Fast2testの International Code Councilの93-Tall-Mass-Timber-Buildings試験トレーニング資料を手に入れるなら、あなたは最も新しいInternational Code Councilの93-Tall-Mass-Timber-Buildings学習教材を手に入れられます。Fast2testの 学習教材の高い正確性は君がInternational Code Councilの93-Tall-Mass-Timber-Buildings認定試験に合格するのを保証します。もしうちの学習教材を購入した後、商品は問題があれば、或いは試験に不合格になる場合は、私たちが全額返金することを保証いたします。
| Section | Objectives |
|---|---|
| Topic 1: Inspection Duties & Documentation | - Inspection Reporting and Compliance Verification - Statement of Special Inspections |
| Topic 2: Fire-Resistance & Protection | - Fire-Resistance-Rated Assemblies - Concealed Spaces Protection - Noncombustible Protection & Encapsulation |
| Topic 3: Mass Timber Materials | - CLT, Glulam, NLT, SCL and Engineered Wood Products |
| Topic 4: Structural & Connection Inspection | - Framing and Structural Elements - Connection Design and Protection |
| Topic 5: General & Construction Types | - Construction Classification — Type IV-A, IV-B, IV-C
|
| Topic 6: Construction Fire Safety |
>> 93-Tall-Mass-Timber-Buildings試験準備 <<
今日、知識は精神労働よりも多くの富を生み出すことができるため、知識能力と精神労働は肉体労働よりも価値があります。ある分野で専門知識の能力を高めれば、多くの価値を生み出し、高収入で良い仕事を得ることができます。 93-Tall-Mass-Timber-Buildings認定試験に合格すると、その達成に役立ちます。93-Tall-Mass-Timber-Buildingsトレーニング資料は、93-Tall-Mass-Timber-Buildingsテストの準備に最適な学習資料です。 93-Tall-Mass-Timber-Buildingsガイド資料では、重要な情報を組み合わせて、クライアントが基盤を固め、時代とともに前進するのを支援します。
質問 # 69
Both surfaces of a two-hour-rated mass timber wall that serves as a required separation between a Group R and Group I-2 occupancy in a Type IV-C building must be protected by at least which of the following?
正解:B
解説:
The minimum additional protection is 1/2-inch gypsum board or an approved equivalent thermal barrier
, making option C correct.
The wall in the question functions as an occupancy separation. Under IBC Section 508.4.4.1, mass timber elements serving as fire barriers or horizontal assemblies separating occupancies in Type IV-B or IV-C construction must be separated from the building interior by an approved thermal barrier consisting of gypsum board at least 1/2 inch thick , or a material satisfying both applicable NFPA 275 thermal-barrier tests.
Because the wall separates two interior occupancies, each face is exposed to interior space; consequently, the thermal-barrier requirement applies to both surfaces .
This requirement must not be confused with the wall ' s two-hour fire-resistance rating. The underlying mass timber wall must independently satisfy the required two-hour assembly performance. The 1/2-inch gypsum protection is an additional thermal-barrier condition imposed because the rated separation is constructed of mass timber in Type IV-C.
Option D would provide substantially more gypsum protection than the specific occupancy-separation provision requires.
References/Topics: 2021 IBC Sections 508.4.4 and 508.4.4.1; Type IV-B/IV-C mass timber occupancy separations; approved thermal barriers; NFPA 275.
質問 # 70
In mass timber construction of Type IV-C, the fire-resistance ratings of bearing walls are permitted to be reduced by _____ where supporting a roof only.
正解:A
解説:
IBC Table 601, Footnote "a," permits a one-hour reduction in the required fire-resistance rating of the primary structural frame and bearing walls where those elements support a roof only. Option C is therefore correct.
For Type IV-C construction, the normal Table 601 requirement for bearing walls is two hours. Where a bearing wall qualifies as supporting only roof construction, application of the footnote permits that rating to be reduced from two hours to one hour.
The limitation "supporting a roof only" is critical. The reduction cannot be applied simply because a wall is located at the uppermost occupied level. If the wall carries a floor, mezzanine, transfer load, occupied rooftop structure, or another structural element beyond qualifying roof construction, the condition for the reduction is not satisfied.
Options A and B are not reductions prescribed by Table 601. Option D would effectively eliminate the entire normal two-hour Type IV-C bearing-wall rating, which the footnote does not permit.
For inspection purposes, the approved construction documents and structural load path must substantiate use of the reduction. The fire-protection installation should then be checked against the actual reduced rating specifically authorized by the design.
References/Topics: 2021 IBC Table 601, Footnote "a"; Type IV-C bearing walls supporting roof construction only.
質問 # 71
The fire-resistance of a protected mass timber assembly is equivalent to the fire resistance time of the:
正解:A
解説:
The fire resistance of a protected mass timber element is determined by adding the inherent fire resistance of the mass timber to the protection time contributed by the approved noncombustible protection. Therefore, option D is correct.
The mass timber component provides structural endurance through its large cross section and predictable charring behavior. The noncombustible protection delays heating, ignition, and charring of the protected timber surfaces. Its contribution may be established by testing or by assigned values permitted under IBC Section 722.7. The combined value must equal or exceed the rating required for the building element.
Option A ignores the additional protection contribution. Option B ignores the structural endurance provided by the timber after the protective membrane has performed its assigned function. Option C incorrectly substitutes "finish rating time." A finish rating measures temperature rise behind a protective membrane and is not automatically the same as the added fire-resistance contribution established for protected mass timber.
Inspection must confirm that the protection system matches the approved calculation or tested configuration, including material type, thickness, layer count, fastening, edge treatment, joints, penetrations, and continuity.
References/Topics: 2021 IBC Sections 703.6, 703.8 and 722.7; protected mass timber performance method and noncombustible protection contribution.
質問 # 72
The maximum allowable height for a Group I-4 building of Type IV-B construction provided with an automatic sprinkler system in accordance with Section 903.3.1.1 is _____ ft.
正解:B
解説:
The applicable requirement is found in 2021 IBC Section 504.3 and Table 504.3. The table regulates building height in feet above grade plane by occupancy, construction type, and sprinkler condition. For a Group I-4 occupancy equipped throughout with a Section 903.3.1.1 sprinkler system, the applicable row is the sprinklered "S" row.
Reading across that row to Type IV-B construction gives a maximum building height of 120 feet. Therefore, option B is correct. The 180-foot value applies to Type IV-A construction for the same occupancy and sprinkler condition. The 85-foot value, which is not offered, applies to Type IV-C and Type IV-HT. The 270- foot value generally appears for certain lower-hazard occupancies-such as Groups A, B, E, F, M, S and U- when constructed as sprinklered Type IV-A, but it is not permitted for Group I-4.
This distinction reflects the additional life-safety considerations associated with custodial-care occupancies. A special inspector should verify that the approved construction documents identify both the correct occupancy classification and construction type because either classification directly changes the permitted height.
References/Topics: 2021 IBC Section 504.3; Table 504.3, Group I-4, sprinklered Type IV-B construction; Section 903.3.1.1.
質問 # 73
Refer to the exhibit by clicking on the EXHIBIT button above.
In the detail shown, if the connections at the glulam beam and the steel plate required a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire one (1) hour of protection, the minimum required thickness for the wood block member providing protection for the bolt connections is _____ inches.
正解:A
解説:
The required minimum wood protection thickness is 1.75 inches , making option B correct. AWC Technical Report No. 10 establishes a thermal-separation methodology for protecting steel connectors and fasteners with sacrificial wood cover. Because the question specifies that the wood cover itself must provide the entire 60- minute fire-protection period, the protection thickness must be calculated using the thermal-separation provisions rather than relying on residual fire resistance from the connector or steel plate.
TR10 applies a reduction to the protection contribution of the base wood layer. Its connection examples use the relationship in Section 4.4.1.3, with the required thermal protection time divided by 0.85. For a 60-minute requirement, back-calculating the prescribed nonlinear wood charring equation gives approximately 1.71 inches of required wood thickness. The practical minimum corresponding to the available choices is therefore
1.75 inches.
The principle is critical for special inspection: steel connection components have high thermal conductivity and must remain below the temperature limits assumed by the connection fire design. The inspector must verify actual wood-cover thickness, fastening, continuity, and any gaps before concealment.
References/Topics: AWC Technical Report No. 10, Sections 4.4.1.3 and 4.5; connection thermal separation; wood protection of steel connectors. TR10 demonstrates the same calculation methodology for wood-covered steel connections.
質問 # 74
......
93-Tall-Mass-Timber-Buildingsガイドトレントの3つの異なるバージョンの中で最も普及しているのはPDFバージョンであり、International Code Councilは特に適切であり、若者に歓迎されていることは間違いありません。このバージョンにはいくつかの機能があります。まず、93-Tall-Mass-Timber-Buildings準備ガイドのPDFバージョンを紙に印刷できます。ただし、メモを作成して重要な試験ポイントを強調することができます。前述のように、93-Tall-Mass-Timber-Buildings試験トレントサポート無料のデモダウンロードに加えて、93-Tall-Mass-Timber-Buildings準備ガイドを十分に理解し、適切で満足できる場合は購入することが理想的です。