Through years of persistent efforts and centering on the innovation and the clients-based concept, our company has grown into the flagship among the industry. Our company struggles hard to improve the quality of our H20-923_V1.0 study materials and invests a lot of efforts and money into the research and innovation of our H20-923_V1.0 Study Materials. Our brand fame in the industry is like the Microsoft in the computer industry, Google in the internet industry and Apple in the cellphone industry. High quality, considerate service, constant innovation and the concept of customer first are the four pillars of our company.
| Certification Vendor: | Huawei |
|---|---|
| Exam Name: | HCSP-Field-Data Center Facility V1.0 |
| Exam Number: | H20-923_V1.0 |
| Exam Format: | True/False questions, Single-answer questions, Multiple-answer questions |
| Certificate Validity Period: | 3 years |
| Related Certifications: | HCSP-Field-Data Center Facility (Modular DC) V1.0 HCSP-Field-Data Center Facility (Power) V1.0 |
| Passing Score: | 600 out of 1000 |
| Exam Duration: | 90 minutes |
| Available Languages: | English |
| Exam Price: | 100 USD |
| Real Exam Qty: | 60 |
| Recommended Training: | Huawei Official Training |
| Exam Registration: | Pearson VUE Registration |
| Sample Questions: | Huawei H20-923_V1.0 Sample Questions |
| Exam Way: | Online proctored or onsite at Pearson VUE test centers |
| Pre Condition: | Basic knowledge of data center infrastructure, power and cooling systems; recommended to have HCIA-Data Center Facility certification or equivalent experience |
| Official Syllabus URL: | https://e.huawei.com/en/talent/cert/#/specialistCert |
>> H20-923_V1.0 Real Questions <<
In today's Huawei world getting the HCSP-Field-Data Center Facility V1.0 (H20-923_V1.0) certification exam is very crucial. With the growing popularity of credentials, the demand for H20-923_V1.0 certification exam holders has increased. Success in the H20-923_V1.0 Exam has become the need of time. People who fail the Huawei H20-923_V1.0 certification exam face loss of time and money.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
| Topic 7 |
|
| Topic 8 |
|
| Topic 9 |
|
| Topic 10 |
|
| Topic 11 |
|
NEW QUESTION # 96
When a critical alarm is generated for the unit, the indicator on the LCD controller turns red and the buzzer beeps continuously.
Answer: B
Explanation:
In Huawei data center facility equipment (such as precision cooling units and related controllers), alarm presentation follows a clear severity-based design so technicians can recognize urgency immediately without entering detailed menus. Acritical alarmrepresents the highest severity level and is treated as a condition that may impact safe operation, cooling continuity, or equipment protection. For this reason, the LCD controller uses the most prominent visual and audible indications: theindicator turns redto show critical severity, and thebuzzer sounds continuouslyto ensure the alarm cannot be overlooked in a noisy equipment-room environment. This behavior supports rapid response: O&M personnel can quickly identify that immediate action is required, then open the alarm list to locate the root cause, confirm whether the unit has derated or stopped, and execute the prescribed troubleshooting steps (for example, checking power status, sensor readings, fan/compressor status, water flow/pressure, and protection interlocks). Therefore, the statement correctly describes the standard critical-alarm indication method on the LCD controller.
NEW QUESTION # 97
Which of the following is the cabling mode of external power cables in IT scenarios of the FusionDC1000A?
Answer: B
Explanation:
In the FusionDC1000A IT scenario, the external input power cables are designed to enter the power distribution system through dedicated cable inlets at the bottom of the Power PDB. During installation, the procedure requires opening the Power PDB, removing the plugs from the bottom cable holes, and routing the external input power cables into the cabinet through these bottom entries before arranging them along the nearby cable support/bridge inside the Power PDB area.
After the cables are terminated (for example, L1/L2/L3/N and PE), the bottom cable entries are resealed using waterproof sealing materials to maintain enclosure protection performance. This bottom-entry method supports reliable mechanical routing for thick/armored power cables, reduces bending stress, helps maintain orderly segregation from signal cabling, and improves on- site safety by guiding high-current cables through a controlled inlet path. Therefore, the correct cabling mode for external power cables in FusionDC1000A IT scenarios is bottom cabling.
NEW QUESTION # 98
If the startup password authentication for a smart module is not complete, the ECC800-Pro WebUI and app cannot be used for commissioning.
Answer: B
Explanation:
In Huawei smart module commissioning and O&M workflows,startup password authentication is a mandatory security initialization stepfor the controller and its management channels. The ECC800-Pro provides WebUI and mobile app access for tasks such as device discovery, parameter setting, site configuration, alarm verification, and functional commissioning. Before these commissioning functions are allowed, the system requires completion of startup authentication actions, typically includinginitial password setup or password change, confirmation of authentication policies, and activation of secure access control. This prevents unauthorized users from entering the management plane during the critical initial stage when default credentials or incomplete security settings could exist. If startup password authentication is not completed, the platform restricts access to commissioning pages and app-based commissioning features, ensuring that configuration changes, device binding, and control operations cannot be executed until the controller is placed into a compliant, secured state. This design aligns with data center facility management best practices where commissioning must begin only after management access is hardened and auditable.
NEW QUESTION # 99
The NetEco supports manual backup and automatic backup.
Answer: B
Explanation:
NetEco is a management platform that stores critical operational data, including site configuration, device models, user/role information, historical alarms, trend data, reports, and northbound integration settings. To protect these assets and ensure service continuity, NetEco provides a built-in backup mechanism that supports both manual and automatic backup modes.
Manual backup is typically used before major operations such as version upgrades, configuration changes, northbound interface adjustments, or large-scale device onboarding, so engineers can create a restore point on demand. Automatic backup is used for routine risk control and is normally implemented through scheduled tasks, allowing backups to be generated at defined intervals to reduce data-loss exposure in case of hardware failure, system corruption, or accidental misconfiguration. In standard O&M practice, automatic backups are combined with retention policies (for example, keeping a rolling set of backup files), storage capacity checks, and periodic restore verification to confirm backup integrity. This dual-mode backup capability is a foundational requirement for stable long-term operation of management systems like NetEco.
NEW QUESTION # 100
Which of the following statements is false about how to start an electric heater?
Answer: B
Explanation:
Huawei precision cooling logic separates heater enablement into distinct control strategies to avoid unnecessary heating and to keep humidity control stable. InLow temperature heating, the heater is governed purely by the room temperature control demand: if temperature is below the heating threshold (or below setpoint with heating conditions met), the heater can start regardless of whether dehumidification is enabled, which matches statement D. InDehumidification heating, the heater is not a general low-temperature heater; it is an auxiliary function used to prevent overcooling during dehumidification and to maintain temperature while the unit dehumidifies. Therefore, the heater in this mode is permitted to start only when thedehumidification function is activeand temperature conditions require compensation, which matches statement B. Statement C is false because it incorrectly claims thatanyof the three selections will start heating automatically whenever room temperature is low; that is not true for "Dehumidification heating" unless dehumidification is actually enabled and running.