BTW, DOWNLOAD part of Actualtests4sure FlashArray-Storage-Professional dumps from Cloud Storage: https://drive.google.com/open?id=1b8UAd-T9QnEID73MMY-uxoAsqzweFS6u
When we get into the job, our FlashArray-Storage-Professional training materials may bring you a bright career prospect. Companies need employees who can create more value for the company, but your ability to work directly proves your value. Our FlashArray-Storage-Professional certification guide can help you improve your ability to work in the shortest amount of time, for more promotion opportunities and space for development. Believe it or not that up to you, our FlashArray-Storage-Professional Training Materials are powerful and useful, it can solve all your stress and difficulties in reviewing the FlashArray-Storage-Professional exams.
| Certification Vendor: | Pure Storage |
|---|---|
| Exam Name: | Pure Certified FlashArray Storage Professional |
| Exam Number: | FASP |
| Available Languages: | English |
| Real Exam Qty: | 80 |
| Exam Price: | $300 USD |
| Related Certifications: | Pure Storage FlashArray Support Specialist Pure Storage FlashArray Architect Professional Pure Storage FlashArray Implementation Specialist |
| Exam Format: | Multiple Choice |
| Certificate Validity Period: | 3 years |
| Exam Duration: | 120 minutes |
| Sample Questions: | Pure Storage FlashArray-Storage-Professional Sample Questions |
| Exam Way: | Online, proctored |
| Pre Condition: | Recommended for new and experienced IT professionals. |
| Official Syllabus URL: | https://academy.purestorage.com/student/page/2164505-certification-fasp |
>> FlashArray-Storage-Professional Positive Feedback <<
The FlashArray-Storage-Professional exam real questions are the ideal and recommended study material for quick and complete Pure Storage FlashArray-Storage-Professional exam preparation. As a FlashArray-Storage-Professional Exam candidate you should not ignore the FlashArray-Storage-Professional exam questions and must add the Pure Storage FlashArray-Storage-Professional exam questions in preparation.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
NEW QUESTION # 27
What is the proper procedure for stopping asynchronous replication and in-progress transfers?
Answer: B
Explanation:
According to the official Pure Storage FlashArray Asynchronous Replication Configuration and Best Practices Guide, the proper and immediate method to halt an active, in-progress asynchronous replication transfer is by disallowing the protection group at the target.
When you navigate to the target FlashArray and disallow the specific Protection Group, Purity immediately breaks the replication authorization for that group. If there is an in-progress snapshot transfer occurring at that exact moment, the transfer is immediately stopped, and the partially transferred snapshot data is discarded on the target side.
Here is why the other options are incorrect:
Disabling the replication schedule (B): Toggling the replication schedule to "Disabled" only prevents future scheduled snapshots from being created and sent. It does not kill or interrupt a replication transfer that is already currently in progress.
Removing the volume member from a protection group (A): Modifying the members of a protection group updates the configuration for the next snapshot cycle. It does not actively abort the transmission of the current point-in-time snapshot that the array is already busy sending over the WAN.
NEW QUESTION # 28
An administrator is running commands to verify NVME/TCP connectivity from the hosts to the FlashArray. They use the command ping -M do -s 8972 <ip_addr> from the initiator and it fails.
What should the administrator do to resolve the issue?
Answer: B
Explanation:
When configuring NVMe/TCP (or iSCSI) for optimal performance on a Pure Storage FlashArray, configuring Jumbo Frames (an MTU of 9000) end-to-end is a standard best practice.
The command ping -M do -s 8972 <ip_addr> is specifically used to verify Jumbo Frame configuration across the network.
The -M do flag sets the "Do Not Fragment" (DF) bit, meaning the network is not allowed to break the packet into smaller pieces.
The -s 8972 flag sets the ICMP data payload to 8972 bytes. When you add the standard 8-byte ICMP header and the 20-byte IP header, the total packet size equals exactly 9000 bytes.
If this ping command fails, it indicates that somewhere along the network path between the host (initiator) and the FlashArray (target), a switch port, router, or network interface is not configured to support an MTU of 9000. The packet is being dropped because it is too large and cannot be fragmented. The administrator must verify the MTU settings on every network hop (switches, routers, and host NICs) to resolve the issue.
Here is why the other options are incorrect:
Engage support to enable NVME/ TCP services (A): The failure of a Jumbo Frame ping test is a Layer 2/Layer 3 network configuration issue, not an indicator that the NVMe/TCP storage protocol service is disabled on the array.
Run the command from the target (C): While pinging from the FlashArray back to the host is a valid secondary troubleshooting step, it will likely also fail if the network path doesn't support Jumbo Frames. The actual resolution is to fix the MTU on the network hops.
NEW QUESTION # 29
How would a FlashArray administrator view external latency for write requests for a specific volume?
Answer: C
Explanation:
In the Pure Storage FlashArray GUI, granular performance metrics (Latency, IOPS, Bandwidth) are located under the Analysis > Performance tabs. When you navigate to the Volumes sub-tab and select a specific volume, Purity displays a unified line graph tracking the performance of that volume over time.
By default, the Latency graph simultaneously plots Read, Write, and Mirrored Write (for volumes participating in an ActiveCluster or synchronous replication pod) latencies. Because these lines can overlap or compress the Y-axis (especially if one metric spikes), isolating a specific metric requires interacting with the graph's legend.
To view the exact, un-obscured latency for standard write requests to that volume, the administrator should click on "Read" and "Mirrored Write" in the chart's legend. This deselects those metrics, effectively hiding their lines from the graph and automatically rescaling the view to exclusively display the host write latency.
Here is why the other options are incorrect:
Health > Network (A): The Health tab is used to check the hardware status of the physical controller ports, including link state and errors. While you might see port-level throughput or queue depth here, it does not provide volume-specific application latency.
Storage > Volumes > Details (B): The Storage tab is primarily used for provisioning and configuration management. Clicking on a volume here will show its size, data reduction ratio, snapshot policies, and connected hosts, but it does not provide detailed interactive performance graphs.
NEW QUESTION # 30
A customer is managing a VMware environment and has recently copied a snapshot from a Pure Storage array to a new volume. When attempting to mount this volume on a VMware virtual machine, the operation fails.
How should this be resolved?
Answer: A
Explanation:
VMFS UUID Conflict: When you create a volume from a snapshot on a FlashArray, the data is a block-for-block copy of the original. This includes the VMFS metadata and the unique identifier (UUID) of the datastore.
ESXi Protection Mechanism: When an ESXi host sees a volume that contains a VMFS signature identical to one already mounted (or one it has seen before but on a different device ID), it flags the volume as a "snapshot." To prevent data corruption or VM identity conflicts, VMware will not automatically mount this "duplicate" volume.
The Resignaturing Process: By choosing to Resignature the volume (via the "Mount Datastore" wizard in vCenter or the ESXi CLI), VMware assigns a new, unique UUID to the VMFS volume. This allows the host to treat it as a distinct, independent datastore.
Why Option B is incorrect: Reformatting the volume would indeed allow it to be mounted, but it would destroy all the data you just copied from the snapshot, defeating the purpose of the operation.
Why Option C is incorrect: While there are advanced settings in VMware (like LVM.enableResignature), they don't solve the issue of the operation "failing" during a standard mount attempt; they simply change how the host behaves. Resignaturing is the standard, safe, and recommended workflow for mounting snapshot copies in a VMware environment.
NEW QUESTION # 31
A storage administrator has presented VMFS datastores from a FlashArray with 10TB of raw capacity.
Why would the administrator see system space when logging in to the FlashArray GUI?
Answer: B
Explanation:
On a Pure Storage FlashArray, "System Space" is a specific GUI-reported metric. Purity has a predefined, hidden internal space budget-typically around 20% of the raw mapped capacity (which would be 2TB on a 10TB array)-reserved for internal array operations. This budget covers RAID/parity overhead, metadata, and reclaimable space (data from deleted volumes, snapshots, or overwritten blocks that are waiting for the backend garbage collection process to fully erase them from the flash chips).
Normally, this internal overhead stays below the 20% budget, and "System Space" displays as 0.00 in the GUI. However, if an administrator deletes a massive amount of data at once, causing the reclaimable space to exceed that 2TB budget, the overflow is prominently displayed in the GUI as "System Space." Here is why the other options are incorrect:
Virtual machines have not yet issued an unmap command (A): If a VMware VM deletes a file but the OS hasn't issued an UNMAP/TRIM command, the FlashArray is completely unaware that the data was deleted. Therefore, the array continues to report that capacity as standard Volume Space, not System Space.
More than 2TB of volume snapshots were destroyed (C): While destroying snapshots leads to reclaimable space, "reclaimable space" (Option B) is the specific, correct Purity architectural term and metric that the system uses to calculate the internal budget threshold.
NEW QUESTION # 32
......
FlashArray-Storage-Professional Real Dump: https://www.actualtests4sure.com/FlashArray-Storage-Professional-test-questions.html
DOWNLOAD the newest Actualtests4sure FlashArray-Storage-Professional PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1b8UAd-T9QnEID73MMY-uxoAsqzweFS6u