| Section | Objectives |
|---|---|
| General & Construction Types | - Construction Classification — Type IV-A, IV-B, IV-C
|
| Structural & Connection Inspection | - Connection Design and Protection - Framing and Structural Elements |
| Mass Timber Materials | - CLT, Glulam, NLT, SCL and Engineered Wood Products |
| Fire-Resistance & Protection | - Fire-Resistance-Rated Assemblies - Concealed Spaces Protection - Noncombustible Protection & Encapsulation |
| Construction Fire Safety | |
| Inspection Duties & Documentation | - Inspection Reporting and Compliance Verification - Statement of Special Inspections |
>> 93-Tall-Mass-Timber-Buildings인증덤프공부자료 <<
Fast2test의 덤프선택으로International Code Council 93-Tall-Mass-Timber-Buildings인증시험에 응시한다는 것 즉 성공과 멀지 않았습니다. 여러분의 성공을 빕니다.
질문 # 48
Which of the following best describes the required protection for mass timber hoistway enclosure walls in Type IV-C construction?
정답:B
설명:
Type IV-C generally permits interior mass timber surfaces to remain exposed, but shaft and elevator hoistway enclosures are a specific exception to that broad exposure allowance. Section 602.4.3.6 requires shafts, elevator hoistways, and interior exit stairway enclosures constructed with mass timber to receive noncombustible protection having a minimum assigned protection time of 40 minutes . Option A is therefore correct.
Critically, protection is required on both the inside and outside of the shaft enclosure . The 40-minute value is an assigned contribution from the noncombustible protection; the complete enclosure must still satisfy whatever overall fire-resistance rating is required by Sections 713, 713.4, Table 601, or other applicable provisions.
Option B incorrectly applies the general Type IV-C exposed-interior allowance to a specifically regulated shaft condition. Option C is incomplete because 1/2-inch Type X gypsum board provides only 25 minutes under Table 722.7.1(2), not the required 40 minutes. A 5/8-inch Type X board provides a recognized 40- minute contribution when installed in accordance with Section 722.7.2. Option D does not state the prescribed Type IV-C shaft requirement.
References/Topics: 2021 IBC Sections 602.4.3.2 and 602.4.3.6; Tables 722.7.1(1) and 722.7.1(2).
질문 # 49
Materials acceptable for use in fire-protecting connections in Type IV-A construction includes each of the following except:
정답:D
설명:
Steel plates are not themselves a fire-protective material for the connection; therefore, option A is the exception. Steel plates frequently form part of mass timber structural connections, but because steel is highly thermally conductive, exposed steel can rapidly transmit heat into fasteners and adjacent wood. Consequently, the steel connection components are normally the items that require protection , not the material relied upon to provide that protection.
AWC guidance recognizes wood cover, fire-rated gypsum board, and other approved protection materials as valid means of shielding structural connections. TR10 specifically provides calculation procedures and worked examples using sacrificial wood cover and Type X gypsum wallboard. An approved protective coating can also be used where its documented fire-performance characteristics establish the required endurance under the approved design.
The distinction is important for inspection. A concealed steel plate does not automatically mean a protected connection. The special inspector must verify whether sufficient wood cover, gypsum protection, approved coating, or another engineered protection system surrounds the steel for the required duration. Hardware geometry, exposed edges, gaps, and penetrations can all materially affect thermal performance.
References/Topics: AWC Technical Report No. 10, protection of structural connections; 2021 IBC Section
2304.10.1; AWC guidance that connection protection can be provided by wood cover, gypsum board, or other approved material.
질문 # 50
In mass timber construction of Type IV-C, the fire-resistance ratings of bearing walls are permitted to be reduced by _____ where supporting a roof only.
정답:A
설명:
IBC Table 601, Footnote "a," permits a one-hour reduction in the required fire-resistance rating of the primary structural frame and bearing walls where those elements support a roof only. Option C is therefore correct.
For Type IV-C construction, the normal Table 601 requirement for bearing walls is two hours. Where a bearing wall qualifies as supporting only roof construction, application of the footnote permits that rating to be reduced from two hours to one hour.
The limitation "supporting a roof only" is critical. The reduction cannot be applied simply because a wall is located at the uppermost occupied level. If the wall carries a floor, mezzanine, transfer load, occupied rooftop structure, or another structural element beyond qualifying roof construction, the condition for the reduction is not satisfied.
Options A and B are not reductions prescribed by Table 601. Option D would effectively eliminate the entire normal two-hour Type IV-C bearing-wall rating, which the footnote does not permit.
For inspection purposes, the approved construction documents and structural load path must substantiate use of the reduction. The fire-protection installation should then be checked against the actual reduced rating specifically authorized by the design.
References/Topics: 2021 IBC Table 601, Footnote "a"; Type IV-C bearing walls supporting roof construction only.
질문 # 51
Refer to the exhibit by clicking on the EXHIBIT button above.
In the detail shown, the 2x2 block is intended for what purpose according to AWC Technical Report 10?
정답:D
설명:
The 2 × 2 block is intended to protect the abutting wood edges from the effects of char contraction. Therefore, option D is correct.
During fire exposure, wood chars and the char layer can shrink or contract. At an interface between two abutting timber components, that contraction can create a gap that allows heat and flames to penetrate deeper than predicted for a continuous exposed surface. AWC connection-fire-design methodology therefore requires additional protection at susceptible joints and interfaces. The block shields the abutting edges and maintains the sacrificial wood-cover path around the protected connection.
Its primary function is not decorative, nor is it simply an air-sealing component. Although limiting airflow can be a secondary consequence of closing the interface, the design purpose addressed by the technical guidance is control of premature fire penetration caused by char contraction. The block also should not be interpreted independently as a generic one-hour protective membrane for the steel ledger; the connection's total rating depends on the complete approved protection assembly.
The inspector should confirm the block's dimensions, species or product designation, fastening, continuity, and tight installation before the connection is concealed.
References/Topics: AWC Technical Report 10; AWC Fire Design Specification provisions addressing char contraction and gaps between abutting wood members.
질문 # 52
The time, in minutes, contributed to the fire resistance rating by the noncombustible protection of mass timber building elements, components, or assemblies, shall be established through a comparison of assemblies tested using procedures set forth in ASTM Standard:
정답:B
설명:
The applicable standard is ASTM E119 , making option B correct. IBC Section 703.6 establishes a performance method for determining the number of minutes contributed by noncombustible protection applied to mass timber.
The methodology requires two otherwise identical assemblies to be evaluated using the procedures of ASTM E119 or UL 263 . Test Assembly 1 is tested without the protective covering. Test Assembly 2 incorporates the representative noncombustible protection, including its actual configuration, attachment details, joint treatment, accessories, and other relevant installation conditions. The protection contribution is then calculated by subtracting the fire-resistance time of the unprotected assembly from that of the protected assembly.
ASTM E119 is specifically designed to evaluate fire endurance of building construction and structural assemblies under standardized fire exposure. ASTM D3498, by contrast, is an adhesive specification referenced by the IBC for sealing certain mass timber interfaces. The other standards listed are not the prescribed comparative fire-resistance test for this determination.
References/Topics: 2021 IBC Sections 703.6 and 722.7.1; ASTM E119; UL 263; determination of noncombustible protection time contribution.