PassTIP를 선택함으로 여러분은 International Code Council 인증93-Tall-Mass-Timber-Buildings시험에 대한 부담은 사라질 것입니다.우리 PassTIP는 끊임없는 업데이트로 항상 최신버전의 International Code Council 인증93-Tall-Mass-Timber-Buildings시험덤프임을 보장해드립니다.만약 덤프품질을 확인하고 싶다면PassTIP 에서 무료로 제공되는International Code Council 인증93-Tall-Mass-Timber-Buildings덤프의 일부분 문제를 체험하시면 됩니다.PassTIP 는 100%의 보장도를 자랑하며International Code Council 인증93-Tall-Mass-Timber-Buildings시험을 한번에 패스하도록 도와드립니다.

International Code Council 93-Tall-Mass-Timber-Buildings Exam Syllabus Topics:

SectionObjectives
Topic 1: Inspection Duties & Documentation- Inspection Reporting and Compliance Verification
- Statement of Special Inspections
Topic 2: Structural & Connection Inspection- Framing and Structural Elements
- Connection Design and Protection
Topic 3: General & Construction Types- Construction Classification — Type IV-A, IV-B, IV-C
  • 1. Allowable Uses and Limitations
    • 2. Height and Area Limitations
      Topic 4: Construction Fire Safety
      Topic 5: Fire-Resistance & Protection- Noncombustible Protection & Encapsulation
      - Concealed Spaces Protection
      - Fire-Resistance-Rated Assemblies
      Topic 6: Mass Timber Materials- CLT, Glulam, NLT, SCL and Engineered Wood Products

      >> 93-Tall-Mass-Timber-Buildings최고기출문제 <<

      시험준비에 가장 좋은 93-Tall-Mass-Timber-Buildings최고기출문제 최신버전 문제

      PassTIP는 많은 IT인사들이International Code Council인증시험에 참가하고 완벽한93-Tall-Mass-Timber-Buildings인증시험자료로 응시하여 안전하게International Code Council 93-Tall-Mass-Timber-Buildings인증시험자격증 취득하게 하는 사이트입니다. Pass4Tes의 자료들은 모두 우리의 전문가들이 연구와 노력 하에 만들어진 것이며.그들은 자기만의 지식과 몇 년간의 연구 경험으로 퍼펙트하게 만들었습니다.우리 덤프들은 품질은 보장하며 갱신 또한 아주 빠릅니다.우리의 덤프는 모두 실제시험과 유사하거나 혹은 같은 문제들임을 약속합니다.PassTIP는 100% 한번에 꼭 고난의도인International Code Council인증93-Tall-Mass-Timber-Buildings시험을 패스하여 여러분의 사업에 많은 도움을 드리겠습니다.

      최신 Special Inspector 93-Tall-Mass-Timber-Buildings 무료샘플문제 (Q67-Q72):

      질문 # 67
      Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?

      정답:D

      설명:
      Option A correctly reflects the required noncombustible protection for protected Type IV-A mass timber.
      Under IBC Section 602.4.1.2.1, the noncombustible protection applied to interior faces of Type IV-A mass timber must contribute the protection time determined by the applicable provisions of Section 722.7, but not less than 80 minutes .
      The broader Type IV provisions are particularly important for interior exit and elevator hoistway enclosures.
      In qualifying tall mass timber buildings with an occupied floor more than 75 feet above the lowest level of fire department access, mass timber interior exit and elevator hoistway enclosures are permitted up to the specified height limits only where protected in accordance with Section 602.4.1.2. For a two-hour, 120- minute-rated enclosure, at least 80 minutes must therefore come from the prescribed noncombustible protection.
      Type IV-B likewise uses an 80-minute minimum for protected interior mass timber, so option B ' s 40-minute value is incorrect. Type IV-C has different exposure allowances and shaft-protection provisions, but option C does not state the controlling tall-building enclosure requirement tested here. Type IV-HT is not governed by the Type IV-A tall mass timber enclosure protection rule.
      References/Topics: 2021 IBC Sections 602.4 and 602.4.1.2 through 602.4.1.2.1; Section 722.7.


      질문 # 68
      Which of the following requires continuous special inspection?

      정답:B

      설명:
      Adhesive anchors installed horizontally to resist sustained tension loads require continuous special inspection.
      Therefore, option D is correct.
      Continuous special inspection means that the special inspector must be present during the performance of the regulated work. This heightened oversight is necessary because horizontal or upwardly inclined adhesive- anchor installations resisting sustained tension are sensitive to installation variables such as borehole cleaning, adhesive proportioning, mixing, placement, embedment depth, temperature, cure time, and prevention of adhesive loss before curing. A concealed installation defect can substantially reduce long-term tension capacity.
      The other listed activities are generally subject to periodic inspection under the mass timber special-inspection provisions. Periodic inspection allows the inspector to observe the work intermittently at appropriate stages rather than remaining present throughout the entire operation. Bolted connections, concealed mass timber connections, and anchorage of mass timber construction to deep foundation systems must still be inspected, but the code does not automatically designate each of those activities as continuous.
      The inspector should also verify installer certification where required, approved adhesive-anchor evaluation documentation, expiration dates, storage conditions, drilling method, hole dimensions, and compliance with the approved structural documents.
      References/Topics: 2021 IBC Sections 1705.3 and 1705.5.3; Table 1705.3; continuous inspection of adhesive anchors under sustained tension.


      질문 # 69
      Refer to the exhibit by clicking on the EXHIBIT button above.


      In the detail shown, which fasteners require fire protection according to AWC Technical Report 10?

      정답:D

      설명:
      The 1/2-inch lag screws attaching the structural steel ledger require fire protection, making option D correct. These fasteners are structural components of the ledger-to-CLT connection and therefore form part of the connection whose fire performance must be maintained for the required duration.
      AWC Technical Report 10 states that wood structural connections-including their connectors, fasteners, and participating members-must be protected from fire exposure for the required fire-resistance time
      . Protection may be provided by wood cover, fire-rated gypsum board, other approved materials, or a combination.
      TR10 distinguishes structural connection fasteners from small fasteners used merely to hold sacrificial protection in place. The report specifically explains that fasteners attaching protective wood strips need not themselves be protected, provided they are sufficiently long to keep the protection in position throughout the required exposure.
      In the illustrated ledger connection, the 1/2-inch lag screws transfer structural load between the steel ledger and CLT wall. Their thermal protection is therefore integral to maintaining connection capacity.
      References/Topics: AWC Technical Report No. 10 Sections 4.5 and connection examples; thermal protection of structural connectors and fasteners.


      질문 # 70
      Periodic special inspection of sealants or adhesives as specified by the International Building Code Section
      703.7 shall be conducted at which of the following locations?

      정답:D

      설명:
      IBC Section 703.7 requires sealant or adhesive to resist air passage at the abutting edges and intersections of mass timber building elements where those elements are required to be fire-resistance rated. Section 1705.20 then requires periodic special inspection where those prescribed sealants or adhesives are installed. Option C repeats that first required location accurately.
      Option D is defective because the code requires sealing at an intersection between mass timber and another material only where both intersecting building elements are required to be fire-resistance rated. The phrase
      "one or the other" materially weakens the condition. Option A is also too broad. A code-defined joint is not automatically subject to Section 703.7; fire-resistant joint systems are separately regulated by Section 715 and, where applicable, Section 1705.18.
      Option B describes the exception in reverse. Sealant or adhesive need not be added under Section 703.7 where it is not a required component of the tested fire-resistance-rated assembly. When it is part of the listed or tested assembly, it must be installed accordingly, but that statement does not identify the primary location requested.
      References/Topics: 2021 IBC Sections 703.7 and 1705.20; sealing of adjacent rated mass timber elements; periodic inspection.


      질문 # 71
      Sealants used to resist passage of air in construction Type IV-A, shall be in accordance with which of the following standards?

      정답:A