有了Fast2test的93-Tall-Mass-Timber-Buildings考古題,即使你只用很短的時間來準備考試,你也可以順利通過考試。因為Fast2test的考古題包含了在實際考試中可能出現的所有問題,所以你只需要記住93-Tall-Mass-Timber-Buildings考古題裏面出現的問題和答案,你就可以輕鬆通過考試。這是通過考試最快的捷徑了。如果你工作很忙實在沒有時間準備考試,但是又想取得93-Tall-Mass-Timber-Buildings的認證資格,那麼,你絕對不能錯過Fast2test的93-Tall-Mass-Timber-Buildings考古題。因為這是你通過考試的最好的,也是唯一的方法。
| Section | Objectives |
|---|---|
| Tall Mass Timber Building Code Provisions | - Fire Safety and Fire Resistance
- Applicable Codes and References
|
>> 93-Tall-Mass-Timber-Buildings資料 <<
擁有International Code Council 93-Tall-Mass-Timber-Buildings認證考試證書可以幫助在IT領域找工作的人獲得更好的就業機會,也將會為成功的IT事業做好鋪墊。
問題 #54
In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:
答案:C
解題說明:
A 7/16-inch wood structural panel does not satisfy the prescribed minimum thickness for fireblocking.
Therefore, option C is the exception.
IBC Section 718.2.1 permits one thickness of 23/32-inch wood structural panel where the joints are properly backed. A 7/16-inch panel is substantially thinner and cannot be substituted without an approved alternative- material determination. The code also recognizes one-half-inch gypsum board and properly installed batts or blankets of mineral wool or other approved materials.
Mass timber complying with Section 2304.11 is also permitted as fireblocking. Its large cross section provides resistance to the movement of flame, hot gases, and smoke through a concealed space that is at least equivalent to the nominal lumber traditionally accepted for this purpose.
The inspector must distinguish fireblocking from a tested firestop system. Fireblocking divides or interrupts concealed combustible cavities; it does not automatically protect a penetration through a fire-resistance-rated wall or floor. Installation must completely fill or close the required space, remain securely supported, and comply with requirements for joints, edges, penetrations, and mineral-fiber compression.
References/Topics: 2021 IBC Section 718.2.1; Section 2304.11; approved fireblocking materials in mass timber construction.
問題 #55
Refer to the exhibit by clicking on the EXHIBIT button above.
If the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, what is the required fire- resistance rating in hours for the structural connections between the glulam and CLT?
答案:A
解題說明:
The structural connections must maintain a fire-resistance rating corresponding to the required rating of the structural elements they connect. Because both the glulam beam and CLT panels require a two-hour fire- resistance rating, their connections must also provide two hours of fire resistance. Therefore, option C is correct.
Concealing steel hardware inside a timber member does not eliminate the fire-resistance requirement. Steel rapidly conducts heat and can lose strength, while timber surrounding a concealed connector can char, split, or withdraw from fasteners. The connection must consequently be protected through sufficient wood cover, noncombustible protection, tested assemblies, or an approved engineering analysis demonstrating acceptable connection temperatures and capacity for the entire required duration.
A three-hour rating is not required merely as a generalized safety factor; the code requires correspondence with the connected elements unless the approved design establishes another condition. A one-hour connection would create a premature weak point in the load path, and a zero-hour rating would be unacceptable simply because the hardware is hidden.
References/Topics: 2021 IBC Section 2304.10.1; fire-resistance rating of mass timber connections; protected concealed steel hardware.
問題 #56
Refer to the figure by clicking on the EXHIBIT button above.

The exterior wall section shown in the Figure provides the prescribed noncombustible protection required by which Construction Type?
答案:A
解題說明:
The illustrated wall corresponds to Type IV-A construction , making option A correct. The key indicator is the extensive Type X gypsum protection provided on the interior face of the CLT wall. Figure 63 shows multiple layers of 5/8-inch Type X gypsum board protecting the interior mass timber, together with the required exterior-side protection.
Type IV-A is the most comprehensively protected of the three tall mass timber construction classifications.
IBC Section 602.4.1.2 requires the interior faces of all mass timber elements , including the inside face of exterior mass timber walls, to be protected with qualifying noncombustible material. Section 602.4.1.2.1 requires the protection contribution to satisfy Table 722.7.1(1) and never be less than 80 minutes. Type IV-A exterior walls also require at least 40 minutes of noncombustible protection on the outside face.
The three interior layers shown are consistent with a heavily protected Type IV-A rated wall. By contrast, Type IV-B permits limited exposed interior mass timber, while Type IV-C expressly permits mass timber interior elements to remain unprotected. Type IV-HT operates under fundamentally different heavy-timber provisions.
References/Topics: 2021 IBC Sections 602.4.1.1, 602.4.1.2 and 602.4.1.2.1; Tables 601 and 722.7.1(1)-(2).
問題 #57
Refer to the exhibit by clicking on the EXHIBIT button above.
In the detail shown, if the connections at the glulam beam and the steel plate required a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire one (1) hour of protection, the minimum required thickness for the wood block member providing protection for the bolt connections is _____ inches.
答案:C
解題說明:
The required minimum wood protection thickness is 1.75 inches , making option B correct. AWC Technical Report No. 10 establishes a thermal-separation methodology for protecting steel connectors and fasteners with sacrificial wood cover. Because the question specifies that the wood cover itself must provide the entire 60- minute fire-protection period, the protection thickness must be calculated using the thermal-separation provisions rather than relying on residual fire resistance from the connector or steel plate.
TR10 applies a reduction to the protection contribution of the base wood layer. Its connection examples use the relationship in Section 4.4.1.3, with the required thermal protection time divided by 0.85. For a 60-minute requirement, back-calculating the prescribed nonlinear wood charring equation gives approximately 1.71 inches of required wood thickness. The practical minimum corresponding to the available choices is therefore
1.75 inches.
The principle is critical for special inspection: steel connection components have high thermal conductivity and must remain below the temperature limits assumed by the connection fire design. The inspector must verify actual wood-cover thickness, fastening, continuity, and any gaps before concealment.
References/Topics: AWC Technical Report No. 10, Sections 4.4.1.3 and 4.5; connection thermal separation; wood protection of steel connectors. TR10 demonstrates the same calculation methodology for wood-covered steel connections.
問題 #58
In mass timber construction of Type IV-C, the fire-resistance ratings of bearing walls are permitted to be reduced by _____ where supporting a roof only.
答案:A
解題說明:
The permitted reduction is one hour. Table 601 assigns a two-hour base fire-resistance rating to exterior and interior bearing walls in Type IV-C construction. Footnote "a" to the table permits the ratings of the primary structural frame and bearing walls to be reduced by one hour where those elements support a roof only.
Accordingly, a Type IV-C bearing wall that supports only roof construction may be assigned a one-hour rating after application of the permitted reduction. The allowance recognizes that the element is not carrying occupied floor levels above and therefore presents a lower consequence of progressive structural failure than a wall supporting one or more floors.
The reduction is not automatic merely because a bearing wall is located at the upper story. The approved structural documents must establish that the wall supports only the roof and does not carry floor loads, transfer loads, elevated mechanical platforms, occupied rooftop structures, or other construction that invalidates the condition.
Options A and B are not reductions specified by Table 601. Option D would eliminate the entire two-hour rating and is not permitted. The inspector should verify the applicable rating and the precise load path before accepting reduced fire protection at the top story.
References/Topics: 2021 IBC Table 601, Footnote "a"; Type IV-C bearing walls and roof-support rating reduction.
問題 #59
......
International Code Council 93-Tall-Mass-Timber-Buildings 認證證書是很多IT人士夢寐以求的。International Code Council 93-Tall-Mass-Timber-Buildings 認證考試是個檢驗IT專業知識和經驗的認證考試,通過考試是需要豐富的IT知識和經驗。為了掌握這麼多知識,一般需要花費大量的時間和精力。Fast2test是個能幫你節約時間和精力的網站,能快速有效地幫助你補充International Code Council 93-Tall-Mass-Timber-Buildings 認證考試的相關知識。如果你對Fast2test感興趣,你可以先在網上免費下載Fast2test提供的部分關於International Code Council 93-Tall-Mass-Timber-Buildings 認證考試的練習題和答案作為嘗試。
93-Tall-Mass-Timber-Buildings學習筆記: https://tw.fast2test.com/93-Tall-Mass-Timber-Buildings-premium-file.html