| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Maintenance and Operations | 27% | - Medical gas and emergency power systems - Utilities and operational continuity - Building systems: HVAC, electrical, plumbing - Preventive maintenance and asset management |
| Topic 2: Administration | 12% | - Policies, procedures and communication - Leadership and organizational management - Strategic and performance management - Workforce development and safety programs |
| Topic 3: Finance Management | 10% | - Operating and capital budgeting - Deferred maintenance and stewardship - Life-cycle cost analysis - Cost control and financial reporting |
| Topic 4: Compliance | 33% | - Documentation, inspections and corrective actions - Regulatory standards and codes - Emergency preparedness and response - Life safety and fire safety |
| Topic 5: Planning, Design and Construction | 18% | - Construction safety and commissioning - Infection control and risk assessment - Interim life safety measures - Capital project planning and management |
試験に合格したい人は、適切なCHFMガイドの質問を選ぶのが困難です。彼らはどの学習教材が自分に適しているかを知りませんし、どの学習教材が最適であるかを知りません。当社は、当社のCHFM学習教材が世界市場の中で最高であると約束できます。私たちに知られているように、当社のCHFM認定ガイドは、多くの専門家や教授によって設計された当社のCHFM学習教材のこのダイナミックな市場における主要な実践教材です。 CHFM試験問題に頼ることができます!
質問 # 91
What is the required fire rating of a door in a 2-hour rated wall assembly?
正解:B
解説:
NFPA opening-protective tables specify that doors protecting openings in 2-hour fire-resistance-rated fire barriers are required to have a 1-1/2-hour (90-minute) fire protection rating. This distinction between the wall' s fire-resistance rating and the door's fire-protection rating is standard in NFPA 101 and NFPA 80.
References:
NFPA 101: Life Safety Code - Table for opening protective ratings in fire-resistance-rated assemblies.
NFPA 80: Standard for Fire Doors and Other Opening Protectives - Fire door rating requirements for 2-hour barriers.
AHA/CHFM Exam Content Outline - Compliance domain (Life Safety Code requirements).
質問 # 92
According to the AIA standard contract, final approval of shop drawings submitted by suppliers of construction materials is typically the responsibility of the
正解:B
解説:
Per the AIA General Conditions of the Contract for Construction (AIA Document A201), the architect reviews and approves shop drawings, product data, and samples for compliance with design intent and contract documents. The contractor ensures submission and coordination, but final approval authority rests with the architect.
References: AIA A201 - General Conditions of the Contract for Construction; CHFM Candidate Handbook, Planning/Design/Construction domain.
質問 # 93
For a facility to apply the NFPA 101 (2012 edition) standards correctly, which of the following must first be defined?
正解:B
解説:
NFPA 101 (Life Safety Code) is structured around occupancy classifications (healthcare, business, assembly, residential, etc.). Determining the correct occupancy type is the first step because all subsequent requirements-such as egress, fire protection features, and construction criteria-are based on occupancy classification. Construction type, deficiencies, and location are important, but they are addressed only after occupancy is defined.
References: NFPA 101 (2012), Chapters 18/19 (Healthcare Occupancies); CHFM Candidate Handbook - Compliance domain.
質問 # 94
To protect systems and life, GFCI systems monitor which of the following?
正解:C
解説:
A Ground-Fault Circuit Interrupter (GFCI) continuously monitors the current balance between the "hot" and
"neutral" conductors. If an imbalance greater than about 5 milliamps occurs (indicating leakage current flowing to ground), the GFCI trips instantly to protect personnel from shock.
Correct (D): Current - GFCIs detect differences in current between conductors.
Incorrect: Resistance (A), Voltage (B), and Power (C) are not directly monitored by GFCIs.
References:
NFPA 70: National Electrical Code (NEC), Article 100 - GFCI definition.
OSHA Electrical Safety Standards, Subpart S - Requirement for GFCI personnel protection.
AHA/CHFM Exam Content Outline - Compliance domain, electrical safety requirements.
質問 # 95
According to OSHA, which of the following is required as part of a lockout/tagout program?
正解:B
解説:
OSHA's Control of Hazardous Energy (Lockout/Tagout) Standard (29 CFR 1910.147) requires that employers implement a staff training program to ensure all affected employees understand energy control procedures. Insulated tools, logs, or clothing may be used in some contexts, but training is mandatory under OSHA.
References: OSHA 29 CFR 1910.147(c)(7) - Employee Training and Communication.