| Section | Objectives |
|---|---|
| Topic 1: Power Systems | - Power distribution principles - UPS systems and backup power |
| Topic 2: Safety and Compliance | - Fire protection systems - Operational safety standards |
| Topic 3: Facility Monitoring and Maintenance | - Fault detection and routine maintenance - Environmental monitoring systems |
| Topic 4: Cooling Systems | - Thermal management and airflow design - Air conditioning systems in data centers |
| Topic 5: Data Center Infrastructure Fundamentals | - Data center architecture overview - IT equipment and facility integration basics |
일반적으로H20-923_V1.0인증시험은 IT업계전문가들이 끊임없는 노력과 지금까지의 경험으로 연구하여 만들어낸 제일 정확한 시험문제와 답들이니. 마침 우리Itexamdump 의 문제와 답들은 모두 이러한 과정을 걸쳐서 만들어진 아주 완벽한 시험대비문제집들입니다. 우리의 문제집으로 여러분은 충분히 안전이 시험을 패스하실 수 있습니다. 우리 Itexamdump 의 문제집들은 모두 100%보장 도를 자랑하며 만약 우리Itexamdump의 제품을 구매하였다면Huawei H20-923_V1.0관련 시험패스와 자격증취득은 근심하지 않으셔도 됩니다. 여러분은 IT업계에서 또 한층 업그레이드 될것입니다.
질문 # 72
The NetEco can be deployed on any virtualization platform.
정답:B
설명:
NetEco is an enterprise management application with specific runtime dependencies, including supported operating system versions, database/middleware compatibility, CPU/memory/storage requirements, and network/security prerequisites. Because of these dependencies, Huawei does not treat NetEco as "hypervisor- agnostic for any virtualization platform." In practice, NetEco deployment in virtualized environments is supported only when the virtualization stack meets Huawei's compatibility requirements, such as validated hypervisors/virtualization solutions, proper virtual hardware settings, and resource reservation rules to ensure stable performance (especially for alarm processing, historical data storage, and northbound integration tasks).
If deployed on an unverified virtualization platform, issues may occur such as clock drift, I/O latency, database performance bottlenecks, unstable NIC behavior, or unsupported VM device models, which can impact data collection, event correlation, and overall system stability. Therefore, the correct interpretation is that NetEco can be deployed onsupported/verifiedvirtualization platforms, not onanyvirtualization platform.
질문 # 73
What is the primary purpose of hot aisle/cold aisle containment in data center cooling design?
정답:B
설명:
Hot aisle/cold aisle containment physically separates cold air supplied to equipment intakes from hot air exhausted from equipment, preventing mixing and recirculation, which significantly improves cooling efficiency and reduces energy waste.
질문 # 74
Which O&M practice is most effective for identifying cooling inefficiency caused by airflow problems in an operating data center?
정답:D
설명:
Huawei facility O&M methods emphasize using monitored operating data to locate inefficiencies before they become faults. Airflow-related cooling inefficiency commonly appears as hot spots at rack inlets, elevated return air temperature fluctuations, abnormal fan speed increases, or uneven temperature distribution across aisles. By trending rack inlet temperature sensors alongside cooling unit supply/return temperatures and fan speed or airflow commands, operations teams can distinguish between insufficient cooling capacity and poor airflow organization. Recirculation (hot air returning to rack inlets) often raises localized inlet temperatures without a proportional rise in room average temperature, while bypass (cold air short-circuiting back to returns) reduces cooling effectiveness and can drive fans to higher speeds unnecessarily. Data-driven checks support targeted corrective actions such as sealing cable openings, adjusting floor tile placement, restoring containment integrity, balancing airflow, or optimizing setpoints. This approach improves thermal stability, prevents overcooling, reduces energy waste, and aligns with Huawei's emphasis on integrated monitoring and closed-loop optimization for reliable, efficient operation.
질문 # 75
The default port number for logging in to the NetEco is
정답:D
설명:
In Huawei NetEco access design, the Web client is reached using HTTPS to protect credentials and management data in transit. During initial deployment and commissioning, engineers access the NetEco login page by entering the server IP address followed by the default HTTPS service port. Huawei's standard login method specifies that users open a browser and enter
https://NetEco server IP:31943 to access the NetEco login interface. This port is therefore treated as the default Web login port in typical on-premises NetEco deployments, and it is the baseline value referenced in installation and login guidance. Other ports may appear in specific tools, customized scenarios, version variants, reverse-proxy deployments, or when security policy requires port changes, but those are exceptions driven by planning or product packaging. For exam and commissioning purposes, the correct default login port is the one used by the NetEco Web client entry point under the standard deployment model: 31943.
질문 # 76
Which of the following statements is false about how to start an electric heater?
정답:C
설명:
Huawei precision cooling logic separates heater enablement into distinct control strategies to avoid unnecessary heating and to keep humidity control stable. In Low temperature heating, the heater is governed purely by the room temperature control demand: if temperature is below the heating threshold (or below setpoint with heating conditions met), the heater can start regardless of whether dehumidification is enabled, which matches statement D. In Dehumidification heating, the heater is not a general low-temperature heater; it is an auxiliary function used to prevent overcooling during dehumidification and to maintain temperature while the unit dehumidifies.
Therefore, the heater in this mode is permitted to start only when the dehumidification function is active and temperature conditions require compensation, which matches statement B. Statement C is false because it incorrectly claims that any of the three selections will start heating automatically whenever room temperature is low; that is not true for "Dehumidification heating" unless dehumidification is actually enabled and running.
질문 # 77
......