International Code Council M2 Exam Syllabus Topics:

SectionObjectives
General Administration and Mechanical Inspection Practice- Code enforcement procedures and inspector responsibilities
  • 1. Permit requirements and inspections
    • 2. Documentation and reporting
      Mechanical Appliances and Equipment- Boilers, furnaces, and water heaters
      • 1. Installation and inspection requirements
        • 2. Safety controls and venting
          Ventilation and Indoor Air Quality- Ventilation requirements
          • 1. Exhaust systems
            • 2. Outdoor air intake requirements
              Mechanical Code (IMC) Fundamentals- International Mechanical Code application
              • 1. Scope and definitions
                • 2. General regulations
                  HVAC Systems and Equipment- Heating and cooling systems
                  • 1. Duct systems design and installation
                    • 2. Air handling units and system components
                      Fuel Gas Systems- Gas piping and appliance installation
                      • 1. Combustion air requirements
                        • 2. Gas safety and testing

                          >> M2無料過去問 <<

                          便利なM2無料過去問 & 合格スムーズM2トレーニング資料 | 実際的なM2模擬対策 Commercial Mechanical Inspector

                          あなたは今やはりM2試験に悩まされていますか?長い時間M2試験を取り組んいる弊社はあなたにM2練習問題を提供できます。あなたはM2試験に興味を持たれば、今から行動し、M2練習問題を買いましょう。M2試験に合格するために、M2練習問題をよく勉強すれば、いい成績を取ることが難しいことではありません。つまりM2練習問題はあなたの最も正しい選択です。

                          International Code Council Commercial Mechanical Inspector 認定 M2 試験問題 (Q45-Q50):

                          質問 # 45
                          The optional integral clearance reduction system is designed to meet which NFPA standard?

                          正解:D

                          解説:
                          Based on the specification sheet shown in the exhibit, the design features state that the optional integral clearance reduction system meets the requirements of NFPA 96 . Therefore, the correct answer is D .


                          質問 # 46
                          The minimum size for access openings for fire dampers shall be:

                          正解:A

                          解説:
                          The IMC requires access openings for fire dampers to be of a size that allows maintenance and resetting of the damper . The code does not set the answer as same-as-duct, half-diagonal, or a universal 12-inch by 12- inch opening. So Option C is correct.


                          質問 # 47
                          When a furnace is installed in a 66-inch-high attic, the maximum distance from the passageway access to the furnace shall be _____ ft., measured along the centerline of the passageway.

                          正解:D

                          解説:
                          ICC mechanical access provisions for appliances in attics require the passageway to be not more than 20 feet in length , measured along the centerline of the passageway from the opening to the appliance, where the attic passageway is the standard reduced-height access condition. Since the attic height given is 66 inches, the standard maximum length applies, so Option C is correct. The 50-foot allowance applies only under a different exception where the passageway is unobstructed and at least 6 feet high for its entire length.


                          質問 # 48
                          Given: A recirculating industrial direct-fired makeup air heater has a rated input of 200,000 Btu/h .
                          Ventilation air is supplied by separate mechanical means.
                          Outside ventilation air shall be provided to supply at least _____ CFM.

                          正解:C

                          解説:
                          The applicable provision requires direct-fired industrial air heaters to supply outside ventilation air at a rate of not less than 4 cfm per 1,000 Btu/h of rated input where ventilation air is provided by separate mechanical means. For 200,000 Btu/h , the required outside air is:
                          200,000 ÷ 1,000 = 200
                          200 × 4 = 800 cfm
                          So the correct answer is C


                          質問 # 49
                          Indoor combustion air shall be provided within:

                          正解:A

                          解説:
                          For indoor combustion air openings, one opening must commence within 12 inches of the top of the enclosure and one within 12 inches of the bottom . That corresponds to 1 foot of the ceiling and 1 foot of the floor , so Option A is correct.


                          質問 # 50
                          ......