그 외, Fast2test LEED-AP-BD-C 시험 문제집 일부가 지금은 무료입니다: https://drive.google.com/open?id=1OYfEnYlzzTx9Hk8Ljm_uiq0RlcRKgV6e
Fast2test는 전문적인 IT인증시험덤프를 제공하는 사이트입니다.LEED-AP-BD-C인증시험을 패스하려면 아주 현병한 선택입니다. Fast2test에서는LEED-AP-BD-C관련 자료도 제공함으로 여러분처럼 IT 인증시험에 관심이 많은 분들한테 아주 유용한 자료이자 학습가이드입니다. Fast2test는 또 여러분이 원하도 필요로 하는 최신 최고버전의LEED-AP-BD-C문제와 답을 제공합니다.
| Section | Objectives |
|---|---|
| Topic 1: Materials and Resources | - Sustainable material selection and waste reduction
|
| Topic 2: Innovation | - Innovative strategies and exemplary performance
|
| Topic 3: Sustainable Sites | - Site impact mitigation
|
| Topic 4: Location and Transportation | - Site selection and access
|
| Topic 5: Integrative Strategies | - Integrative design process and early project analysis
|
| Topic 6: Regional Priority | - Geographically specific environmental priorities
|
| Topic 7: Energy and Atmosphere | - Energy performance optimization
|
| Topic 8: Indoor Environmental Quality | - Occupant health and comfort
|
| Topic 9: Water Efficiency | - Indoor and outdoor water use reduction
|
>> LEED-AP-BD-C인기자격증 시험대비자료 <<
Fast2test의 제품들은 모두 우리만의 거대한IT업계엘리트들로 이루어진 그룹 즉 관련업계예서 권위가 있는 전문가들이 자기만의 지식과 지금까지의 경험으로 최고의 IT인증관련자료를 만들어냅니다. Fast2test의 문제와 답은 정확도 적중률이 아주 높습니다. 우리의 덤프로 완벽한USGBC인증LEED-AP-BD-C시험대비를 하시면 되겠습니다. 이렇게 어려운 시험은 우리USGBC인증LEED-AP-BD-C덤프로 여러분의 고민과 꿈을 한방에 해결해드립니다.
질문 # 93
The Lakeside Resort is a hotel in a rural area located about 60 mi. (96.6 km) from the nearest town, which has a population of 10,500. There are no other towns for over 200 mi. (321.9 km). The surrounding community is largely made up of ranches and federal- and state-owned land.
The project consists of a single building that includes 150 guest rooms, a small restaurant, an indoor pool, conference spaces, event spaces, and six tenant spaces. A lease has been secured for a future spa, gift shop, coffee shop, and tour operator. Two tenant spaces have not yet been leased. The 10-acre property is adjacent to a lake and provides trail access to public lands.
When drawing the LEED boundary for this project, the project team should include all:
정답:C
설명:
The LEED project boundary must accurately represent the land associated with the certified project rather than an arbitrary setback or nearby destination area. USGBC ' s Minimum Program Requirements specify that the boundary include all contiguous land associated with the project that supports its typical operations. This normally includes the building site, parking, sidewalks, landscaping, stormwater infrastructure, and other project-related features. Option A incorrectly applies a fixed 100-foot extension, which is not a LEED boundary rule. Option B improperly expands the boundary to adjacent attractions merely because occupants may use them. Those lands are not necessarily owned, controlled, or operationally associated with the project.
Therefore, Option C directly reflects LEED ' s reasonable-boundary requirement and avoids both artificial exclusion and inappropriate expansion of the certification boundary.
질문 # 94
A decorative overhead light fixture is specified for a project that costs $1,500 USD and uses recycled water bottles as part of the diffuser shade. The shades are 10% of the overall weight of the fixture and are 50% post-consumer recycled content. Assuming no other portions of the fixture meet sustainability criteria, what would the contributing value of the fixture be?
정답:D
설명:
This option requires the project to calculate the contributing value of the fixture by multiplying the cost of the fixture by the percentage of recycled content by weight1. Since the shades are 10% of the overall weight of the fixture and are 50% post-consumer recycled content, the contributing value of the fixture is:
$1,500 x 10% x 50% = $75
질문 # 95
According to the Integrative Process Credit, the discovery phase of energy-related systems should identify
정답:C
설명:
Explanation
According to the LEED v4 Reference Guide for Building Design and Construction, the discovery phase of energy-related systems should identify ventilation rates, along with other factors such as building orientation, envelope attributes, lighting levels, plug and process loads, and programmatic and operational parameters1.
These factors should be used to create a preliminary "simple box" energy model to evaluate the energy performance of the building and explore potential strategies to reduce energy use1. The other options are not relevant for the discovery phase of energy-related systems. Functional performance tests are part of the implementation phase1. Thermal comfort ranges are related to indoor environmental quality2. Transportation options are related to sustainable sites3. References: IP Credit Integrative Process, LEED v4 Reference Guide for Building Design and Construction4123
질문 # 96
Which of the following projects is eligible to pursue the Energy and Atmosphere Prerequisite, Minimum Energy Performance, Option 2. Prescriptive Compliance: ASHRAE 50% Advanced Energy Design Guide?
정답:C
설명:
The Energy and Atmosphere Prerequisite, Minimum Energy Performance, Option 2. Prescriptive Compliance: ASHRAE 50% Advanced Energy Design Guide allows projects to follow the recommendations of the ASHRAE 50% Advanced Energy Design Guides (AEDGs) for different building types and climate zones. The AEDGs provide design guidance for buildings that use 50% less energy than those built to the requirements of the ANSI/ASHRAE/IES Standard 90.1-2004 commercial code1. However, not all building types and sizes are covered by the AEDGs. According to the LEED Reference Guide for Building Design and Construction2, the following building types and sizes are eligible for this option:
Small to Medium Office buildings up to 100,000 ft2 (9 290 m2)
Medium to Large Retail buildings up to 100,000 ft2 (9 290 m2)
K-12 School buildings up to 200,000 ft2 (18 580 m2)
Warehouse and Distribution Center buildings up to 500,000 ft2 (46 450 m2) Therefore, among the given options, only the school project is eligible to pursue this option, as it falls within the size limit for the K-12 School AEDG3.
References:
LEED Reference Guide for Building Design and Construction v4
Minimum Energy Performance - ASHRAE 90.1 - 2010
ASHRAE 50% Advanced Energy Design Guide for K-12 School Buildings
Advanced Energy Design Guides | Department of Energy
질문 # 97
Massing and orientation in Integrative Process Credit. Integrative Process evaluates how rotating the building
90 degrees affects
정답:D
설명:
Massing and orientation are important factors that affect the energy performance of a building. Massing refers to the shape and size of the building, and orientation refers to the direction that the building faces. By rotating the building 90 degrees, the project team can evaluate how the change in orientation affects the energy loads of the building, such as heating, cooling, and lighting. For example, a building that faces south may receive more solar heat gain and daylight than a building that faces north, which may reduce the need for artificial lighting and heating, but increase the need for cooling and shading. The project team can use the results of the analysis to optimize the massing and orientation of the building to achieve the best energy performance.
LEED V5Reference Guide for Building Design and Construction, Integrative Process Credit: Integrative Process, page 811 Integrative Process Worksheet2
질문 # 98
......
Fast2test덤프를 IT국제인증자격증 시험대비자료중 가장 퍼펙트한 자료로 거듭날수 있도록 최선을 다하고 있습니다. USGBC LEED-AP-BD-C 덤프에는USGBC LEED-AP-BD-C시험문제의 모든 범위와 유형을 포함하고 있어 시험적중율이 높아 구매한 분이 모두 시험을 패스한 인기덤프입니다.만약 시험문제가 변경되어 시험에서 불합격 받으신다면 덤프비용 전액 환불해드리기에 안심하셔도 됩니다.
LEED-AP-BD-C최신 업데이트 시험덤프문제: https://kr.fast2test.com/LEED-AP-BD-C-premium-file.html
BONUS!!! Fast2test LEED-AP-BD-C 시험 문제집 전체 버전을 무료로 다운로드하세요: https://drive.google.com/open?id=1OYfEnYlzzTx9Hk8Ljm_uiq0RlcRKgV6e