If you face any hitch while using the USGBC LEED-AP-O-M practice exam software of PDFVCE, contact our customer support. Our team is available for the assistance of USGBC LEED-AP-O-M updated exam dumps users. Many candidates of the LEED-AP-O-M examination pay extra money because USGBC weaks the content of the test.
NEW QUESTION # 92
A property manager is evaluating various bids from pest management services. Which of the following service certifications would assist the existing building in achieving Indoor Environmental Quality Credit, Integrated Pest Management?
Answer: D
Explanation:
The correct answer is A because GreenPro, Ecowise, and Greenshield are service certifications that indicate the pest management services follow the principles of Integrated Pest Management (IPM), as stated in the web search results123.IPM is a comprehensive approach to pest management that minimizes the use of pesticides and maximizes the use of prevention, monitoring, and non-chemical methods4. The other options are incorrect because they either do not relate to pest management or do not follow the IPM principles.
References: =
* GreenPro Certified Service - National Pest Management Association, What is GreenPro? section
* EcoWise Certified - Pest Control Services, What is EcoWise Certified? section
* Green Shield Certified - About Us, What is Green Shield Certified? section
* LEED v4.1 O+M Reference Guide, page 239 =========================================
NEW QUESTION # 93
Which of the following options about project boundaries is correct?
Answer: D
Explanation:
The correct option regarding project boundaries in LEED is that the gross floor area (GFA) of the LEED project should be no less than 2% of the gross land area within the LEED project boundary. This requirement ensures that the project size is significant enough relative to the land area to make the application of LEED meaningful and impactful.References:LEED AP Operations + Maintenance Reference Guide, Project Site Factorssection.
NEW QUESTION # 94
Which of the following is a feature of the ENERGY STAR Portfolio Manager?
Answer: D
Explanation:
The ENERGY STAR Portfolio Manager is a tool that helps measure and track the energy and water use, waste and materials, and greenhouse gas emissions of buildings. One of its features is that it requires the calculation and input of site energy usage. This is essential for assessing the whole building energy performance and tracking changes in energy over time12.
References:
* ENERGY STAR Portfolio Manager
* An Overview of Portfolio Manager - ENERGY STAR
NEW QUESTION # 95
In order for a project team to meet the requirements of EQc8: Integrated Pest Management, how much advanced notice to building occupants is needed after the emergency application of a pesticide other than the least toxic pesticide?
Answer: D
Explanation:
The applicable emergency notification period is within 24 hours of the pesticide application. LEED ' s integrated pest-management framework gives priority to nonchemical preventive methods and least-risk pesticides. When a pesticide outside the least-risk category must be used, the communication protocol becomes particularly important because occupants may potentially be exposed.
The finalized LEED v5 O+M rating-system requirements require an IPM communication protocol and application-site signage. The signage must identify the pesticide, applicable registration information, and application date and remain in place for at least 24 hours before application and 24 hours after notification.
The v5 development guidance explicitly states that, for an emergency pesticide application, persons who requested notice are to be notified within 24 hours after the application, together with an explanation of the emergency.
The distinction is important: normal pesticide applications are planned sufficiently in advance to communicate before treatment, whereas an actual emergency may make prior notification impractical. The emergency provision therefore permits the application while still requiring prompt post-application communication.
The IPM plan must also document pesticide selection, application, occupant notification, action thresholds, monitoring, preventive measures, and the rationale for using a pesticide that is not least-risk.
Reference Topic: LEED v5 O+M - EQc8 Integrated Pest Management; Communication Protocol and Emergency Pesticide Notification.
NEW QUESTION # 96
Key functional and operational parameters such as occupied hours of a building, use by space type, required temperature settings, and lighting levels, are specified in the
Answer: C
Explanation:
The Owner Project Requirements (OPR) is a document that details the ideas, concepts, and criteria determined by the owner to be important to the success of the project. It typically includes key functional and operational parameters such as occupied hours of a building, use by space type, required temperature settings, and lighting levels. The OPR is used as a guiding document throughout the design and construction process to ensure that the team is aligned with the owner's vision and goals.
References: LEED v4: Building Operations + Maintenance Guide, Functional / Operational | WBDG - Whole Building Design Guide, Facilities Operations & Maintenance - An Overview - WBDG The Owner Project Requirements (OPR) is a critical document that outlines the functional and operational objectives of a project, reflecting the owner's needs and expectations. This document serves as a foundation for the design team to develop the Basis of Design (BOD) and guides the project through its lifecycle, ensuring that the owner's operational needs, such as occupied hours, use by space type, required temperature settings, and lighting levels, are met. The OPR typically includes information on building occupancy schedules, space usage types, environmental conditions like temperature and lighting requirements, and other owner-driven criteria essential for the building's design and operation. By clearly defining these parameters upfront, the OPR ensures that the project team has a clear understanding of what is expected from the building's performance, facilitating a design that aligns with the owner's vision and operational needs.
References:Based on the LEED AP documents and resources, such as the ASHRAE 90.1-2013 User Manual, which provides guidelines for determining design and operational parameters like lighting wattage for various space types (ASHRAE 90.1-2013, Section 9.1.4) .
NEW QUESTION # 97
......
To help our customer know our LEED-AP-O-M exam questions better, we have carried out many regulations which concern service most. You can ask what you want to know about our LEED-AP-O-M study guide. Once you submit your questions, we will soon give you detailed explanations. Even you come across troubles during practice the LEED-AP-O-M Learning Materials; we will also help you solve the problems. We are willing to deal with your problems. So just come to contact us.