What's more, part of that DumpStillValid FlashArray-Implementation-Specialist dumps now are free: https://drive.google.com/open?id=13AgWlFL3xJthwwtU9LH_5XdULg2ef6Lv
To keep the FlashArray-Implementation-Specialist practice questions in Pure Storage PDF format up to date, we regularly update them to according to changes in the real FlashArray-Implementation-Specialist exam content. This dedication to keep Pure Storage Certified FlashArray Implementation Specialist (FlashArray-Implementation-Specialist) exam questions relevant to the FlashArray-Implementation-Specialist actual test domain ensures that customers always get the most up-to-date Pure Storage FlashArray-Implementation-Specialist questions from DumpStillValid.
| Certification Vendor: | Pure Storage |
|---|---|
| Exam Name: | Pure Storage Certified FlashArray Implementation Specialist |
| Exam Number: | FAIS |
| Certificate Validity Period: | 3 years |
| Exam Price: | USD $300 |
| Real Exam Qty: | 75 |
| Available Languages: | English |
| Exam Format: | Multiple Choice (three or four options, one to two correct answers) |
| Related Certifications: | Pure Storage FlashArray Implementation Specialist Certification |
| Exam Duration: | 120 minutes |
| Passing Score: | Not publicly disclosed by Pure Storage |
| Sample Questions: | Pure Storage FlashArray-Implementation-Specialist Sample Questions |
| Exam Way: | Online (proctored via examslocal.com) |
| Pre Condition: | Recommended hands-on experience with Pure Storage FlashArray systems. Targeted at internal Pure Storage Support Specialists, Partner Support Specialists with root level access, and Enterprise or Dark Site customers with root level access. |
| Official Syllabus URL: | https://academy.purestorage.com/student/page/2164533-certification-fais |
>> FlashArray-Implementation-Specialist Certification Exam Dumps <<
We are going to promise that we will have a lasting and sustainable cooperation with customers who want to buy the FlashArray-Implementation-Specialist study materials from our company. We can make sure that our experts and professors will try their best to update the study materials in order to help our customers to gain the newest and most important information about the FlashArray-Implementation-Specialist Exam. If you decide to buy our study materials, you will never miss any important information. In addition, we can promise the updating system is free for you.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
NEW QUESTION # 129
Which PCI cards must be validated on the Bill of Materials (BOM) to allow an Implementation Engineer to attach a DirectFlash Shelf to a FlashArray//XL130R5?
Answer: B
Explanation:
When expanding a Pure Storage FlashArray//XL130 R5 with an external DirectFlash Shelf (DFS), the backend connection between the shelf controllers and the main chassis relies on massive 100GbE bandwidth via the NVMe-oF (RoCE) protocol. Validating the Bill of Materials (BOM) before an onsite installation is a critical preparatory step to ensure the correct internal hardware was shipped to support this connection.
According to the official Pure Storage hardware matrix, the supported PCIe expansion card required for //XL series shelf connectivity is the FA-XL-100G Ethernet/RoCE 2-Port CX6 . This card utilizes the modern Mellanox/Nvidia ConnectX-6 (CX6) chipset, which is explicitly engineered to provide the necessary 100GbE RDMA capabilities to maintain ultra-low latency, NVMe-level speeds across the external storage fabric.
Option B (the CONNECTX-5 card) is an older, End-of-Sale component generally associated with legacy deployments or specific frontend iSCSI requirements, not the modern //XL backend loop. Option C (a 200G CX7 card) is not the standard validated BOM component for a single DFS loop on an //XL130 R5.
Confirming the presence of the 100G CX6 card ensures the engineer has the exact hardware required to successfully cable the 100GbE backend ports.
NEW QUESTION # 130
When installing the first DirectFlash Shelf on a FlashArray//XR2/3, what mezzanine ports are used on the controllers?
Answer: C
Explanation:
When installing the first DirectFlash Shelf (DFS) on a FlashArray//XR2 or //XR3 utilizing the onboard or default mezzanine connectivity, the correct ports to use are ETH6 and ETH9 .
* Hardware Layout: The FlashArray//XR2 and //XR3 utilize a specific Ethernet Mezzanine (EMEZZ) slot for backend connectivity to NVMe-oF shelves. This card typically enumerates its ports as ETH6 through ETH9 (a 4-port configuration).
* Cabling Rule: To maximize physical separation and ensure redundancy across the internal ASIC lanes of the mezzanine card, standard cabling procedures for the first shelf dictate using the outer ports: ETH6 (Port 0) and ETH9 (Port 3).
* Redundancy: This configuration (Port 0 and Port 3) is preferred over using adjacent ports (like 6 and
7) to reduce the risk of a single lane cluster failure affecting both connections to the shelf. The second shelf, if added later, would typically utilize the remaining ports (ETH7 and ETH8).
NEW QUESTION # 131
What is the rack unit height of a FlashArray//XR2/3?
Answer: B
Explanation:
The FlashArray//XR2 and //XR3 (representing the FlashArray//X generation) utilize a standardized 3U (3 Rack Units) chassis form factor.
This 3U chassis is the foundation for the majority of the FlashArray//X line, including the //X10, //X20,
//X50, //X70, and //X90 models. It is designed to be compact while providing sufficient airflow and space for the dual controllers, two data packs (up to 20 DirectFlash Modules), and power/cooling infrastructure.
* Dimensions: Approximately 5.12 inches (13 cm) in height.
* Rack Layout: Implementation Engineers must reserve 3U of contiguous space for the base controller chassis. If expansion shelves are included, they typically require an additional 2U each (for SAS or NVMe shelves).
Option B (4U) is not a standard height for current Pure Storage arrays. Option C (5U) refers to the FlashArray//XL , a larger, performance-optimized platform designed for maximum scale and density, which uses a significantly taller chassis to accommodate more expansion slots and power components. Therefore, for the specified R2/R3 X-series, 3U is the correct height.
NEW QUESTION # 132
On a FlashArray//X50 R2/R3 Fibre Channel (FC) array, what is the default type and placement of the PCIe FC card?
Answer: A
Explanation:
For the FlashArray//X50 R2 and R3 models, the default Fibre Channel (FC) configuration utilizes a 4-port PCIe Fibre Channel card installed in Slot 0 .
The hardware architecture of the FlashArray//X series differentiates slot usage based on the model controller chassis.
* FlashArray//X10 and //X20: These lower-end models utilize Slot 2 for host connectivity (Fibre Channel or iSCSI) because Slots 0 and 1 are typically reserved or occupied by onboard controllers
/mezzanine cards. The standard card for these models is often a 2-port card.
* FlashArray//X50, //X70, and //X90: These mid-to-high-range models feature a different PCIe bus layout. Slot 0 is the primary designated slot for Host I/O connectivity. To support the higher performance capabilities and port density requirements of the X50, Pure Storage defaults to 4-port FC cards (typically 16Gb or 32Gb).
Therefore, identifying the model number is crucial. Since the question specifies the X50 (R2/R3), the correct placement is Slot 0, and the correct card type is the 4-port model. Option A is incorrect because the 2-port card is not the standard default for the performance-tier X50. Option B describes the configuration for an X20, not an X50.
NEW QUESTION # 133
During a FlashArray//X to FlashArray//XL hardware upgrade, when should the Implementation Engineer insert the DFMd modules into the FlashArray//XL?
Answer: B
Explanation:
Upgrading from a FlashArray//X to a FlashArray//XL involves a significant architectural change, often requiring a data migration or a specific "chassis replacement" workflow known as a Data-in-Place upgrade where the new chassis temporarily acts as an expansion shelf. In this specific procedure, the new FlashArray
//XL chassis is not immediately populated with its final drives (DFMDs) before power-on because it first needs to be configured to accept data or join the cluster in a controlled state.
The procedure requires the Implementation Engineer to boot the FlashArray//XL chassis first and configure it into Shelf Mode (SPM) . Only after the chassis is successfully running in this mode-effectively acting as a passive SAS/Ethernet attached shelf to the existing controllers-are the DirectFlash Modules (DFMd) inserted.
Inserting them earlier could cause the array to attempt a full boot sequence or initialize a new array instance, complicating the upgrade logic. By waiting until Shelf Mode is confirmed, the engineer ensures that the modules are recognized correctly as part of the migration target resources, allowing Purity to manage the layout and data redistribution correctly from the source array.
=========
NEW QUESTION # 134
......
New FlashArray-Implementation-Specialist Practice Questions: https://www.dumpstillvalid.com/FlashArray-Implementation-Specialist-prep4sure-review.html
BONUS!!! Download part of DumpStillValid FlashArray-Implementation-Specialist dumps for free: https://drive.google.com/open?id=13AgWlFL3xJthwwtU9LH_5XdULg2ef6Lv