DOWNLOAD the newest itPass4sure LEED-AP-BD-C PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1FlYLKJjcBi5Pcm1xuRr58jHl8xyvd68J
Our LEED-AP-BD-C learning quiz is the accumulation of professional knowledge worthy practicing and remembering, so you will not regret choosing our LEED-AP-BD-C study guide. The best way to gain success is not cramming, but to master the discipline and regular exam points of question behind the tens of millions of questions. Our LEED-AP-BD-C Preparation materials can remove all your doubts about the exam. If you believe in our products this time, you will enjoy the happiness of success all your life
| Section | Objectives |
|---|---|
| Innovation | - Innovative strategies and exemplary performance
|
| Indoor Environmental Quality | - Occupant health and comfort
|
| Location and Transportation | - Site selection and access
|
| Regional Priority | - Geographically specific environmental priorities
|
| Integrative Strategies | - Integrative design process and early project analysis
|
| Sustainable Sites | - Site impact mitigation
|
| Water Efficiency | - Indoor and outdoor water use reduction
|
| Energy and Atmosphere | - Energy performance optimization
|
| Materials and Resources | - Sustainable material selection and waste reduction
|
>> New LEED-AP-BD-C Dumps Free <<
The itPass4sure is committed from the first day to help students ace the USGBC LEED-AP-BD-C exam at any cost. These formats are USGBC LEED-AP-BD-C PDF questions file, desktop practice test software, and web-based practice test software. All these three itPass4sure LEED-AP-BD-C Exam Questions formats are designed to help applicants ace the USGBC LEED-AP-BD-C exam preparation and enable the candidates to crack the final USGBC LEED-AP-BD-C exam easily.
NEW QUESTION # 144
A design team is working on a hospital project. In order to meet the Energy and Atmosphere Prerequisite, Minimum Energy Performance, what option is used?
Answer: D
Explanation:
The Whole Building Simulation option is used to meet the Energy and Atmosphere Prerequisite, Minimum Energy Performance for a hospital project. This option involves creating a detailed computer model of the building to simulate its energy performance and identify opportunities for improvement.
NEW QUESTION # 145
An HVAC system consists of an air handler supplying conditioned air (mixture of return air and outdoor air) to an office, corridor, conference room and lobby. For Indoor Environmental Quality Prerequisite, Minimum Indoor Air Quality Performance, the ventilation rate procedure calculations must be based upon what HVAC system configuration?
Answer: C
Explanation:
A multiple-zone system is a system that has one or more air handlers supplying conditioned air to more than one zone. A zone is a space or group of spaces within a building with heating and cooling requirements that are sufficiently similar so that desired conditions (e.g., temperature) can be maintained throughout using a single controlling device. The ventilation rate procedure calculations must be based on the multiple-zone system configuration because the HVAC system in the question serves different zones with different ventilation requirements. References: LEED v4 Reference Guide for Building Design and Construction, p.
6881; ASHRAE Standard 62.1-2010, Section 6.2.52
NEW QUESTION # 146
A project has total waste of 20 tons (18.1 tonnes) that includes the following:
* 8 tons (7.3 tonnes) of recycled demolition steel and concrete
* 2 tons (1.8 tonnes) of trees cleared from the site
. 3 tons (2.7 tonnes) of commingled scrap with 40% diverted
. 6 tons (5.4 tonnes) of used furniture donated to a non-profit organization
* 1 ton (0.9 tonnes) of removed carpet and ceiling tiles sent back to the manufacturer What is the percentage of diverted waste for Materials and Resources Credit, Construction and Demolition Waste Management?
Answer: B
Explanation:
The percentage of diverted waste for Materials and Resources Credit, Construction and Demolition Waste Management is calculated by dividing the total weight of diverted materials by the total weight of waste generated1. Diverted materials are those that are reused, recycled, salvaged, or donated2. In this case, the total weight of diverted materials is:
8 tons (7.3 tonnes) of recycled demolition steel and concrete
6 tons (5.4 tonnes) of used furniture donated to a non-profit organization
1 ton (0.9 tonnes) of removed carpet and ceiling tiles sent back to the manufacturer
40% of 3 tons (2.7 tonnes) of commingled scrap, which is 1.2 tons (1.1 tonnes) The sum of these weights is 16.2 tons (14.7 tonnes). The total weight of waste generated is 20 tons (18.1 tonnes). Therefore, the percentage of diverted waste is:
(16.2 / 20) x 100 = 81%
However, the credit allows for a 10% adjustment for vegetative waste, which is not considered a building material3. Therefore, the percentage of diverted waste after adjustment is:
(81 - 10) = 71%
The closest answer option to this value is B. 75%.
:
Construction and Demolition Waste Management
Construction Waste Management
Construction and Demolition Waste Management - Canada Green Building Council
NEW QUESTION # 147
Which of the following is required to earn Energy and Atmosphere Credit, Renewable Energy Production if using aSolar Photovoltaic System?
Answer: D
Explanation:
Explanation
The Energy and Atmosphere Credit, Renewable Energy Production rewards projects that use renewable energy systems to offset building energy costs1. According to the LEED Reference Guide for Building Design and Construction2, the credit has two options: Option 1. On-Site Renewable Energy and Option 2. Off-Site Renewable Energy. Option 1 requires the project to use renewable energy systems that are located on the project site and that produce electricity or thermal energy for the project. The amount of renewable energy production is calculated based on the percentage of the annual energy cost that is offset by the renewable energy systems. Option 2 requires the project to use renewable energy systems that are located off the project site and that are owned by the project or have a long-term contract with the project. The amount of renewable energy production is calculated based on the percentage of the annual energy use that is offset by the renewable energy systems.
Therefore, among the given options, only Option D is relevant to the credit requirements, as it implies that the solar photovoltaic system is located on the project site and that the produced electricity is consumed by the project. The other options, such as carbon offsets, daylighting strategies, and passive solar strategies, are not directly related to the credit requirements, although they may have other benefits for the project.
References:
* Renewable Energy Production | U.S. Green Building Council
* LEED Reference Guide for Building Design and Construction v4
* Solar Photovoltaic Technology Basics | Department of Energy
* Photovoltaic system - Wikipedia
NEW QUESTION # 148
Under the Building Design and Construction rating systems, projects can opt for a review process that helps teamsdetermine if the project is on track to achieve LEED certification at its preferred level. This process is referred to as
Answer: C
Explanation:
Explanation
A split review is an optional review process that allows project teams to submit the design and construction portions of their projects separately. This can help teams determine if the project is on track to achieve LEED certification at its preferred level, and identify any issues or clarifications needed before the final review. A split review also reduces the documentation burden and review time for the construction review12.
References: = Submitting a project for review, The LEED Submittal Process and Appeals
NEW QUESTION # 149
......
The language which is easy to be understood and simple, LEED-AP-BD-C exam questions are suitable for any learners no matter he or she is a student or the person who have worked for many years with profound experiences. So it is convenient for the learners to master the LEED-AP-BD-C Guide Torrent and pass the exam in a short time. The amount of the examinee is large. For the office workers, they are both busy in their job and their family life; for the students, they possibly have to learn or do other things.
LEED-AP-BD-C Valid Exam Camp: https://www.itpass4sure.com/LEED-AP-BD-C-practice-exam.html
BONUS!!! Download part of itPass4sure LEED-AP-BD-C dumps for free: https://drive.google.com/open?id=1FlYLKJjcBi5Pcm1xuRr58jHl8xyvd68J