BONUS!!! Download part of LatestCram NRN-522 dumps for free: https://drive.google.com/open?id=1KSP0mBDZz7SMNV4grPgUhbSxHF7eRTW1
Our website provides the most up-to-date and accurate NRN-522 dumps torrent which are the best for passing certification test. It will help you to accelerate your knowledge and improve your professional ability by using our NRN-522 VCE Dumps. We are so proud of helping our candidates go through NRN-522 real exam in their first attempt quickly. The pass rate of our products increased last year because of its reliability.
| Section | Weight | Objectives |
|---|---|---|
| Security and Compliance | 10% | - Security features and procedures
|
| Performance Monitoring and Optimization | 20% | - Performance analysis and optimization
|
| 5G RAN Architecture and Fundamentals | 20% | - 5G RAN logical and physical architecture
|
| Fault Management and Troubleshooting | 25% | - Alarm and fault handling
|
| Network Configuration and Management | 25% | - Software management and upgrades
|
Are you still feeling stressful to the increasing difficulty of the NRN-522 exam? If the answer is yes, you may wish to spend a little time learning our NRN-522 study materials. You will think this is the most correct thing you did for preparing for the NRN-522 Exam. Our NRN-522 exam guide can help you pass the exam more efficiently. Just click to the free demos and you will get the exam questions to have a check!
NEW QUESTION # 108
How do NetAct and the AirScale BTS local Element Manager (Site Manager) typically relate to each other in day-to-day remote operations?
Answer: C
Explanation:
NetAct provides a consolidated, network-wide view of alarms, performance, configuration, and software status for all managed base stations, enabling efficient centralized operations at scale - this is the day-to-day tool for NOC monitoring and bulk provisioning. The BTS Site Manager (Element Manager) complements NetAct by providing detailed, element-specific access for situations requiring deep local diagnostics, such as reviewing local hardware status, logs, or actions not yet reflected centrally, or when central connectivity to a site is degraded. These two tools work together rather than as substitutes for one another. NetAct supports Nokia's Single RAN concept across 2G, 3G, 4G, and 5G technologies on shared hardware, so describing it as
2G/3G-only is incorrect, and the Element Manager is scoped to a single element rather than managing multiple sites network-wide, which is NetAct's role.
NEW QUESTION # 109
After a field engineer replaces an RF unit, the NOC engineer observes that the eCPRI link between the baseband and the new RF unit remains down, even after the cell is unlocked. What should the NOC engineer do first?
Answer: D
Explanation:
When an eCPRI (or CPRI) link remains down immediately following a physical hardware replacement, the most probable and easily verified cause is a physical-layer issue introduced during the replacement itself - such as a fiber connector not being fully seated, an SFP transceiver not properly inserted, a mismatched or faulty SFP module, or an incorrect port connection. Since the field engineer is already on site with direct physical access, the most efficient first step is to ask them to verify these physical connections before the NOC engineer invests time in deeper remote diagnostics, which would be premature given how common and simple physical connection issues are immediately after hardware work. Ordering a new baseband module is a significant escalation that should only follow ruling out simpler causes; locking the cell and closing the ticket would leave the site non-functional; and PLMN ID has no relationship to eCPRI link establishment, which operates at a lower layer entirely unrelated to network identity broadcasting.
NEW QUESTION # 110
A NOC team needs to apply an identical parameter change - updating a neighbor relation threshold - across
200 cells in a region. What NetAct CM capability is best suited to perform this efficiently and consistently?
Answer: B
Explanation:
NetAct's Bulk Configuration Management capability, often referred to as Mass Update, is specifically designed for scenarios where the same configuration change needs to be applied consistently across a large number of network elements or cells. Rather than requiring an engineer to manually access each cell individually - which would be slow, error-prone, and difficult to audit - Bulk CM allows the target parameter, new value, and the set of affected cells to be defined once, with the change then propagated and applied consistently across all selected targets, typically with built-in logging and the ability to verify success or failure per element. This significantly reduces the time required for large-scale changes and ensures consistency, which is particularly important for parameters like neighbor relation thresholds where inconsistent configuration across a cluster could create uneven mobility behavior. Software Management's delivery function addresses SW lifecycle, not parameter changes, and Fault Management is unrelated to configuration provisioning.
NEW QUESTION # 111
A KPI tracks the percentage of established connections or sessions that end abnormally ('dropped') rather than through a normal release procedure. Which KPI category does this belong to?
Answer: C
Explanation:
Retainability KPIs measure whether connections or sessions that have been successfully established remain stable and are terminated through normal procedures, rather than ending abnormally (a 'drop'). A high abnormal release/drop rate indicates retainability problems - subscribers may experience calls or data sessions ending unexpectedly mid-use, significantly impacting user experience even when the initial connection (accessibility) succeeded. This differs from Accessibility, which measures the success of the initial connection attempt; Mobility, which specifically measures handover performance; and Availability, which measures whether a cell or site is in service over time. Retainability degradation can result from radio link failures, interference, transport instability, or hardware issues affecting an already-active connection. NOC engineers monitoring retainability KPIs focus on the stability of in-progress sessions, a key contributor to overall subscriber-perceived quality of service.
NEW QUESTION # 112
What is the key difference between a cell that has been administratively 'locked' (disabled) and a cell that reports 'Out of Service' due to a fault?
Answer: D
Explanation:
'Locked' (administratively disabled) describes a deliberate, controlled state set by an operator or engineer - for example, intentionally taking a cell out of service for planned maintenance, an upgrade, or a configuration change window. This is an expected, reversible action: the cell can be 'unlocked' once the work is complete. 'Out of Service' due to a fault, by contrast, reflects an unintended operational failure - the cell was expected to be operating normally, but a fault condition (such as a hardware, transport, or synchronization issue) has prevented it from doing so, typically accompanied by one or more alarms.
Distinguishing these states matters for NOC engineers: a locked cell appearing down is expected and requires no fault investigation, whereas an unexpectedly out-of-service cell requires diagnosis. Neither state inherently relates to transmit power, and out-of-service conditions are not always due to software upgrades.
NEW QUESTION # 113
......
The pass rate is 98.75% for NRN-522 study materials, and if you choose us, we can ensure you that you can pass the exam just one time. NRN-522 exam dumps are high-quality and high accuracy, since we have a professional team to compile and examine the questions and answers. What’s more, NRN-522 exam materials have both questions and answers, and you can check your answers very conveniently after practicing. We offer you free update for one year for NRN-522 Study Materials, and our system will send the latest version to your email address automatically, and you need to receive and change your learning ways according to the latest version.
Pdf NRN-522 Exam Dump: https://www.latestcram.com/NRN-522-exam-cram-questions.html
DOWNLOAD the newest LatestCram NRN-522 PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1KSP0mBDZz7SMNV4grPgUhbSxHF7eRTW1