| Section | Objectives |
|---|---|
| Switchgear Low and Medium Voltage | - Switchgear Section Compartments - Design and Construction - Current Transformers - Metering - Ratings Interlocks - Wiring - Voltage Transformers - LV Switchgear Grounding - Bus Compartment - Electric Tie Breakers - Circuit Breakers - Control Power Transformers - Housing Frames and Enclosure Compartment - Switchgear Compartment Doors - LV AC Switchgear Grounding |
| Terms and Definitions | |
| Examination Methods, Tools and Equipment | - Surface Preparation and Coatings Inspections - Dimensional Inspections - Visual Inspections - Functional Testing - Typical Electrical Testing Techniques |
| Equipment Risk Assessment | - Report Review - Development of a Source Inspection Project Plan - Development of Inspection and Test Plans |
| Electrical Inspection Tools and Test Equipment | |
| Motor Control Centers Low to Medium Voltage | - Ground Bus - Main Isolating Switch - Materials of Construction - Main Feeder Cable Entry Compartment - Circuit Breakers - Enclosures Types - Amp Capacity - Design and Construction Standards |
| Electrical Induction Motors | - Materials of Construction - Motor Testing - Design and Construction Standards |
| Source Inspection Management Program | |
| Liquid-Immersed Transformers | - Design and Construction - Industry Codes and Standards |
| Source Inspection Performance | - Report Writing Nonconformance and Deviations - Review of Project Documents - Inspector Conduct and Safety |
| Electrical Skid Mounted Equipment | - Industry Codes and Standards - Materials of Construction - Cable Support Systems - Purged and Pressurized Equipment in Classified Locations - Equipment Grounding - AC Control Wiring - Electrical Equipment for Hazardous Classified Locations |
성공을 위해 길을 찾고 실패를 위해 구실을 찾지 않는다는 말이 있습니다. API인증 API-SIEE시험이 영어로 출제되어 시험패스가 너무 어렵다 혹은 회사다니느라 공부할 시간이 없다는 등등은 모두 공부하기싫은 구실에 불과합니다. ExamPassdump의 API인증 API-SIEE덤프만 마련하면 실패를 성공으로 바꿀수 있는 기적을 체험할수 있습니다.
질문 # 73
According to IEEE 841, unless otherwise specified, all electrical performance tests shall be conducted in accordance with:
정답:C
설명:
The correct answer isB, IEEE Std 112. IEEE 841 applies to severe-duty, totally enclosed squirrel-cage induction motors used in petroleum and chemical industry service, and when it refers toelectrical performance testing, the standard points toIEEE Std 112as the governing test method unless the purchase specification states otherwise. IEEE Std 112 is the recognized standard for defining methods to determine motor performance characteristics such as efficiency, losses, current, power factor, and related operating behavior during testing.
The other options are not the best answer for this question.NEMA MG-1is a broad motor standard covering design, construction, and application requirements, but it is not the primary referenced document for conducting electrical performance tests in this context.IEEE Std 117relates more to test procedures and acceptance considerations for certain motor categories, but not the default performance-test basis cited here.
IEEE Std 522is associated with insulation testing of form-wound stator coils and windings, not overall motor electrical performance testing.
Therefore, for source inspection of large electric motors, the correct referenced performance-test standard isIEEE Std 112.
질문 # 74
According to NEMA ICS 2, a provision for pad locking shall be provided:
정답:B
설명:
The correct answer isB. UnderNEMA ICS 2for motor controllers and combination starters, the required provision forpadlockingis associated with theexternal operating handle. This arrangement allows the disconnecting means or operating mechanism to be secured in the desired position, typically for safety isolation and lockout purposes during maintenance or inspection. It is a functional safety feature tied directly to operation of the controller, not merely to enclosure access.
The other options are not the standard requirement in this context. Padlocking thedoor,wireway, orrear doormay be used in some installations for security or restricted access, but those are not the specific NEMA ICS 2 provisions identified for the controller operating mechanism itself. The standard intent is to ensure that the operating handle can be locked so the equipment cannot be unintentionally operated while personnel are working on or near it.
From an API source inspection perspective, this falls under verification ofMCC construction details, safety features, interlocks, and compliance with applicable referenced standardsduring shop inspection and quality surveillance. Therefore, the correct answer ison the external operating handle, which makesoption Bthe verified answer.
질문 # 75
Deviations from specifications must be approved by the:
정답:D
설명:
The correct answer isDbecause anydeviation from the approved specification, code requirement, purchase document, or design basismust be formally accepted by theresponsible engineer, not simply by manufacturing, quality, or inspection personnel. In source inspection practice, the manufacturer's engineer may identify or propose a deviation, and the vendor's quality manager may document it within the nonconformance system, but neither of them has final authority to approve a change that affects design intent, technical compliance, or purchaser requirements. The inspection coordinator also manages logistics and communication, but is not the technical approval authority.
This is a fundamental principle in API-aligned source inspection and surveillance. The source inspector verifies conformance to the approved drawings, specifications, and referenced standards. When a deviation is found, it must be handled through the formal deviation or concession process and resolved by the party with technical design responsibility. That is why theresponsible engineeris the correct approving authority. This preserves engineering accountability, maintains traceability, and ensures that any departure from specification is technically evaluated before acceptance. Therefore,option Dis the verified answer.
질문 # 76
What requirement shall be included in a lockout/tagout procedure?
정답:A
질문 # 77
What is the process that aims to find potential defects in a product before it is released for delivery?
정답:B
설명:
The correct answer isAbecauseinspectionis the activity specifically directed at identifying defects, nonconformities, damage, incomplete work, or deviations from specified requirements before the product is accepted and released for shipment or delivery. In the API source inspection context, inspection is a focused verification activity carried out during manufacturing and at final stages to confirm that the equipment conforms to approved drawings, purchase specifications, code requirements, and inspection and test plans. It is therefore the most direct process for finding product defects before handover.
Quality controlis broader than inspection. It includes inspection, testing, review of records, and other operational techniques used to verify product quality.Quality assuranceis even broader and more preventive; it focuses on the quality system, procedures, planning, and confidence that quality requirements will be met.
Examinationis too general and is not the best formal answer in source inspection terminology.
From an API perspective, the source inspector's practical role is to witness, verify, document, and report conformance and nonconformance. That makes inspection the primary defect-finding activity before delivery.