition.
This dimension is specific to the illustrated configuration and assumptions; it is not a universal minimum for every mass timber connection. The inspector must verify the approved detail rather than substitute nominal blocking based solely on field availability.
References/Topics: AWC Technical Report 10; AWC Fire Design Specification provisions for wood-cover protection and char contraction at abutting members.


질문 # 78
Each of the following is true for special inspection of mass timber construction except:

정답:C

설명:
Option A is the false statement. Under 2021 IBC Table 1705.5.3, bolted connections require periodic special inspection, not continuous special inspection.
The remaining three statements correspond directly to items contained in the table. Concealed connections are subject to periodic inspection. Erection of mass timber construction is also periodically inspected. For threaded fasteners, the inspector must periodically verify the use of pre-drilled holes where the approved design or manufacturer's installation requirements call for them.
The distinction between periodic and continuous inspection is fundamental. Periodic inspection means the special inspector observes the work at appropriate intervals sufficient to verify compliance. Continuous inspection requires the inspector to be present continuously during the performance of the regulated work.
Table 1705.5.3 reserves continuous inspection for the particularly installation-sensitive condition involving adhesive anchors installed horizontally or upwardly inclined to resist sustained tension loads.
For bolted connections, periodic inspection remains technically substantive. The inspector should verify bolt size and type, hole preparation, connection geometry, washers and nuts, required tightening, member condition, edge and end distances, and conformity with the approved structural drawings.
References/Topics: 2021 IBC Section 1705.5.3; Table 1705.5.3, Required Special Inspections of Mass Timber Construction.


질문 # 79
Refer to the figure by clicking on the EXHIBIT button above.


In Type IV-B construction, based on a 900 sq. ft. floor area, a 30 ' room width, and a 12 in. x 18 in. beam as shown in the Figure, the maximum length of the unprotected portion of the mass timber ceiling (dimension X) is _____ feet.

정답:D

설명:
Section 602.4.2.2.2 permits unprotected mass timber ceilings in Type IV-B construction to equal no more than 20 percent of the floor area , and the code expressly states that attached beams are included when determining that exposed ceiling area.
The floor area is 900 square feet:
20% × 900 = 180 sq. ft. maximum exposed area .
The exposed 12-inch × 18-inch beam extends across the 30-foot room. Its three exposed surfaces consist of the 12-inch-wide bottom and two 18-inch-deep sides:
30 ft × (1 ft + 1.5 ft + 1.5 ft) = 120 sq. ft.
Because the attached beam counts against the ceiling exposure allowance, only:
180 # 120 = 60 sq. ft.
remains available for the exposed ceiling itself.
The exposed ceiling extends across the 30-foot room width, so:
30 ft × X = 60 sq. ft.
Therefore:
X = 2 ft .
Option A is correct. Ignoring the beam surfaces would overstate the permitted ceiling exposure and would contradict the explicit IBC requirement that attached beams be included in the exposed ceiling calculation.
References/Topics: 2021 IBC Section 602.4.2.2.2, Exception 1.1; Type IV-B exposed ceiling and attached- beam area calculations.


질문 # 80
According to UL Fire Resistance Directory, a "finish rating" is the time:

정답:A

설명:
Option C correctly states the fundamental UL finish-rating criterion. UL defines a finish rating for assemblies containing combustible wood structural supports as the elapsed fire-exposure time at which the wood member immediately behind the protective membrane reaches the prescribed temperature-rise threshold.
More precisely, UL uses two criteria: an average temperature rise of 250°F or an individual-point temperature rise of 325°F , measured on the plane of the wood nearest the fire, typically between the gypsum membrane and the wood stud or joist. The question asks for the principal definition, which is the 250° F temperature-rise criterion; therefore, option C is correct. Option D incorrectly treats the 325°F individual- point limit as the sole definition.
Options A and B confuse a finish rating with "assigned protection time." IBC Tables 722.6 and 722.7 provide calculated contribution values for specified protective materials, but those assigned values are not themselves UL finish ratings.
This distinction matters in mass timber fire design because membrane contribution, thermal separation, structural fire resistance, and finish rating are related but not interchangeable concepts.
References/Topics: UL Fire Resistance Directory terminology; finish rating; average 250°F and individual
325°F temperature-rise criteria.


질문 # 81
......

우리ITDumpsKR 에서 제공하는 학습가이드에는 IT전문가들이 만들어낸 시험대비 자료들과International Code Council 93-Tall-Mass-Timber-Buildings인증시험의 완벽한 문제와 답들입니다. 그리고 우리ITDumpsKR에서는 IT업계에서의 높은 신뢰감으로 여러분들한테 100%보장을 드립니다. 우리에 믿음을 드리기 위하여International Code Council 93-Tall-Mass-Timber-Buildings관련자료의 일부분 문제와 답 등 샘플을 무료로 다운받아 체험해볼수 있게 제공합니다.