International Code Council 93-Tall-Mass-Timber-Buildings Exam Syllabus Topics:

SectionObjectives
Construction Fire Safety- Construction-phase fire safety requirements
- International Fire Code requirements
- Protection of mass timber during construction
Special Inspection Requirements- Special inspection procedures for tall mass timber buildings
- Inspector duties and responsibilities
- Inspection of connections and protective materials
Fire Protection and Fire-Resistance- Fire-resistance requirements
- Noncombustible protection and protection of mass timber elements
- Fire protection systems and related provisions
Tall Mass Timber Building Code Provisions- Mass timber materials and construction requirements
- International Building Code requirements for tall mass timber construction
- Types IV-A, IV-B and IV-C construction
Structural Inspection- Structural loads and related code requirements
- Connections and fastening systems
- Mass timber structural elements
Code Compliance and Related Requirements- Energy code requirements applicable to mass timber buildings
- Documentation and verification of compliance
- Sound transmission requirements

>> 93-Tall-Mass-Timber-Buildings関連日本語内容 <<

試験の準備方法-素敵な93-Tall-Mass-Timber-Buildings関連日本語内容試験-最新の93-Tall-Mass-Timber-Buildings試験問題解説集

93-Tall-Mass-Timber-Buildingsトレーニング資料のPDFバージョンは読みやすく、覚えやすく、印刷リクエストをサポートしているため、紙で印刷して練習することができます。練習資料のソフトウェアバージョンは、シミュレーションテストシステムをサポートし、セットアップの時間を与えることには制限がありません。

International Code Council 93-Tall-Mass-Timber-Buildings 認定 93-Tall-Mass-Timber-Buildings 試験問題 (Q54-Q59):

質問 # 54
Disregarding footnotes, which of the following is true regarding fire-resistance ratings of building elements per the International Building Code Table 601?

正解:A

解説:
When the footnotes are disregarded, the fire-resistance ratings assigned to the principal building elements of Type IV-A construction correspond to those of Type I-A construction . Option A is therefore correct.
IBC Table 601 assigns both Type I-A and Type IV-A a 3-hour rating for the primary structural frame , 3 hours for exterior and interior bearing walls, 2 hours for floor construction and associated secondary structural members , and 1½ hours for roof construction and associated secondary structural members
. Interior nonbearing walls and partitions are generally rated zero by Table 601 unless another code provision requires a rating. Exterior nonbearing walls are governed separately based on fire separation distance.
The similarity in Table 601 ratings does not mean Type I-A and Type IV-A are otherwise equivalent construction types. Type I-A relies principally on noncombustible structural construction, whereas Type IV-A permits mass timber subject to the substantial noncombustible protection requirements of Section 602.4.1.
Types II-A, III-A, IV-C, and IV-HT have materially different Table 601 requirements, so options B, C, and D do not provide a complete rating match.
References/Topics: 2021 IBC Section 601 and Table 601; Types I-A and IV-A fire-resistance ratings.


質問 # 55
Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:

正解:B

解説:
Option A is the incorrect statement and therefore the required answer. Under 2021 IBC Table 601, an exterior bearing wall in Type IV-C construction requires a two-hour fire-resistance rating , not one hour.
The tall mass timber classifications progressively vary the degree of noncombustible protection and allowable exposure, but the structural fire-resistance requirements remain substantial. Type IV-A exterior bearing walls require three hours. Type IV-B exterior bearing walls require two hours. Type IV-C exterior bearing walls also require two hours. Thus, options B, C, and D correctly reproduce the Table 601 values.
The special inspector must also recognize that Table 601 is not necessarily the only rating criterion affecting an exterior wall. Exterior walls are additionally subject to the requirements associated with fire separation distance, particularly Table 705.5. Where another IBC provision requires a higher rating, that more restrictive condition controls.
For mass timber construction, compliance also depends on the prescribed protective system, member dimensions, connections, joints, intersections, and exterior-side protection. A wall cannot be accepted as compliant solely because the timber cross section appears substantial; it must conform to the approved rated design.
References/Topics: 2021 IBC Section 601; Table 601; Section 602.4; Table 705.5.


質問 # 56
The building owner shall be responsible for each of the following for fire safety during construction except:

正解:A

解説:
Option C is not an IFC requirement. The 2021 IFC requires inspection records to be maintained on-site, but it does not require those records to be secured in a fire- and water-resistant safe.
Section 3303.2 requires the owner to designate a site safety director. Section 3303.3 then makes that director responsible for completing a daily fire safety inspection of the project site. Every day, building and outdoor construction areas must be evaluated against the prescribed fire-safety inspection items.
The results of each inspection must be documented and retained on-site until a certificate of occupancy has been issued . The records must also be immediately available at the site for presentation to the fire code official upon request. Options A, B, and D therefore accurately reflect the code requirements.
The daily inspection program covers practical hazards such as hot work, temporary heating, combustible debris, temporary electrical wiring, hazardous-material storage, fire apparatus access, hydrants, fire department connections, standpipe availability, and portable extinguishers.
For tall mass timber projects, this documentation is particularly important because substantial combustible construction may be present before permanent fire protection systems are complete.
References/Topics: 2021 IFC Sections 3303.2 and 3303.3; site safety director; daily fire-safety inspection and documentation.


質問 # 57
Fire-resistance ratings of members and assemblies can be established by all of the following except:

正解:D

解説:
ASTM E84 cannot be used to establish the hourly fire-resistance rating of a structural member or assembly.
Therefore, option B is correct.
ASTM E84 evaluates surface-burning characteristics , principally flame-spread and smoke-developed indices. Those measurements characterize how a material ' s exposed surface behaves when subjected to the standard tunnel test. They do not demonstrate that a wall, floor, roof, beam, column, or structural assembly will maintain integrity and structural performance for one, two, or three hours.
Fire-resistance ratings are instead established through the methods recognized by the IBC, including standard fire testing-principally ASTM E119 or UL 263-prescriptive rated construction provided by Section 721, and calculated fire-resistance procedures under Section 722. The code also recognizes appropriately documented approved designs and other approved methods within the Section 703 framework.
This distinction is particularly important in mass timber work because ASTM E84 may appear elsewhere in the code for flame-spread limitations on materials, but an acceptable E84 result does not establish structural fire endurance.
The special inspector must determine which approved fire-resistance methodology applies and verify that the installed assembly precisely reflects that design.
References/Topics: 2021 IBC Sections 703, 721 and 722; ASTM E119; UL 263; distinction between fire resistance and ASTM E84 surface-burning testing.


質問 # 58
Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?

正解:D

解説:
Option A correctly reflects the required noncombustible protection for protected Type IV-A mass timber.
Under IBC Section 602.4.1.2.1, the noncombustible protection applied to interior faces of Type IV-A mass timber must contribute the protection time determined by the applicable provisions of Section 722.7, but not less than 80 minutes .
The broader Type IV provisions are particularly important for interior exit and elevator hoistway enclosures.
In qualifying tall mass timber buildings with an occupied floor more than 75 feet above the lowest level of fire department access, mass timber interior exit and elevator hoistway enclosures are permitted up to the specified height limits only where protected in accordance with Section 602.4.1.2. For a two-hour, 120- minute-rated enclosure, at least 80 minutes must therefore come from the prescribed noncombustible protection.
Type IV-B likewise uses an 80-minute minimum for protected interior mass timber, so option B ' s 40-minute value is incorrect. Type IV-C has different exposure allowances and shaft-protection provisions, but option C does not state the controlling tall-building enclosure requirement tested here. Type IV-HT is not governed by the Type IV-A tall mass timber enclosure protection rule.
References/Topics: 2021 IBC Sections 602.4 and 602.4.1.2 through 602.4.1.2.1; Section 722.7.


質問 # 59
......

関連する認定を取得し、自分自身を向上させるために93-Tall-Mass-Timber-Buildings試験の準備をしようとするなら、あなたは非常に幸運に違いありません。すべての関係者の共同の努力により、当社は非常に便利で有用な93-Tall-Mass-Timber-Buildings学習教材を設計しました。さらに重要なことは、当社の学習教材が多くの人々が目標を達成し、関連する認証を取得するのに役立っていることを実践が証明していることです。当社の93-Tall-Mass-Timber-Buildings学習教材は、93-Tall-Mass-Timber-Buildings試験に合格し、関連する認定を取得することを切望している人々に最適な学習ツールです。