NewDumps 題庫網承諾所售的 93-Tall-Mass-Timber-Buildings 題庫都是最新,保證順利通過 93-Tall-Mass-Timber-Buildings 考試,取得證書。購買我們考題網的任意一科考試題庫都可以免費試用題庫樣品,讓考生確認購買考試題庫的真實性以及適應考題格式。而且購買了我們的 International Code Council 93-Tall-Mass-Timber-Buildings 考古題的用戶,可以享有一定的折扣優惠和免費更新題庫一年,對于首次參加考試失敗的客戶,憑蓋有考試中心鋼印的考試成績單,將享有退還購買 93-Tall-Mass-Timber-Buildings 考古題的全部費用的福利。
| Section | Objectives |
|---|---|
| Construction Fire Safety | |
| Inspection Duties & Documentation | - Inspection Reporting and Compliance Verification - Statement of Special Inspections |
| General & Construction Types | - Construction Classification — Type IV-A, IV-B, IV-C
|
| Structural & Connection Inspection | - Framing and Structural Elements - Connection Design and Protection |
| Mass Timber Materials | - CLT, Glulam, NLT, SCL and Engineered Wood Products |
| Fire-Resistance & Protection | - Noncombustible Protection & Encapsulation - Concealed Spaces Protection - Fire-Resistance-Rated Assemblies |
>> 最新93-Tall-Mass-Timber-Buildings考古題 <<
獲得93-Tall-Mass-Timber-Buildings認證是IT職業發展有利保证,而NewDumps公司提供最新最準確的93-Tall-Mass-Timber-Buildings題庫資料,幾乎包含真實考試的所有知識點,借助我們的學習資料,您不必浪費時間去閱讀過多的參考書籍,只需要花費一定的時間去學習我們的International Code Council 93-Tall-Mass-Timber-Buildings題庫資料。本站提供PDF版本和軟件本版的93-Tall-Mass-Timber-Buildings題庫,PDF版本的方便打印,而對于軟件版本的International Code Council 93-Tall-Mass-Timber-Buildings題庫可以模擬真實的考試環境,方便考生選擇。
問題 #30
Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?
答案:B
解題說明:
Option A is an exact requirement of the 2021 International Fire Code Section 3303.5 . For Type IV-A, IV- B, and IV-C buildings designed to exceed six stories above grade plane, standpipes must be provided in accordance with IFC Section 3313, unless otherwise approved by the fire code official.
The IFC also requires a water supply for fire department operations, but that supply must be approved by the fire code official and fire chief; the code does not specifically mandate that it be a "portable" water supply.
Option B is therefore incorrect.
The remaining options alter important numerical requirements. Where noncombustible protection is required and construction exceeds six stories, at least one layer , not two, must be installed on applicable building elements more than four levels below active mass timber construction before additional floor levels are erected. Required exterior wall coverings are likewise required more than four levels below active mass timber construction, rather than two.
These safeguards reduce the amount of exposed combustible construction while ensuring that effective fire department infrastructure progresses with the building.
References/Topics: 2021 IFC Section 3303.5; Sections 3313 and related construction-stage fire protection requirements.
問題 #31
Calculated mass timber fire resistance can include each of the following except:
答案:C
解題說明:
Minimum prescriptive dimensions are not themselves a component added into a calculated fire-resistance time. Therefore, option A is the exception.
IBC Section 602.4 states that a mass timber element's required fire resistance can be based on the fire- resistance contribution of the mass timber, the noncombustible protection, or a combination of those two components. Options B, C, and D reflect those permitted approaches.
Minimum dimensions under Section 2304.11 serve a different function. They establish the minimum cross- sectional size and construction characteristics required for qualifying heavy timber or mass timber elements.
A member can satisfy the minimum dimensional requirement without automatically achieving every required one-, two-, or three-hour fire-resistance rating. The structural fire calculation must evaluate the remaining effective section after charring, elevated-temperature effects, applied loading, and any credited protective materials.
The inspector must therefore verify both requirements independently: the installed member must meet the minimum code dimensions and must match the approved fire-resistance design. Increasing a member to the minimum prescriptive size does not by itself replace the required calculation, tested assembly, or approved protection system.
References/Topics: 2021 IBC Sections 602.4, 703.2, 722.7 and 2304.11; calculated mass timber fire resistance.
問題 #32
Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?
答案:A
解題說明:
Option A correctly applies the protection requirements for mass timber used in qualifying interior exit and elevator hoistway enclosures. Where a two-hour, or 120-minute, fire-resistance rating is required, the noncombustible protection must contribute not less than two-thirds of that required rating. Two-thirds of 120 minutes is 80 minutes.
The 2021 IBC provisions for Type IV-A require interior mass timber surfaces to be protected with compliant noncombustible materials. The assigned protection time is determined under Section 722.7 and cannot be less than the applicable minimum. Option B is incorrect because 40 minutes would provide only one-third of a two-hour rating; Type IV-B protected mass timber generally requires at least 80 minutes for a two-hour element. Option C does not correctly describe the special protection path applicable to mass timber exit and hoistway enclosures. Option D is also incorrect because Type IV-HT is not governed by the tall mass timber enclosure provision stated in the question.
The inspector must verify the total assigned protection time, membrane type, number of layers, fastening, joints, corners, penetrations, and continuity on both required faces of the enclosure.
References/Topics: 2021 IBC Sections 602.4, 602.4.1.2 and 722.7.1; protection of mass timber shaft and exit enclosures.
問題 #33
Sealants used to resist passage of air in construction Type IV-A, shall be in accordance with which of the following standards?
答案:B
解題說明:
ASTM C920 is the required standard for sealants used under the IBC mass timber air-sealing provision.
Option C is therefore correct. Section 703.7 applies to Type IV-A construction and requires compliant sealant or adhesive at specified interfaces involving fire-resistance-rated mass timber elements.
The sealing requirement reduces the movement of air, heat, and combustion gases into gaps that could expose additional timber surfaces and undermine the rated performance assumed by the approved design. The sealant must not merely appear to close the opening; it must be the specified product and installed within its approved joint dimensions and substrate conditions.
ASTM A36 is a structural steel material specification. ASTM E119 establishes procedures for fire testing building construction and assemblies but does not qualify elastomeric sealant products. ASTM F1667 covers driven fasteners such as nails, spikes, and staples and has no application to this sealing requirement.
Under Section 1705.20, installation is subject to periodic special inspection where the Section 703.7 sealant is applied. Inspection should occur before concealment and confirm continuity, adhesion, backing, joint depth, surface cleanliness, and compliance with the approved documents.
References/Topics: 2021 IBC Sections 703.7 and 1705.20; Type IV-A construction; ASTM C920.
問題 #34
Given: A special inspector notices on a mass timber building set of drawings a 8 in. x 8 in. solid sawn nominal dimension lumber element.
The design team has recommended the solid sawn member be replaced with an SCL element.
What minimum SCL size would be correct per the International Building Code?
答案:A
解題說明:
The IBC does not require structural composite lumber to retain the same nominal dimensions as the solid- sawn member it replaces. Instead, the minimum finished dimensions are determined from the heavy-timber dimensional equivalency provisions in Section 2304.11.
For a solid-sawn member having nominal dimensions of 8 inches by 8 inches, the corresponding minimum structural composite lumber net dimensions are 7 inches in width by 7-1/2 inches in depth. Therefore, option B is correct. The dimensional conversion recognizes that nominal solid-sawn dimensions differ from actual manufactured dimensions and that SCL products are produced to controlled net dimensions.
The 6-3/4-inch by 8-1/4-inch dimensions in option C correspond to the minimum glued-laminated timber equivalency for an 8-inch-by-8-inch nominal solid-sawn member, not the SCL equivalency. Option D incorrectly assumes that the SCL member must retain the original nominal dimensions, while option A does not match the required equivalency for either SCL or glued-laminated timber.
The substitution must also be approved by the registered design professional because dimensional compliance alone does not establish equivalent structural capacity, connection behavior, fire resistance, or load-path performance.
References/Topics: 2021 IBC Section 2304.11; heavy-timber minimum dimensions; minimum structural composite lumber net-size table.
問題 #35
......