問題 #43
Refer to the exhibit by clicking on the EXHIBIT button above.
In the detail shown, if the connections at the glulam beam and the steel plate required a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire one (1) hour of protection, the minimum required thickness for the wood block member providing protection for the bolt connections is _____ inches.
答案:D
解題說明:
The required minimum wood protection thickness is 1.75 inches , making option B correct. AWC Technical Report No. 10 establishes a thermal-separation methodology for protecting steel connectors and fasteners with sacrificial wood cover. Because the question specifies that the wood cover itself must provide the entire 60- minute fire-protection period, the protection thickness must be calculated using the thermal-separation provisions rather than relying on residual fire resistance from the connector or steel plate.
TR10 applies a reduction to the protection contribution of the base wood layer. Its connection examples use the relationship in Section 4.4.1.3, with the required thermal protection time divided by 0.85. For a 60-minute requirement, back-calculating the prescribed nonlinear wood charring equation gives approximately 1.71 inches of required wood thickness. The practical minimum corresponding to the available choices is therefore
1.75 inches.
The principle is critical for special inspection: steel connection components have high thermal conductivity and must remain below the temperature limits assumed by the connection fire design. The inspector must verify actual wood-cover thickness, fastening, continuity, and any gaps before concealment.
References/Topics: AWC Technical Report No. 10, Sections 4.4.1.3 and 4.5; connection thermal separation; wood protection of steel connectors. TR10 demonstrates the same calculation methodology for wood-covered steel connections.
問題 #44
Both surfaces of a two-hour-rated mass timber wall that serves as a required separation between a Group R and Group I-2 occupancy in a Type IV-C building must be protected by at least which of the following?
答案:D
解題說明:
The minimum additional protection is 1/2-inch gypsum board or an approved equivalent thermal barrier
, making option C correct.
The wall in the question functions as an occupancy separation. Under IBC Section 508.4.4.1, mass timber elements serving as fire barriers or horizontal assemblies separating occupancies in Type IV-B or IV-C construction must be separated from the building interior by an approved thermal barrier consisting of gypsum board at least 1/2 inch thick , or a material satisfying both applicable NFPA 275 thermal-barrier tests.
Because the wall separates two interior occupancies, each face is exposed to interior space; consequently, the thermal-barrier requirement applies to both surfaces .
This requirement must not be confused with the wall ' s two-hour fire-resistance rating. The underlying mass timber wall must independently satisfy the required two-hour assembly performance. The 1/2-inch gypsum protection is an additional thermal-barrier condition imposed because the rated separation is constructed of mass timber in Type IV-C.
Option D would provide substantially more gypsum protection than the specific occupancy-separation provision requires.
References/Topics: 2021 IBC Sections 508.4.4 and 508.4.4.1; Type IV-B/IV-C mass timber occupancy separations; approved thermal barriers; NFPA 275.
問題 #45
When Type X gypsum board is used as noncombustible protection over mass timber on the building ' s exterior walls, which of the following fasteners are permitted?
答案:A
解題說明:
Option A reproduces one of the two permitted exterior gypsum-board fastening methods in 2021 IBC Section
722.7.2.2. Type X gypsum board used as noncombustible protection on the exterior side of mass timber walls may be attached using galvanized nails of minimum 12 gage with a 7/16-inch head and sufficient length to penetrate the mass timber at least 1 inch .
The code also permits ASTM C1002 Type S, W, or G screws, but those screws must likewise penetrate the mass timber a minimum of 1 inch . Options C and D are therefore incorrect because they specify only 3/4- inch and 7/8-inch penetration, respectively. Option B is incorrect because it substitutes 16-gage nails for the minimum 12-gage requirement.
Section 722.7.2.2 additionally requires exterior Type X gypsum-board layers to be fastened 12 inches on center each way and 6 inches on center at joints or ends. Panel-edge fasteners must be located at least 1 inch and not more than 2 inches from the edge.
These fastening details are part of the conditions necessary to claim the protection contribution in Table
722.7.1(2).
References/Topics: 2021 IBC Sections 722.7.1 and 722.7.2.2; exterior Type X gypsum-board protection.
問題 #46
Periodic special inspection of sealants or adhesives as specified by the International Building Code Section
703.7 shall be conducted at which of the following locations?
答案:B
解題說明:
IBC Section 703.7 requires sealant or adhesive to resist air passage at the abutting edges and intersections of mass timber building elements where those elements are required to be fire-resistance rated. Section 1705.20 then requires periodic special inspection where those prescribed sealants or adhesives are installed. Option C repeats that first required location accurately.
Option D is defective because the code requires sealing at an intersection between mass timber and another material only where both intersecting building elements are required to be fire-resistance rated. The phrase
"one or the other" materially weakens the condition. Option A is also too broad. A code-defined joint is not automatically subject to Section 703.7; fire-resistant joint systems are separately regulated by Section 715 and, where applicable, Section 1705.18.
Option B describes the exception in reverse. Sealant or adhesive need not be added under Section 703.7 where it is not a required component of the tested fire-resistance-rated assembly. When it is part of the listed or tested assembly, it must be installed accordingly, but that statement does not identify the primary location requested.
References/Topics: 2021 IBC Sections 703.7 and 1705.20; sealing of adjacent rated mass timber elements; periodic inspection.
問題 #47
Proprietary nails can be used by referencing which ICC-ES Evaluation Report?
答案:A
解題說明:
ICC-ES ESR-1539 is the applicable evaluation report, making option C correct. ESR-1539 addresses nails and staples manufactured by participating companies and evaluates their use in engineered and nonengineered structural connections.
An ICC-ES Evaluation Report provides evidence that a proprietary product or system complies with specified building-code requirements where the product does not rely solely on the generic prescriptive provisions of the IBC. For proprietary nails, the report provides the technical basis needed to establish characteristics such as dimensions, materials, recognized structural applications, allowable design values, installation limitations, and conditions of use.
The current ICC-ES document is published as ESR-1539P, reflecting subsequent administrative updates to the report, but the identifying evaluation-report number remains 1539 , matching option C and the examination question.
For special inspection, merely recognizing the ESR number is not enough. The inspector should verify that the installed proprietary fastener is actually included in the report, that its diameter and length correspond to the approved construction documents, and that installation spacing, penetration, orientation, substrate, and other report conditions are satisfied.
References/Topics: ICC-ES ESR-1539, structural nails and staples; proprietary fastener evaluation and installation requirements. ICC-ES states that the nails and staples covered by ESR-1539 are used in engineered and prescriptive structural connections.
問題 #48
......
在這個競爭激烈的IT行業中,擁有一些認證證書是可以幫助你步步高升的。很多公司升職加薪的依據就是你擁有的認證證書的含金量。International Code Council 93-Tall-Mass-Timber-Buildings認證考試就是個含金量很高的考試。International Code Council 93-Tall-Mass-Timber-Buildings 認證證書能滿足很多正在IT行業拼搏的人的需求。PDFExamDumps可以為你提供International Code Council 93-Tall-Mass-Timber-Buildings認證考試的針對性訓練。你可以先在網上免費下載PDFExamDumps為你提供的關於International Code Council 93-Tall-Mass-Timber-Buildings 認證考試的培訓工具的試用版和部分練習題及答案作為嘗試。