BONUS!!! Download part of ExamPrepAway EDGE-Expert dumps for free: https://drive.google.com/open?id=1ZfhNR9mQmS__OKa6SdmNySX96BOHkHC-
We provide 24-hour online service for all customers who have purchased EDGE-Expert test guide. You can send us an email to ask questions at anytime, anywhere. For any questions you may have during the use of EDGE-Expert exam questions, our customer service staff will be patient to help you to solve them. At the same time, if you have problems with downloading and installing, Excellence in Design for Greater Efficiencies (EDGE Expert) Exam torrent prep also has dedicated staff that can provide you with remote online guidance. In order to allow you to use our products with confidence, EDGE-Expert Test Guide provide you with a 100% pass rate guarantee. Once you unfortunately fail the exam, we will give you a full refund, and our refund process is very simple.
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Energy Efficiency | 25% | - Energy baseline calculation
|
| Topic 2: EDGE Fundamentals & Framework | 20% | - Core principles of EDGE
|
| Topic 3: EDGE Software & Application | 10% | - Using EDGE calculation tool
|
| Topic 4: Certification Process & Roles | 10% | - Role of EDGE Expert
|
| Topic 5: Materials & Embodied Carbon | 15% | - Embodied energy baseline
|
| Topic 6: Water Efficiency | 20% | - Water baseline assessment
|
>> EDGE-Expert Study Center <<
One of the biggest highlights of the EDGE-Expert exam materials is the availability of three versions: PDF, app/online, and software/pc, each with its own advantages: The PDF version of EDGE-Expert exam materials has a free demo available for download. You can print exam materials out and read it just like you read a paper. The online version of EDGE-Expert Exam Materials is based on web browser usage design and can be used by any browser device. At the same time, the first time it is opened on the Internet, it can be used offline next time. You can practice anytime, anywhere.
NEW QUESTION # 69
How many years of experience in related fields are required for applicants without a construction-related higher qualification to become an EDGE Expert?
Answer: C
Explanation:
The eligibility criteria for becoming an EDGE Expert are designed to ensure candidates have sufficient background to advise on green building projects. The EDGE Expert and Auditor Protocols specify the requirements for candidates without a construction-related higher qualification: "Applicants without a higher education qualification in a construction-related field (e.g., architecture, engineering) must have a higher education qualification in any field plus at least three years of experience in the construction industry as a skilled professional or tradesperson to qualify for EDGE Expert training and certification" (EDGE Expert and Auditor Protocols, Section 3.1: Eligibility Criteria). Option C, at least 3 years, directly matches this requirement. Option A (at least 1 year) and Option B (at least 2 years) are insufficient, as they fall below the minimum threshold: "Less than three years of experience does not meet the eligibility criteria for candidates without a construction-related degree, as this duration ensures adequate practical knowledge of building design and construction processes" (EDGE Expert and Auditor Protocols, Section 3.1: Eligibility Criteria).
Option D (at least 5 years) exceeds the minimum requirement, which is not necessary: "While additional experience is beneficial, the minimum requirement for EDGE Expert eligibility is three years for non- construction degree holders" (EDGE User Guide, Section 6.4: Working with EDGE Experts). The EDGE Certification Protocol also notes: "The three-year experience requirement for non-construction graduates ensures that EDGE Experts have sufficient industry exposure to provide meaningful consultancy, balancing accessibility with competence" (EDGE Certification Protocol, Section 1.3: Program Structure). Additionally, the EDGE User Guide clarifies: "Candidates with a construction-related degree are exempt from the experience requirement, but those without such a degree must demonstrate at least three years of relevant experience to qualify for the EDGE Expert exam" (EDGE User Guide, Section 6.4: Working with EDGE Experts). Therefore, at least 3 years of experience (Option C) is required for applicantswithout a construction- related higher qualification.
Reference:EDGE Expert and Auditor Protocols, Section 3.1: Eligibility Criteria; EDGE Certification Protocol, Section 1.3: Program Structure; EDGE User Guide Version 2.1, Section 6.4: Working with EDGE Experts.
NEW QUESTION # 70
How many measures need to be selected in order to meet the EDGE Energy Standard?
Answer: A
Explanation:
In the EDGE system, compliance with the Energy Standard is not achieved by selecting a fixed number or a fixed percentage of measures. Instead, the project must demonstrate that the selected package of energy measures, when modeled in the EDGE software, achieves the minimum required energy savings compared to the local baseline. Because projects differ by climate, building type, geometry, and system choices, the number of measures needed can vary widely. One project might reach the target with a few high-impact measures, while another may need many smaller improvements.
At the same time, the curriculum explains that some measures are marked as required. These are mandatory prerequisites within the EDGE methodology and must be implemented where applicable. A project cannot claim compliance while omitting required measures. Therefore, while you may choose any combination of optional measures to reach the energy savings threshold, you must still implement all required measures as part of meeting EDGE requirements.
Options A, B, and C incorrectly imply a universal count-based rule. The only correct statement is that the project must implement at least all required measures, and then add any additional measures necessary to achieve the minimum energy savings target.
NEW QUESTION # 71
Client has provided the specification as per the image for low flow shower heads. What is the flow rate for shower heads that should have been entered to EDGE software?
Answer: D
Explanation:
According to the CBCI EDGE curriculum, when entering plumbing fixture data into the EDGE software, the value required is the actual flow rate of the fixture in liters per minute, not the product code, price, or any other specification number shown in supplier documentation.
From the specification image, the overhead shower is described as having a single flow rate of 6 liters per minute. Other numbers visible in the specification, such as 1,315 or 3,590, represent product codes or pricing information, not water flow rates. The 4 liters per minute value in the image applies to a wall mixer component and not to the shower head itself.
In EDGE, water savings for showers are calculated based on the flow rate combined with default usage assumptions. Therefore, the correct value to input for a low-flow shower head is its rated flow in liters per minute. Since the overhead shower shown has a flow rate of 6 liters per minute, that is the value that should be entered into the EDGE software.
Accurate entry of fixture flow rates is essential because it directly affects the calculated percentage reduction in water consumption compared to the baseline case.
NEW QUESTION # 72
In the EDGE software, the Base Case selection of external wall materials in hotels relies on information derived from:
Answer: A
Explanation:
The EDGE software uses a Base Case to establish a benchmark for resource consumption, tailored to local conditions. The EDGE Methodology Report explains how the Base Case is constructed: "The Base Case for external wall materials in hotels is determined using data from market surveys of typical building practices in the project's country, supplemented by national building performance codes where available. This ensures the baseline reflects local construction norms and regulatory standards" (EDGE Methodology Report Version 2.0, Section 3.1: Base Case Determination). Option A matches this description by referencing typical building practices and national codes. Option B incorrectly refers to global practices and international codes, which EDGE does not use, as the software prioritizes local context. Option C, focusing on corporate specifications, is not part of the Base Case methodology, as the Base Case is standardized, not project-specific. Option D, involving local suppliers or accreditation, is irrelevant to how EDGE determines the Base Case, which relies on broader market data rather than supplier-specificinformation.
Reference:EDGE Methodology Report Version 2.0, Section 3.1: Base Case Determination; EDGE User Guide Version 2.1, Section 2.3: Using the EDGE App.
NEW QUESTION # 73
Which of the following protocols should be followed when the project city is not listed in the EDGE App?
Answer: B
Explanation:
The EDGE App relies on location-specific climate data to calculate resource savings, but not all cities are listed. The EDGE User Guide provides guidance for such cases: "If the project city is not listed in the EDGE App, the user should choose the closest city to the project location that is available in the database. If necessary, the user can edit the climate data (e.g., temperature, humidity) to better reflect the project's actual conditions, ensuring accurate calculations" (EDGE User Guide, Section 2.2: Project Setup). Option B, choose the closest city and edit the climate data if necessary, directly matches this protocol. Option A (write to EDGE Certifier and wait) is incorrect, as this is not a required step: "Users are not required to request new cities; they can proceed by selecting the closest city" (EDGE User Guide, Section 2.2: Project Setup). Option C(select any city in the same climate zone globally) is too broad and inaccurate: "Choosing a city from a different region, even in the same climate zone, may lead to incorrect assumptions about local practices and climate" (EDGE Methodology Report Version 2.0, Section 3.2: Climate Data Inputs). Option D (choose the capital city) is also incorrect unless it is the closest: "The capital city should only be selected if it is the nearest available option in the database" (EDGE User Guide, Section 2.2: Project Setup). Thus, the correct protocol is to choose the closest city and edit climate data (Option B).
Reference:EDGE User Guide Version 2.1, Section 2.2: Project Setup; EDGE Methodology Report Version
2.0, Section 3.2: Climate Data Inputs.
NEW QUESTION # 74
......
Our EDGE-Expert practice test material aligns with the content of the actual EDGE EDGE-Expert certification exam. Before making a purchase, you can test the features of our EDGE-Expert Exam Questions with a free demo. By utilizing updated EDGE-Expert Questions, you can easily pass the EDGE-Expert exam on your first attempt. ExamPrepAway has developed its EDGE-Expert exam study material based on feedback from thousands of professionals worldwide.
Latest EDGE-Expert Exam Vce: https://www.examprepaway.com/EDGE/braindumps.EDGE-Expert.ete.file.html
P.S. Free & New EDGE-Expert dumps are available on Google Drive shared by ExamPrepAway: https://drive.google.com/open?id=1ZfhNR9mQmS__OKa6SdmNySX96BOHkHC-